← Back
Predominantly retail with other uses
259 1 AVENUE
MANHATTAN · Gramercy · BIN 1020420
💬 Discuss this project
1910Year Built
4Stories
K4Building Class
C1-6AZoning
5,475 sfGross Floor Area
4Units
Rent Stabilized0 Open Violations
Predominantly retail with other uses · Owner of record: FIRST AVENUE & FIFTEENTH STREET CORP. · 1,460 sf lot · 3.75 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalMechanicalPlumbing
Roof2p · 1 filing · 7 docs
Floor 16p · 2 filings · 11 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
FIRST AVENUE 15TH ST1907/08/2026
PHOENIX SUTTON STR INC903/22/2026
1ST AVE & FIFTEENTHETC103/22/2026
FIRST AVE & 15 CORP103/22/2026
OWNER OF 259 1 AVE103/22/2026
G G 16 RLTY CORP103/22/2026
MSS GOLDEN EAGLE CONSTRUCTION203/21/2026
CHOPSTICK403/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SALVATOR A. CARADONNA JR.302/22/2023
CHERICO KING ARCHITECT, P.C.204/26/2022
GREEN DESIGN306/30/2020
EVAN CHAN ARCHITECT, PC106/15/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ALL IN PERMIT CONSULTANTS303/21/2026
CHERICO KING ARCHITECT P C403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JFZ CONSTRUCTION, INCGeneral Contractor303/21/2026
MATIC CONSTRUCTION CORPGeneral Contractor303/21/2026
PHOENIX SUTTON STR INCGeneral Contractor203/21/2026
AMC PLBG, HTG & CLNG, INCPlumbing207/08/2026
NEPTUNE SIGNS AWNINGSScaffold207/08/2026
TORRES IVANElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CHERICO KING ARCHITECT PC5674204/26/2022
Building Lifecycle
All (60)Filed (9)Permit Issued (7)Signed Off (4)Violation (17)Inspection (4)Objection (2)Special Inspection (17)
01/03/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
11/17/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/28/2023
Signed off — Alteration
ERECT 1 ILLUMINATED ACCESSORY BUSINESS WALL SIGN (NAO*MEDICAL) & 1 NON-ILLUMINATED ACCESSORY BUSINESS WALL SIGN (URGENT CARE AND PRIMARY CARE) ON NON-ILLUM ALUM. PAN BACKGROUND AS PER PLANS FILED HEREWITH.
M08048890-I1
09/28/2023
Signed off — Alteration
ERECT ILLUMINATED ACCESSORY BUSINESS WALL SIGN FOR NAO MEDICAL
M08048851-I1
06/27/2023
Permit issued — Plumbing
M00713204-I1-PL
03/17/2023
Signed off — Alteration
M00355247-I1
02/24/2023
Special inspection requirement — Final
SALVATOR CARADONNA
02/22/2023
Filed — Alteration
ERECT 1 ILLUMINATED ACCESSORY BUSINESS WALL SIGN (NAO*MEDICAL) & 1 NON-ILLUMINATED ACCESSORY BUSINESS WALL SIGN (URGENT CARE AND PRIMARY CARE) ON NON-ILLUM ALUM. PAN BACKGROUND AS PER PLANS FILED HEREWITH.
M08048890-P1
02/15/2023
Special inspection requirement — Final
SALVATOR CARADONNA
01/25/2023
Permit issued — Sign
M08048890-I1-SG
01/25/2023
Permit issued — Sign
M08048851-I1-SG
01/25/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
01/25/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
01/20/2023
Filed — Alteration
ERECT 1 ILLUMINATED ACCESSORY BUSINESS WALL SIGN (NAO*MEDICAL) & 1 NON-ILLUMINATED ACCESSORY BUSINESS WALL SIGN (URGENT CARE AND PRIMARY CARE) ON NON-ILLUM ALUM. PAN BACKGROUND AS PER PLANS FILED HEREWITH.
