← Back
Two family converted from one family
257-24 147 ROAD
QUEENS · Rosedale · BIN 4290532
💬 Discuss this project
1940Year Built
2Stories
B3Building Class
R3XZoning
2,894 sfGross Floor Area
2Units
Rent Stabilized7 Open Violations 5 unresolved · 2 paperwork only ▸FDNY Report ↗
Two family converted from one family · 5,000 sf lot · 0.58 FAR built · Flood zone X500
Locations of Work
Architecture
Cellar3p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MELK1407/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/08/2021$1.2M—— → —$432/sf building
12/24/2019$425K—Private party → INWOOD HOME LLC$147/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CL ENGINEERING P.C.304/14/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
METRO DESIGN CONSULTANTS INC603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NEW FAMILY HOMES & BUILDINGGeneral Contractor303/21/2026
PANTANO LANDSCAPING & CONGeneral Contractor203/21/2026
SUPERIOR PLUMBING & HEATINGPlumbing207/08/2026
POWER SURGE ELECTRIC, INCElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CL ENGINEERING P.C.6781204/14/2021
TRIANGLE INSPECTION & TES7495204/14/2021
Building Lifecycle
All (46)Filed (3)Permit Issued (4)Signed Off (2)Violation (14)Objection (6)Special Inspection (17)
11/25/2025
Violation issued (HPD, open)
I
12/05/2024
Violation issued (HPD, open)
I
11/29/2023
Violation issued (HPD, open)
I
11/01/2023
Violation issued (ECB, open)
Construction
10/24/2023
Violation issued (ECB, open)
Unknown
10/20/2023
Violation issued (ECB, closed)
Construction
11/18/2022
Violation issued (HPD, open)
I
03/17/2022
Violation issued (HPD, open)
I
05/07/2021
Signed off — Alteration
FILED HEREWITH PLUMBING WORK TYPE IN CONJUNCTION WITH DOB ALT-1 APPLICATION # 421943641.
Q00357452-I1
04/20/2021
Special inspection requirement — Maintenance information
CHRISTIAN LOZADA
04/20/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
CHRISTIAN LOZADA
04/20/2021
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
Rajasekhar Sakhamuri
04/20/2021
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
CHRISTIAN LOZADA
04/20/2021
Special inspection requirement — Energy Code Compliance Inspections
CHRISTIAN LOZADA
04/20/2021
Special inspection requirement — HVAC insulation and sealing
CHRISTIAN LOZADA
04/20/2021
Special inspection requirement — HVAC and service water heating equipment
CHRISTIAN LOZADA
04/20/2021
Special inspection requirement — HVAC and service water heating system controls
CHRISTIAN LOZADA
04/14/2021
Filed — Alteration
FILED HEREWITH PLUMBING WORK TYPE IN CONJUNCTION WITH DOB ALT-1 APPLICATION # 421943641.
Q00357452-P1
04/14/2021
Special inspection requirement — Maintenance information
CHRISTIAN LOZADA
04/14/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
CHRISTIAN LOZADA
04/14/2021
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
CHRISTIAN LOZADA
04/14/2021
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
Rajasekhar Sakhamuri
04/14/2021
Special inspection requirement — Energy Code Compliance Inspections
CHRISTIAN LOZADA
04/14/2021
Special inspection requirement — HVAC and service water heating system controls
CHRISTIAN LOZADA
04/14/2021
Special inspection requirement — HVAC and service water heating equipment
CHRISTIAN LOZADA
04/14/2021
Special inspection requirement — HVAC insulation and sealing
CHRISTIAN LOZADA
04/08/2021
Permit issued — Plumbing
Q00357452-I1-PL
04/07/2021
Signed off — Alteration
INSTALLATION OF TEMPORARY CONSTRUCTION FENCE IN CONJUNCTION WITH APPLICATION # 421943641. FENCE SHALL COMPLY WITH CHAPTER 33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
Q00357438-I1
03/15/2021
Permit issued — Construction Fence
Q00357438-I1-FN
03/09/2021
Violation issued (ECB, closed)
Unknown
03/09/2021
Violation issued (ECB, closed)
Unknown
03/09/2021
Violation issued (ECB, closed)
Construction
03/09/2021
Violation issued (ECB, closed)
Construction
12/22/2020
Permit issued — Plumbing
Q00357452-I1-PL
10/20/2020
Objection raised — Other
10/20/2020
Objection resolved — Addressed
10/20/2020
Objection raised — Mechanical
10/20/2020
Objection resolved — Addressed
10/20/2020
Objection raised — Fire_Protection
10/20/2020
Objection resolved — Addressed
10/15/2020
Filed — Alteration
FILED HEREWITH PLUMBING WORK TYPE IN CONJUNCTION WITH DOB ALT-1 APPLICATION # 421943641.
