| Owner | Filings | Most Recent |
|---|---|---|
| Sumner Place | 16 | 10/14/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 02/28/2023 | $11.0M | — | Private party → AHAVA NOSTRAND, LLC | $688/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| Mark Weinberger Architect | 6 | 10/13/2026 |
| Structural Engineering Technologies | 2 | 03/24/2026 |
| Studio Gallos | 4 | 12/09/2024 |
| EP Engineering | 6 | 09/12/2024 |
| HY PE Structural Engineering | 2 | 02/02/2024 |
| Leon Skvirsky PE | 2 | 09/03/2020 |
| Representative | Filings | Most Recent |
|---|---|---|
| Building Brothers | 4 | 03/21/2026 |
| Expediter Group | 30 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| Park Premium Enterprises | General Contractor | 14 | 07/08/2026 |
| Active Signs | Sign hanger | 2 | 07/08/2026 |
| A. M. Plumbing Company | Plumbing | 1 | 08/06/2026 |
| Metflow Fire Control | Fire Protection | 1 | 07/08/2026 |
| S & J Industrial | Fire Protection | 1 | 08/30/2026 |
| Adrias Plumbing | Plumbing | 1 | 07/08/2026 |
| Francisco A Nunez | Electrical | 1 | 03/21/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| AA Building & Inspection | 1519 | 8 | 10/13/2026 |
| HRF Services | 5616 | 12 | 12/09/2024 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Sprinklers | Permit Issued | S & J Industrial | 08/27/2026 |
| DOB NOW | Plumbing | Permit Issued | A. M. Plumbing Company | 08/05/2026 |
| DOB NOW | Earth Work | Permit Issued | Park Premium Enterprises | 06/30/2026 |
| DOB NOW | Structural | Permit Issued | Park Premium Enterprises | 06/30/2026 |
| DOB NOW | Mechanical Systems | Permit Issued | Park Premium Enterprises | 06/29/2026 |
| DOB NOW | General Construction | Permit Issued | Park Premium Enterprises | 06/29/2026 |
| DOB NOW | General Construction | Signed-off | Park Premium Enterprises | 07/09/2024 |
| DOB NOW | Sprinklers | Signed-off | Metflow Fire Control | 04/03/2024 |
| DOB NOW | Mechanical Systems | Signed-off | Park Premium Enterprises | 03/20/2024 |
| DOB NOW | Foundation | Signed-off | Park Premium Enterprises | 02/23/2024 |
| DOB NOW | Structural | Signed-off | Park Premium Enterprises | 02/07/2024 |
| DOB NOW | General Construction | Permit Issued | Park Premium Enterprises | 01/31/2024 |
| DOB NOW | Plumbing | Signed-off | Adrias Plumbing | 01/19/2024 |
| DOB NOW | Sign | Signed-off | Active Signs | 09/28/2020 |
| DOB NOW | Sign | Signed-off | Active Signs | 09/28/2020 |
| BIS | OT | ISSUED | Paul M Maintenance | 04/18/2016 |
| BIS | — | ISSUED | National Maintenance | 10/01/2007 |
| BIS | MH | ISSUED | Sant James Mechanical | 01/29/2004 |
| BIS | — | ISSUED | Ultimate Signs & Designs Co | 09/12/2003 |
| BIS | — | ISSUED | Ultimate Signs & Designs Co | 08/26/2003 |
| BIS | — | ISSUED | Ultimate Signs & Designs Co | 08/26/2003 |
| BIS | — | ISSUED | Tru-Art Sign Co | 01/18/2000 |
| BIS | — | ISSUED | North Shore Neon Sign Co | 01/14/2000 |
| BIS | — | ISSUED | Tru-Art Sign Co | 01/14/2000 |
| BIS | — | ISSUED | North Shore Neon Sign Co | 01/14/2000 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 10/13/2026 | Permit Issued | Park Premium Enterprises | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Samsung AM096HCVGFS/AA 92,000 BTU · Vrf Outdoor ×1 Mitsubishi Electric MXZ-3C30NA2 27,400 BTU · Heat Pump Outdoor ×1 MXZ-4C36NA2 34,400 BTU · Heat Pump Outdoor ×1 Ventilation Greenheck ×2 Mitsubishi Electric LGH-F470RVX2-E 470 CFM · Erv ×1 |