M08048890-I1
01/20/2023
Filed — Alteration
ERECT ILLUMINATED ACCESSORY BUSINESS WALL SIGN FOR NAO MEDICAL
M08048851-I1
12/02/2022
Special inspection requirement — Final
SALVATOR CARADONNA
07/01/2022
Permit issued — Plumbing
M00713204-I1-PL
06/19/2022
Permit issued — General Construction
M00713192-I1-GC-CX
05/03/2022
Objection resolved — Addressed
04/27/2022
Objection raised — Inspections
04/26/2022
Filed — Alteration
RENOVATE EXISTING COMMERCIAL STORE FOR A NEW MEDICAL OFFICE. INSTALL NEW PLUMBING FIXTURES IN CONJUNCTION WITH APPLICATION# M00713192. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00713204-I1
04/26/2022
Filed — Alteration
IT IS PROPOSED TO RENOVATE EXISTING COMMERCIAL STORE ON 1ST FLOOR FOR A NEW USE GROUP 6B PROFESSIONAL OFFICE FOR AMBULATORY DIAGNOSTIC OR TREATMENT HEALTH CARE. INSTALL NON LOAD BEARING INTERIOR WALLS & HVAC SYSTEM. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00713192-I1
04/26/2022
Special inspection requirement — HVAC-R and service water heating equipment
Cherico King
04/26/2022
Special inspection requirement — HVAC-R and service water heating system controls
Cherico King
04/26/2022
Special inspection requirement — Lighting controls
Cherico King
04/26/2022
Special inspection requirement — Interior lighting power
Cherico King
04/26/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
Cherico King
04/26/2022
Special inspection requirement — Ventilation and air distribution system
Cherico King
04/26/2022
Special inspection requirement — Maintenance information
Cherico King
04/05/2022
Special inspection requirement — Final
LAWRENCE MAREK
04/05/2022
Special inspection requirement — Energy Code Compliance Inspections
Cherico King
04/05/2022
Special inspection requirement — Fire-Resistance Rated Construction
Cherico King
04/05/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Cherico King
04/05/2022
Special inspection requirement — Mechanical Systems
Cherico King
04/05/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Cherico King
04/21/2021
Violation issued (HPD, closed)
I
01/06/2021
Signed off — Alteration
INSTALLATION OF TEMPORARY HEAVY DUTY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE.LIVE LOAD 300PSF.
M00319520-I1
09/02/2020
Violation issued (ECB, closed)
Construction
06/30/2020
Filed — Alteration
INSTALLATION OF TEMPORARY HEAVY DUTY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE.LIVE LOAD 300PSF.
M00319520-P2
06/30/2020
Special inspection requirement — Final
BRIAN T. O'CONNOR
06/15/2020
Filed — Alteration
M00355247-I1
06/15/2020
Permit issued — Construction Fence
M00355247-I1-FN
03/17/2020
Filed — Alteration
INSTALLATION OF TEMPORARY HEAVY DUTY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE.LIVE LOAD 300PSF.
M00319520-P1
02/27/2020
Permit issued — Sidewalk Shed
M00319520-I1-SH
02/21/2020
Filed — Alteration
INSTALLATION OF TEMPORARY HEAVY DUTY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE.LIVE LOAD 300PSF.
M00319520-I1
10/02/2017
Violation issued (ECB, closed)
Construction
11/05/2015
Violation issued (ECB, closed)
Construction
04/08/2010
Violation issued (ECB, closed)
Unknown
03/15/2010
Violation issued (ECB, closed)
Unknown
01/17/2007
Violation issued (ECB, closed)
Construction
09/17/2001
Violation issued (ECB, closed)
Construction
09/17/2001
Violation issued (DOB, closed)
VW*-VIOLATION - WORK W/O PERMIT DISMISSED
09/20/1999
Violation issued (ECB, closed)
Construction
08/29/1995
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/18/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/14/1993
Violation issued (ECB, closed)
Construction
03/18/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/30/1990
Violation issued (ECB, closed)
Boilers
04/10/1990
Violation issued (DOB, closed)
VP*-VIOLATION UNSERVED ECB- DISMISSED
01/09/1989
