← Back
One story - permanent living quarter
259-31 148 AVENUE
QUEENS · BIN 4290937
💬 Discuss this project
1940Year Built
2Stories
A2Building Class
R3XZoning
3,036 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
One story - permanent living quarter · Owner of record: ACQUISITION PROPERTIES OF NY LLC · 4,003 sf lot · 0.76 FAR built · Flood zone X500
Locations of Work
ArchitectureMechanical
Floor 23p · 1 filing · 20 docs
Floor 13p · 1 filing · 20 docs
Cellar9p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ACQUISITION PROPERTIES1209/13/2026
ACQUISITION PROPERTIES OF NY LLC903/22/2026
IN GEREBUZZA CONSTRUCTION203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/13/2023$545K—Private party → ACQUISITION PROPERTIES OF NY LLC$180/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CL ENGINEERING P.C.606/24/2026
PETER CHO ARCHITECTS, PLLC105/14/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
METRO DESIGN CONSULTANTS INC1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
GEREBUZZA CONSTRUCTION INGeneral Contractor807/08/2026
INFINITI ESC PLUMBING CORPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
D&E BUILD EVERGREEN I9342606/24/2026
NKM ENGINEERING PLLC6244406/24/2026
TRIANGLE INSPECTION & TES7495203/13/2025
Building Lifecycle
All (66)Filed (7)Permit Issued (6)Signed Off (3)Violation (2)Inspection (8)Objection (40)
08/20/2026
Signed off — ALT-CO - New Building with Existing Elements to Remain
INSTALLATION OF TEMPORARY CONSTRUCTION FENCE IN CONJUNCTION WITH DOB NOW APPLICATION #Q00964019-I1. FENCE SHALL COMPLY WITH CHAPTER 33 OF THE NYC BUILDING CODE.
Q00964019-I1
06/24/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
INSTALLATION OF TEMPORARY CONSTRUCTION FENCE IN CONJUNCTION WITH DOB NOW APPLICATION #Q00964019-I1. FENCE SHALL COMPLY WITH CHAPTER 33 OF THE NYC BUILDING CODE.
Q00964019-P4
05/22/2026
Signed off — ALT-CO - New Building with Existing Elements to Remain
INSTALLATION OF TEMPORARY CONSTRUCTION FENCE IN CONJUNCTION WITH DOB NOW APPLICATION #Q00964019-I1. FENCE SHALL COMPLY WITH CHAPTER 33 OF THE NYC BUILDING CODE.
Q00964019-S2
05/21/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
05/11/2026
Signed off — ALT-CO - New Building with Existing Elements to Remain
INSTALLATION OF TEMPORARY CONSTRUCTION FENCE IN CONJUNCTION WITH DOB NOW APPLICATION #Q00964019-I1. FENCE SHALL COMPLY WITH CHAPTER 33 OF THE NYC BUILDING CODE.
Q00964019-S1
04/14/2026
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
04/07/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
INSTALLATION OF TEMPORARY CONSTRUCTION FENCE IN CONJUNCTION WITH DOB NOW APPLICATION #Q00964019-I1. FENCE SHALL COMPLY WITH CHAPTER 33 OF THE NYC BUILDING CODE.
Q00964019-P3
03/10/2026
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
02/19/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/28/2025
Permit issued — Mechanical Systems
Q00964019-I1-GC-CX
08/28/2025
Permit issued — Construction Fence
Q00964019-S1-FN
06/25/2025
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
06/25/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
06/25/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/25/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
06/20/2025
Permit issued — Plumbing
Q00964019-S2-PL
03/14/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
INSTALLATION OF TEMPORARY CONSTRUCTION FENCE IN CONJUNCTION WITH DOB NOW APPLICATION #Q00964019-I1. FENCE SHALL COMPLY WITH CHAPTER 33 OF THE NYC BUILDING CODE.
Q00964019-P1
03/13/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
INSTALLATION OF TEMPORARY CONSTRUCTION FENCE IN CONJUNCTION WITH DOB NOW APPLICATION #Q00964019-I1. FENCE SHALL COMPLY WITH CHAPTER 33 OF THE NYC BUILDING CODE.