Q00357452-I1
10/05/2020
Permit issued — Construction Fence
Q00357438-I1-FN
10/02/2020
Filed — Alteration
INSTALLATION OF TEMPORARY CONSTRUCTION FENCE IN CONJUNCTION WITH APPLICATION # 421943641. FENCE SHALL COMPLY WITH CHAPTER 33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
Q00357438-I1
06/12/2020
Special inspection requirement — Final
CHRISTIAN LOZADA
01/13/2016
Violation issued (HPD, closed)
C
01/13/2016
Violation issued (HPD, closed)
C
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offSUPERIOR PLUMBING & HEATI04/08/2021
DOB NOWConstruction FenceSigned-offNEW FAMILY HOMES & BUILDI03/15/2021
DOB NOWPlumbingSigned-offSUPERIOR PLUMBING & HEATI12/22/2020
DOB NOWConstruction FenceSigned-offPANTANO LANDSCAPING CON10/05/2020
BIS—ISSUEDNEW FAMILY HOMES & BUILDING03/16/2021
BIS—ISSUEDPANTANO LANDSCAPING & CON11/06/2020
BIS—ISSUEDPANTANO LANDSCAPING & CON10/28/2020
3 projects · most recent 06/24/2024
General Wiring HVAC Wiring
FiledStatusContractorScope
06/24/2024CompleteH & A ELEC'L SERVICES INCHVAC Wiring
05/21/2024CompleteH & A ELEC'L SERVICES INCGeneral Wiring
10/29/2020CompletePOWER SURGE ELECTRIC, INCGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 17
DateRequirementInspectorRole
04/20/2021Maintenance informationCHRISTIAN LOZADAenergy_progress
04/20/2021Fire-Resistant Penetrations and JointsCHRISTIAN LOZADAspecial
04/20/2021Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention FacilitiesRajasekhar Sakhamurispecial
04/20/2021Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationCHRISTIAN LOZADAspecial
04/20/2021Energy Code Compliance InspectionsCHRISTIAN LOZADAprogress
04/20/2021HVAC insulation and sealing CHRISTIAN LOZADAenergy_progress
04/20/2021HVAC and service water heating equipment CHRISTIAN LOZADAenergy_progress
04/20/2021HVAC and service water heating system controls CHRISTIAN LOZADAenergy_progress
04/14/2021Maintenance informationCHRISTIAN LOZADAenergy_progress
04/14/2021Fire-Resistant Penetrations and JointsCHRISTIAN LOZADAspecial
04/14/2021Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationCHRISTIAN LOZADAspecial
04/14/2021Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention FacilitiesRajasekhar Sakhamurispecial
04/14/2021Energy Code Compliance InspectionsCHRISTIAN LOZADAprogress
04/14/2021HVAC and service water heating system controls CHRISTIAN LOZADAenergy_progress
04/14/2021HVAC and service water heating equipment CHRISTIAN LOZADAenergy_progress
04/14/2021HVAC insulation and sealing CHRISTIAN LOZADAenergy_progress
06/12/2020FinalCHRISTIAN LOZADAprogress
▾Documents — 87 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch - Plumbing2
08/15/2026Q00357452-I1Request digital key ↗
08/15/2026Q00357452-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Construction Fence1
08/27/2026Q00357438-I1Request digital key ↗
▸Applications & Permits14
▸BISPLAN / WORK APPROVAL APPLICATION6
03/22/2021421943641Open ↗
10/15/2020421943641Open ↗
10/13/2020421943641Open ↗
Showing 3 of 6 on file for this type
▸BISWORK PERMIT APPLICATION5