| 12/09/2024 | Signed-off | Park Premium Enterprises | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Mitsubishi Electric PUHY-EP120TNU-A 240,000 BTU · Vrf Outdoor ×4 PUHY-EP96TNU-A 216,000 BTU · Vrf Outdoor ×2 PURY-EP120TNU-A 216,000 BTU · Vrf Outdoor ×2 PURY-EP168TNU-A 168,000 BTU · Vrf Outdoor ×2 PUZ-A18NKA7 18,000 BTU · Heat Pump Outdoor ×2 Ventilation Renewaire LE-6XJRTV 3,505 CFM · Erv ×2 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 12/09/2024 | Signed-off | Metflow Fire Control | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 12/09/2024 | Signed-off | Adrias Plumbing | Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/11/2024 | Complete | Metro Electrical Contractors | General Wiring |
| 07/03/2024 | Complete | Power Direct Electric | — |
| 06/20/2024 | Cancelled | Village Electl Contractors | — |
| 09/03/2020 | Cancelled | Rainbow Electric Co | — |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/13/2026 | Permit Issued | S & J Industrial | Concrete |
| 12/09/2024 | Signed-off | Metro Fire Control | Steel, Concrete, Masonry |
| Date | Type | Result | Report |
|---|---|---|---|
| 08/18/2026 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 06/26/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 11/21/2024 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 08/05/2024 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 08/05/2024 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 08/05/2024 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 05/10/2024 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 02/15/2024 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 01/30/2024 | Pass-Final PL - Underground | Pass | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 10/07/2026 | Maintenance information | Younes Abouyaala | energy_progress |
| 10/07/2026 | Fire-Resistant Penetrations and Joints | Younes Abouyaala | special |
| 10/07/2026 | Heating Systems | Younes Abouyaala | special |
| 10/07/2026 | Mechanical Systems | Younes Abouyaala | special |
| 10/07/2026 | Post-installed Anchors | Younes Abouyaala | special |
| 10/07/2026 | Energy Code Compliance Inspections | Younes Abouyaala | progress |
| 10/07/2026 | Final | NAVEEN KUMAR | progress |
| 10/07/2026 | HVAC-R and service water heating system controls | Younes Abouyaala | energy_progress |
| 10/07/2026 | HVAC-R and service water heating equipment | Younes Abouyaala | energy_progress |
| 10/07/2026 | HVAC-R and service water piping design and insulation | Younes Abouyaala | energy_progress |
| 10/07/2026 | Shutoff dampers | Younes Abouyaala | energy_progress |
| 09/24/2026 | HVAC-R and service water heating system controls | Younes Abouyaala | energy_progress |
| 09/24/2026 | Energy Code Compliance Inspections | Younes Abouyaala | progress |
| 09/24/2026 | Sprinkler Systems | Younes Abouyaala | special |
| 09/24/2026 | Fire-Resistant Penetrations and Joints | Younes Abouyaala | special |
| 09/24/2026 | HVAC-R and service water piping design and insulation | Younes Abouyaala | energy_progress |
| 09/24/2026 | Maintenance information | Younes Abouyaala | energy_progress |
| 09/24/2026 | HVAC-R and service water heating equipment | Younes Abouyaala | energy_progress |
| 09/01/2026 | Energy Code Compliance Inspections | Younes Abouyaala | progress |
| 09/01/2026 | Sprayed fire-resistant materials | Younes Abouyaala | special |
| 09/01/2026 | Fire-Resistant Penetrations and Joints | Younes Abouyaala | special |
| 09/01/2026 | Exterior lighting power | Younes Abouyaala | energy_progress |
| 09/01/2026 | Interior lighting power | Younes Abouyaala | energy_progress |
| 09/01/2026 | Lighting controls | Younes Abouyaala | energy_progress |
| 09/01/2026 | Maintenance information | Younes Abouyaala | energy_progress |
| Tenant | Space | Floors | Renovation projects |
|---|---|---|---|
| Ahava Medical & Rehabilitation Center | Medical / Healthcare | Cellar, Floor 1, Roof | Project B00965996 |