Q00964019-P2
12/10/2024
Violation issued (ECB, closed)
Construction
12/10/2024
Violation issued (ECB, closed)
Construction
09/03/2024
Permit issued — Mechanical Systems
Q00964019-I1-GC-CX
09/03/2024
Permit issued — Foundation
Q00964019-I1-FO-EA
08/30/2024
Permit issued — Construction Fence
Q00964019-S1-FN
08/20/2024
Objection resolved — Addressed
08/19/2024
Objection resolved — Addressed
07/03/2024
Objection raised — Other
06/21/2024
Objection resolved — Addressed
06/21/2024
Objection resolved — Addressed
06/20/2024
Objection raised — Other
06/20/2024
Objection raised — Zoning
06/11/2024
Objection raised — Other
06/11/2024
Objection resolved — Addressed
06/11/2024
Objection resolved — Addressed
06/10/2024
Objection raised — Scope
05/31/2024
Objection raised — Scope
05/24/2024
Objection resolved — Addressed
05/23/2024
Objection raised — Scope
05/23/2024
Objection resolved — Addressed
05/23/2024
Objection raised — Inspections
05/23/2024
Objection resolved — Addressed
05/23/2024
Objection resolved — Addressed
05/20/2024
Objection resolved — Addressed
05/16/2024
Objection raised — Scope
05/16/2024
Objection raised — Zoning
05/14/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
INSTALLATION OF TEMPORARY CONSTRUCTION FENCE IN CONJUNCTION WITH DOB NOW APPLICATION #Q00964019-I1. FENCE SHALL COMPLY WITH CHAPTER 33 OF THE NYC BUILDING CODE.
Q00964019-S2
05/14/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
INSTALLATION OF TEMPORARY CONSTRUCTION FENCE IN CONJUNCTION WITH DOB NOW APPLICATION #Q00964019-I1. FENCE SHALL COMPLY WITH CHAPTER 33 OF THE NYC BUILDING CODE.
Q00964019-S1
05/07/2024
Objection resolved — Addressed
05/07/2024
Objection resolved — Addressed
05/07/2024
Objection resolved — Addressed
05/07/2024
Objection resolved — Addressed
05/07/2024
Objection resolved — Addressed
05/07/2024
Objection resolved — Addressed
05/07/2024
Objection resolved — Addressed
04/17/2024
Objection raised — Energy
04/17/2024
Objection raised — Inspections
04/17/2024
Objection resolved — Addressed
04/17/2024
Objection raised — Structural
04/17/2024
Objection resolved — Addressed
04/17/2024
Objection raised — Admin
04/17/2024
Objection raised — Other
Latest 60 of 66 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedGEREBUZZA CONSTRUCTION IN08/28/2025
DOB NOWConstruction FenceSigned-offGEREBUZZA CONSTRUCTION IN08/28/2025
DOB NOWPlumbingSigned-offINFINITI ESC PLUMBING COR06/20/2025
DOB NOWMechanical SystemsPermit IssuedGEREBUZZA CONSTRUCTION IN09/03/2024
DOB NOWFoundationSigned-offGEREBUZZA CONSTRUCTION IN09/03/2024
DOB NOWConstruction FenceSigned-offGEREBUZZA CONSTRUCTION IN08/30/2024
1 project · most recent 06/24/2026
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
06/24/2026Permit IssuedGEREBUZZA CONSTRUCTION INAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Cooper & Hunter CH-NHPR36LCU 36,000 BTU · Condensing Unit ×2
CH-NHPR48LCU 48,000 BTU · Condensing Unit ×2
CH-RHP24-230VO 24,000 BTU · Condensing Unit ×1
CH-RHP36LCU-230VO 36,000 BTU · Condensing Unit ×1
CH-RHP48LCU-230VO 48,000 BTU · Condensing Unit ×1
Heating
Cooper & Hunter CH-36AHU 36,000 BTU · Ahu ×2
CH-48AHU 48,000 BTU · Ahu ×2
CH-RS24MAHU 24,000 BTU · Ahu ×1
CH-RS36LCAHU 36,000 BTU · Ahu ×1
CH-RS48LCAHU 48,000 BTU · Ahu ×1
Ventilation
Hampton Bay 7114-01 50 CFM · Exhaust Fan ×15
Delta Breeze SMT150 150 CFM · Exhaust Fan ×6
1 project · most recent 06/24/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
06/24/2026Signed-offINFINITI ESC PLUMBING CORGas, Storm, Water/Sanitary
1 project · most recent 04/21/2026
General Wiring
FiledStatusContractorScope
04/21/2026CompleteTRINCITY ELECTRIC, INCGeneral Wiring
1 project · most recent 06/24/2026
Steel Wood
FiledStatusContractorScope
06/24/2026Signed-offGEREBUZZA CONSTRUCTION INSteel, Wood
1 project · most recent 06/24/2026
Fence
FiledStatusContractorScope
06/24/2026Permit IssuedGEREBUZZA CONSTRUCTION INFence
1 project · most recent 06/24/2026
Earthwork
FiledStatusContractorScope
06/24/2026Permit IssuedGEREBUZZA CONSTRUCTION INEarthwork
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
05/21/2026Pass-Final CND-Occupancy InspectionPassView ↗