06/18/2021421943641Open ↗
11/19/2020421943641Open ↗
11/19/2020421943641Open ↗
Showing 3 of 5 on file for this type
▸BISPARTIAL DEMO: 10-DAY NOTICE (FOR AL/EW-OT PERMITS)1
10/28/2020421943641Open ↗
▸BISPARTIAL DEMO PLAN & DS1 (FOR AL/EW-OT PERMITS)1
10/28/2020421943641Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
03/30/2021421943641Open ↗
▸Zoning, Tax Lot & Property Records6
▸BISZONING DIAGRAM2
10/27/2020421943641Open ↗
10/22/2020421943641Open ↗
▸BISRESTRICTION: RESTRICTIVE DECLARATION1
04/22/2020401117698Open ↗
▸BISVERIFY TAX LOT1
06/10/2021421943641Open ↗
▸BISCO OBJ: VERIFY ADDRESS-TOPO STAMP1
06/10/2021421943641Open ↗
▸BISDOB - ZONING DIAGRAM (ZD1)1
06/15/2020421943641Open ↗
▸Seals & Professional Certifications20
▸DOB NOWProgress Inspector Seal & Signature11
09/01/2026Q00357452-I1Open ↗
09/01/2026Q00357452-I1Open ↗
09/01/2026Q00357452-I1Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
09/01/2026Q00357452-I1Open ↗
09/01/2026Q00357452-I1Open ↗
09/01/2026Q00357452-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/13/2026Q00357438-I1Open ↗
08/13/2026Q00357452-I1Open ↗
08/13/2026Q00357452-P1Open ↗
▸Trade Schedules & Equipment1
▸BISDETECTOR:SMOKE-CERT. OF INSTALLATION1
06/10/2021421943641Open ↗
▸Safety & Tenant Protection2
▸BISSTREET TREE CHECKLIST1
06/15/2020421943641Open ↗
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM1
10/28/2020421943641Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026Q00357452-I1Open ↗
08/13/2026Q00357452-P1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
06/15/2020421943641Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
04/30/2021421943641Open ↗
10/28/2020421943641Open ↗
04/15/2020421943641Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
06/10/2021421943641Open ↗
▸Inspections & Test Reports11
▸BISTECHNICAL REPORT: RESPONSIBILITY9
06/08/2021421943641Open ↗
04/30/2021421943641Open ↗
03/29/2021421943641Open ↗
Showing 3 of 9 on file for this type
▸BISSOIL REPORT1
06/15/2020421943641Open ↗
▸BISTECHNICAL REPORT: SOIL INSPECTION1
06/15/2020421943641Open ↗
▸Approvals, Objections & Sign-offs5
▸BISSCHEDULE A - OCCUPANCY / USE2
06/15/2021421943641Open ↗
04/15/2020421943641Open ↗
▸BISFINAL CONSTRUCTION SIGNOFF1
06/15/2021421943641Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
10/28/2020421943641Open ↗
▸BISSUPERSEDING LETTER1
06/18/2021421943641Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
06/10/2021421943641Open ↗
10/27/2020421943641Open ↗
04/15/2020421943641Open ↗
▸Filing & Intake Forms11
▸BISADDITIONAL INFORMATION7
03/29/2021421943641Open ↗
03/29/2021421943641Open ↗
10/27/2020421943641Open ↗
Showing 3 of 7 on file for this type
▸BISBOROUGH INTAKE FORM3
11/19/2020421943641Open ↗
04/22/2020401117698Open ↗
04/20/2020421943641Open ↗
▸BISEFILING COVER SHEET1
04/20/2020421943641Open ↗
▸Other Documents4
▸BISPLOT DIAGRAM2
06/10/2021421943641Open ↗
04/15/2020421943641Open ↗
▸BISSUSTAINABLE ROOF ZONE FORM1
10/27/2020421943641Open ↗
▸BISCONSTRUCTION - SUPPORTING DOCUMENTATION1
06/15/2021421943641Open ↗