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offAMC PLBG, HTG & CLNG, INC06/27/2023
DOB NOWSignSigned-offDESTHERS, JOSEPH01/25/2023
DOB NOWSignSigned-offDESTHERS, JOSEPH01/25/2023
DOB NOWPlumbingSigned-offAMC PLBG, HTG & CLNG, INC07/01/2022
DOB NOWGeneral ConstructionPermit IssuedJFZ CONSTRUCTION, INC06/19/2022
DOB NOWConstruction FenceSigned-offMATIC CONSTRUCTION CORP06/15/2020
DOB NOWSidewalk ShedSigned-offPHOENIX SUTTON STR INC02/27/2020
BISPLISSUEDAAA TOTAL PLUMBING, INC03/24/2021
BISMHISSUEDMATIC CONSTRUCTION CORP09/02/2020
BISPLISSUEDAAA TOTAL PLUMBING, INC03/11/2020
BISOTISSUEDGRAND DEVELOPMENT LLC08/22/2017
BISEQISSUEDMSS GOLDEN EAGLE CONSTRUC08/07/2017
BISPLISSUEDORION PLUMBING & HTG CORP01/19/2012
BISOTISSUEDAIRITAN CONSTR CORP12/05/2011
BISOTISSUEDKINGS ASSOCIATES INC06/23/2005
BISEQISSUEDKINGS ASSOCIATES INC06/23/2005
BISFPISSUEDMASTER FIRE SYSTEMS, INC11/18/2004
BISPLISSUEDCHINATOWN PLBG & HTG INC10/17/2001
BISFPISSUEDNEW YORK BUSINESS FIRE SYSTEM IN10/12/2001
BISEQISSUEDCD HOUSING CONSTRUCTION CORP10/11/2001
BISPLISSUEDMAINLAND PLBG09/30/1999
BISFPISSUEDMASTER FIRE PREVENTION SYSTEMS09/24/1999
BISOTISSUEDCENTRAL DEVELOPMENT CORP08/13/1999
BISMHISSUEDSUN SUN CONST. INC07/05/1995
BISOTISSUEDSUN SUN CONST. INC04/07/1995
BISFPISSUEDMASTER FIRE SYSTEMS, INC03/09/1995
BISEQISSUEDSUN SUN CONST. INC02/15/1995
BISPLISSUEDALJER PLBG & HTG CORP01/10/1995
BISOTISSUEDSUN SUN CONST. INC11/14/1994
1 project · most recent 04/26/2022
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
04/26/2022Permit IssuedJFZ CONSTRUCTION, INCHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MODEL# MXZ-4C36NAHZ2 108,000 BTU · Heat Pump Outdoor ×3
1 project · most recent 04/26/2022
Water/Sanitary
FiledStatusContractorScope
04/26/2022Signed-offAMC PLBG, HTG & CLNG, INCWater/Sanitary
5 projects · most recent 03/02/2023
General Wiring
FiledStatusContractorScope
03/02/2023Permit IssuedRAINBOW ELECTRIC CO., INC—
03/02/2023Permit IssuedRAINBOW ELECTRIC CO., INC—
03/01/2021CompleteKWONG MING ELECTRIC INCGeneral Wiring
08/11/2020CompleteKWONG MING ELECTRIC INCGeneral Wiring
02/18/2020CompleteELPO ELECTRICAL CONTG INC—
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
01/03/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
11/17/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/25/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/25/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 17
DateRequirementInspectorRole
02/24/2023FinalSALVATOR CARADONNAprogress
02/15/2023FinalSALVATOR CARADONNAprogress
12/02/2022FinalSALVATOR CARADONNAprogress
04/26/2022HVAC-R and service water heating equipmentCherico Kingenergy_progress
04/26/2022HVAC-R and service water heating system controlsCherico Kingenergy_progress
04/26/2022Lighting controlsCherico Kingenergy_progress
04/26/2022Interior lighting powerCherico Kingenergy_progress
04/26/2022HVAC-R and service water piping design and insulationCherico Kingenergy_progress
04/26/2022Ventilation and air distribution systemCherico Kingenergy_progress
04/26/2022Maintenance informationCherico Kingenergy_progress
04/05/2022FinalLAWRENCE MAREKprogress
04/05/2022Energy Code Compliance InspectionsCherico Kingprogress
04/05/2022Fire-Resistance Rated ConstructionCherico Kingprogress
04/05/2022Fire-Resistant Penetrations and JointsCherico Kingspecial
04/05/2022Mechanical SystemsCherico Kingspecial
04/05/2022Fire-Resistant Penetrations and JointsCherico Kingspecial
06/30/2020FinalBRIAN T. O'CONNORprogress
▾Tenants in the building
TenantSpaceFloorsRenovation projects
NaomedicalMedical / Healthcare—
Project M08048890 Alteration · LOC Issued · 01/20/2023
Read from each project’s drawing title blocks and cover sheets and checked twice; a name appears only when it is the occupant, never the owner, landlord or designer.