04/14/2026Pass-Final General Construction Non-Directive 14PassView ↗
03/10/2026Fail-Final General Construction Non-Directive 14FailView ↗
02/19/2026Pass-Final CND-Occupancy InspectionPassView ↗
06/25/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
06/25/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
06/25/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/25/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 82
DateRequirementInspectorRole
07/24/2026Fire-Resistant Penetrations and JointsDanny Chenspecial
07/24/2026Heating SystemsDanny Chenspecial
07/24/2026Concrete - Cast-In-PlaceNARESH MAHANGUspecial
07/24/2026Subsurface Investigations (Borings/Test Pits)Rajasekhar Sakhamurispecial
07/24/2026Structural Steel - DetailsDanny Chenspecial
07/24/2026MasonryDanny Chenspecial
07/24/2026Subgrade InspectionsDanny Chenspecial
07/24/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationDanny Chenspecial
07/24/2026Structural Stability – Alterations of existing buildingsDanny Chenspecial
07/24/2026Structural Steel - High Strength BoltingDanny Chenspecial
07/24/2026Mechanical SystemsDanny Chenspecial
07/24/2026Excavations - Sheeting, Shoring, and BracingDanny Chenspecial
07/24/2026Structural Wood FrameDanny Chenprogress
07/24/2026Footing and FoundationDanny Chenprogress
07/24/2026Energy Code Compliance InspectionsDanny Chenprogress
07/24/2026FinalPETER CHOprogress
07/24/2026Fire-Resistance Rated ConstructionDanny Chenprogress
07/24/2026Duct leakage testing, insulation and designDanny Chenenergy_progress
07/24/2026Fenestration and door U-factor and product ratingsDanny Chenenergy_progress
07/24/2026Insulation placement and R valuesDanny Chenenergy_progress
07/24/2026Air barrier - visual inspectionDanny Chenenergy_progress
07/24/2026HVAC-R and service water heating system controlsDanny Chenenergy_progress
07/24/2026Fenestration areasDanny Chenenergy_progress
07/24/2026Interior lighting powerDanny Chenenergy_progress
07/24/2026Fenestration air leakageDanny Chenenergy_progress
Latest 25 of 82.
▾Documents — 66 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/20/2026Q00964019-S1Request digital key ↗
08/20/2026Q00964019-I1Request digital key ↗
08/20/2026Q00964019-P4Request digital key ↗
Showing 3 of 7 on file for this type
▸Zoning, Tax Lot & Property Records7
▸DOB NOWZD1: DOB Zoning Diagram4
08/20/2026Q00964019-I1Open ↗
08/20/2026Q00964019-P4Open ↗
08/20/2026Q00964019-P3Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWZoning Exhibit form (1-5)2
08/20/2026Q00964019-I1Open ↗
08/20/2026Q00964019-P4Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/20/2026Q00964019-I1Open ↗
▸Seals & Professional Certifications27
▸DOB NOWSpecial Inspector Seal & Signature10
09/02/2026Q00964019-S2Open ↗
09/02/2026Q00964019-S2Open ↗
08/28/2026Q00964019-P4Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWProgress Inspector Seal & Signature10
09/02/2026Q00964019-S2Open ↗
09/02/2026Q00964019-S2Open ↗
08/28/2026Q00964019-P4Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/20/2026Q00964019-I1Open ↗
08/20/2026Q00964019-P4Open ↗
08/20/2026Q00964019-P3Open ↗
Showing 3 of 7 on file for this type
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/20/2026Q00964019-I1Open ↗
08/20/2026Q00964019-P4Open ↗
08/20/2026Q00964019-P3Open ↗
Showing 3 of 6 on file for this type
▸Inspections & Test Reports5
▸DOB NOWSOIL REPORT4
08/20/2026Q00964019-P3Open ↗
08/20/2026Q00964019-I1Open ↗
08/20/2026Q00964019-P4Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q00964019-I1Open ↗
▸Other Documents14
▸DOB NOWSite Survey: Initial4
08/20/2026Q00964019-I1Open ↗
08/20/2026Q00964019-P4Open ↗
08/20/2026Q00964019-P3Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone4
08/20/2026Q00964019-P4Open ↗
08/20/2026Q00964019-P3Open ↗
08/20/2026Q00964019-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProperty Ownership Certification4
08/20/2026Q00964019-P4Open ↗
08/20/2026Q00964019-P3Open ↗
08/20/2026Q00964019-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWFinal Survey1
08/20/2026Q00964019-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026Q00964019-I1Open ↗