← Back
BuildNYC
One story retail building
2593 NOSTRAND AVENUE
BROOKLYN · Midwood · BIN 3209582
💬 Discuss this project
1931Year Built
1Stories
K1Building Class
R4Zoning
16,000 sfGross Floor Area
1Units
2 Active Violations ▸FDNY Report ↗
One story retail building · Owner of record: Ahava Nostrand · 23,100 sf lot · 0.69 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionCivilGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Permit Issued — active, not yet Signed-off
RoofAhava Medical & Rehabilitation CenterUnder Construction99p · 3 filings · 20 docs
BulkheadAhava Medical & Rehabilitation Center2p · 1 filing · 20 docs
Floor 1Ahava Medical & Rehabilitation CenterUnder Construction117p · 5 filings · 20 docs
CellarAhava Medical & Rehabilitation CenterUnder Construction99p · 3 filings · 20 docs
Site & exteriorAhava Medical & Rehabilitation CenterUnder Construction40p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Sumner Place1610/14/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/28/2023$11.0M—Private party → AHAVA NOSTRAND, LLC$688/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Mark Weinberger Architect610/13/2026
Structural Engineering Technologies203/24/2026
Studio Gallos412/09/2024
EP Engineering609/12/2024
HY PE Structural Engineering202/02/2024
Leon Skvirsky PE209/03/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Building Brothers403/21/2026
Expediter Group3003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Park Premium EnterprisesGeneral Contractor1407/08/2026
Active SignsSign hanger207/08/2026
A. M. Plumbing CompanyPlumbing108/06/2026
Metflow Fire ControlFire Protection107/08/2026
S & J IndustrialFire Protection108/30/2026
Adrias PlumbingPlumbing107/08/2026
Francisco A NunezElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AA Building & Inspection1519810/13/2026
HRF Services56161212/09/2024
Building Lifecycle
All (147)Filed (22)Permit Issued (15)Signed Off (8)Violation (9)Inspection (9)Objection (54)Special Inspection (30)
10/13/2026
Filed — Alteration CO
PROPOSED MECHANICAL PLANS FILED HEREWITH.
B01363403-P2
10/12/2026
Filed — Alteration CO
PROPOSED MECHANICAL PLANS FILED HEREWITH.
B01363403-P3
10/07/2026
Special inspection requirement — Energy Code Compliance Inspections
Younes Abouyaala
10/07/2026
Special inspection requirement — Mechanical Systems
Younes Abouyaala
10/07/2026
Special inspection requirement — Maintenance information
Younes Abouyaala
10/07/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Younes Abouyaala
10/07/2026
Special inspection requirement — Shutoff dampers
Younes Abouyaala
10/07/2026
Special inspection requirement — Final
NAVEEN KUMAR
10/07/2026
Special inspection requirement — Post-installed Anchors
Younes Abouyaala
10/07/2026
Special inspection requirement — HVAC-R and service water heating equipment
Younes Abouyaala
10/07/2026
Special inspection requirement — HVAC-R and service water heating system controls
Younes Abouyaala
10/07/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Younes Abouyaala
10/07/2026
Special inspection requirement — Heating Systems
Younes Abouyaala
09/24/2026
Special inspection requirement — Energy Code Compliance Inspections
Younes Abouyaala
09/24/2026
Special inspection requirement — HVAC-R and service water heating equipment
Younes Abouyaala
09/24/2026
Special inspection requirement — HVAC-R and service water heating system controls
Younes Abouyaala
09/24/2026
Special inspection requirement — Sprinkler Systems
Younes Abouyaala
09/24/2026
Special inspection requirement — Maintenance information
Younes Abouyaala
09/24/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Younes Abouyaala
09/24/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Younes Abouyaala
09/22/2026
Objection resolved — Addressed
09/15/2026
Objection raised — Cost
09/01/2026
Filed — Alteration CO
PROPOSED MECHANICAL PLANS FILED HEREWITH.