▾Documents — 138 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch5
09/02/2026M00713192-I1Request digital key ↗
09/01/2026M08048851-I1Request digital key ↗
09/01/2026M08048890-I1Request digital key ↗
Showing 3 of 5 on file for this type
▸DOB NOWPlans/Sketch - Sidewalk Shed3
09/05/2026M00319520-P1Request digital key ↗
09/05/2026M00319520-I1Request digital key ↗
09/05/2026M00319520-P2Request digital key ↗
▸DOB NOWPlans/Sketch - Construction Fence1
09/04/2026M00355247-I1Request digital key ↗
▸Applications & Permits23
▸BISPLAN / WORK APPROVAL APPLICATION15
11/06/2020123455215Open ↗
10/29/2020123455215Open ↗
08/27/2020123455215Open ↗
Showing 3 of 15 on file for this type
▸BISWORK PERMIT APPLICATION8
09/02/2020123455215Open ↗
03/13/2020123455215Open ↗
11/12/2019123455215Open ↗
Showing 3 of 8 on file for this type
▸Seals & Professional Certifications32
▸DOB NOWDPL-1: Design Professional Seal & Signature9
09/05/2026M00319520-I1Open ↗
09/05/2026M00319520-P2Open ↗
09/05/2026M00319520-P1Open ↗
Showing 3 of 9 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION8
10/28/2019123455215Open ↗
03/29/2019123455215Open ↗
02/07/2019140610257Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWProgress Inspector Seal & Signature7
08/31/2026M08048890-I1Open ↗
08/28/2026M00319520-I1Open ↗
08/28/2026M00713192-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
08/28/2026M00713204-I1Open ↗
08/28/2026M00713192-I1Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
03/03/2017140610257Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
10/05/2011120836747Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
08/04/2017140677818Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
10/03/2011120836747Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
08/04/2017140677818Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
08/04/2017140677818Open ↗
▸Trade Schedules & Equipment10
▸BISSCHEDULE B - PLUMBING5
11/06/2020123455215Open ↗
10/29/2020123455215Open ↗
08/21/2020123455215Open ↗
Showing 3 of 5 on file for this type
▸BISDETECTOR:SMOKE-CERT. OF INSTALLATION1
09/13/2021123455215Open ↗
▸BISSELF-CERT PLUMBING NOTICE1
06/14/2012120836747Open ↗
▸BISEQUIPMENT USE APPLICATION/PERMIT1
09/13/2021123455215Open ↗
▸BISEQUIPMENT USE PERMITS1
09/13/2021123455215Open ↗
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
04/19/2018123455215Open ↗
▸Safety & Tenant Protection6
▸BISTenant Protection Plan and Notes3
11/07/2018123455215Open ↗
04/19/2018123455215Open ↗
03/29/2017140610257Open ↗
▸DOB NOWTenant Protection Plan3
09/05/2026M00319520-I1Open ↗
09/05/2026M00319520-P1Open ↗
09/05/2026M00319520-P2Open ↗
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
09/02/2026M00713192-I1Open ↗
09/01/2026M08048851-I1Open ↗
09/01/2026M08048890-P1Open ↗
Showing 3 of 5 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)3
03/29/2019123455215Open ↗
11/07/2018123455215Open ↗
03/17/2017140610257Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
10/03/2011120836747Open ↗
▸Energy Compliance9
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS5
10/29/2019123455215Open ↗
03/29/2019123455215Open ↗
02/07/2019140610257Open ↗
Showing 3 of 5 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
09/13/2021123455215Open ↗
03/17/2017140610257Open ↗
▸BISTECHNICAL REPORT: ENERGY1
10/05/2011120836747Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
07/13/2021123455215Open ↗
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: RESPONSIBILITY3
07/13/2021123455215Open ↗
08/04/2017140677818Open ↗
03/17/2017140610257Open ↗
▸Approvals, Objections & Sign-offs5
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST4
09/13/2021123455215Open ↗
02/07/2019140610257Open ↗
07/09/2018140610257Open ↗
Showing 3 of 4 on file for this type
▸BISADMINISTRATIVE OBJECTIONS1
10/03/2011120836747Open ↗
▸Cost, Insurance & Ownership9
▸BISCOST AFFIDAVIT9
07/13/2021123455215Open ↗
02/07/2019140610257Open ↗
02/07/2019140610257Open ↗
Showing 3 of 9 on file for this type
▸Filing & Intake Forms23
▸BISADDITIONAL INFORMATION15
04/19/2021123455215Open ↗
11/24/2020123455215Open ↗
11/17/2020123455215Open ↗
Showing 3 of 15 on file for this type
▸BISBOROUGH INTAKE FORM4
02/07/2019140610257Open ↗
07/09/2018140610257Open ↗
04/25/2018140755010Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING COVER SHEET2
04/19/2018123455215Open ↗
10/03/2011120836747Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET2
08/04/2017140677818Open ↗
03/03/2017140610257Open ↗