B01363403-P1
09/01/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Younes Abouyaala
09/01/2026
Special inspection requirement — Insulation placement and R values
Younes Abouyaala
09/01/2026
Special inspection requirement — Maintenance information
Younes Abouyaala
09/01/2026
Special inspection requirement — Sprayed fire-resistant materials
Younes Abouyaala
09/01/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
Younes Abouyaala
09/01/2026
Special inspection requirement — Fire-Resistance Rated Construction
Younes Abouyaala
09/01/2026
Special inspection requirement — Fenestration areas
Younes Abouyaala
09/01/2026
Special inspection requirement — Energy Code Compliance Inspections
Younes Abouyaala
09/01/2026
Special inspection requirement — Air barrier - visual inspection
Younes Abouyaala
09/01/2026
Special inspection requirement — Fenestration air leakage
Younes Abouyaala
09/01/2026
Special inspection requirement — Lighting controls
Younes Abouyaala
09/01/2026
Special inspection requirement — Interior lighting power
Younes Abouyaala
08/27/2026
Permit issued — Plumbing
B01363403-S1-EW-SP
08/18/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/05/2026
Permit issued — Plumbing
B01363403-S1-PL
06/30/2026
Permit issued — Earth Work
B01363403-S5-FO-EA
06/30/2026
Permit issued — Structural
B01363403-S6-ST
06/29/2026
Permit issued — Mechanical Systems
B01363403-S2-MS
06/29/2026
Permit issued — General Construction
B01363403-I1-GC
04/17/2026
Objection resolved — Resolved
04/16/2026
Objection resolved — Resolved
04/16/2026
Objection resolved — Resolved
04/15/2026
Objection resolved — Resolved
04/15/2026
Objection resolved — Resolved
04/15/2026
Objection resolved — Resolved
04/15/2026
Objection resolved — Resolved
04/13/2026
Objection resolved — Addressed
04/03/2026
Objection raised — Admin
03/31/2026
Objection raised — Structural
03/31/2026
Objection raised — Admin
03/31/2026
Objection raised — Structural
03/27/2026
Objection raised — Admin
03/25/2026
Objection resolved — Addressed
03/24/2026
Filed — Alteration CO
PROPOSED MECHANICAL PLANS FILED HEREWITH.
B01363403-S6
03/23/2026
Filed — Alteration CO
PROPOSED MECHANICAL PLANS FILED HEREWITH.
B01363403-S5
03/19/2026
Objection raised — Energy
03/19/2026
Objection raised — Energy
Latest 60 of 147 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersPermit IssuedS & J Industrial08/27/2026
DOB NOWPlumbingPermit IssuedA. M. Plumbing Company08/05/2026
DOB NOWEarth WorkPermit IssuedPark Premium Enterprises06/30/2026
DOB NOWStructuralPermit IssuedPark Premium Enterprises06/30/2026
DOB NOWMechanical SystemsPermit IssuedPark Premium Enterprises06/29/2026
DOB NOWGeneral ConstructionPermit IssuedPark Premium Enterprises06/29/2026
DOB NOWGeneral ConstructionSigned-offPark Premium Enterprises07/09/2024
DOB NOWSprinklersSigned-offMetflow Fire Control04/03/2024
DOB NOWMechanical SystemsSigned-offPark Premium Enterprises03/20/2024
DOB NOWFoundationSigned-offPark Premium Enterprises02/23/2024
DOB NOWStructuralSigned-offPark Premium Enterprises02/07/2024
DOB NOWGeneral ConstructionPermit IssuedPark Premium Enterprises01/31/2024
DOB NOWPlumbingSigned-offAdrias Plumbing01/19/2024
DOB NOWSignSigned-offActive Signs09/28/2020
DOB NOWSignSigned-offActive Signs09/28/2020
BISOTISSUEDPaul M Maintenance04/18/2016
BIS—ISSUEDNational Maintenance10/01/2007
BISMHISSUEDSant James Mechanical01/29/2004
BIS—ISSUEDUltimate Signs & Designs Co09/12/2003
BIS—ISSUEDUltimate Signs & Designs Co08/26/2003
BIS—ISSUEDUltimate Signs & Designs Co08/26/2003
BIS—ISSUEDTru-Art Sign Co01/18/2000
BIS—ISSUEDNorth Shore Neon Sign Co01/14/2000
BIS—ISSUEDTru-Art Sign Co01/14/2000
BIS—ISSUEDNorth Shore Neon Sign Co01/14/2000
2 projects · most recent 10/13/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
10/13/2026Permit IssuedPark Premium EnterprisesHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Samsung AM096HCVGFS/AA 92,000 BTU · Vrf Outdoor ×1
Mitsubishi Electric MXZ-3C30NA2 27,400 BTU · Heat Pump Outdoor ×1
MXZ-4C36NA2 34,400 BTU · Heat Pump Outdoor ×1
Ventilation
Mitsubishi Electric LGH-F470RVX2-E 470 CFM · Erv ×1
12/09/2024Signed-offPark Premium EnterprisesHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric PUHY-EP120TNU-A 240,000 BTU · Vrf Outdoor ×4
PUHY-EP96TNU-A 216,000 BTU · Vrf Outdoor ×2
PURY-EP120TNU-A 216,000 BTU · Vrf Outdoor ×2
PURY-EP168TNU-A 168,000 BTU · Vrf Outdoor ×2
PUZ-A18NKA7 18,000 BTU · Heat Pump Outdoor ×2
Ventilation
Renewaire LE-6XJRTV 3,505 CFM · Erv ×2
1 project · most recent 12/09/2024
Sprinkler System
FiledStatusContractorScope
12/09/2024Signed-offMetflow Fire ControlSprinkler System
1 project · most recent 12/09/2024
Water/Sanitary
FiledStatusContractorScope
12/09/2024Signed-offAdrias PlumbingWater/Sanitary
4 projects · most recent 09/11/2024
General Wiring
FiledStatusContractorScope
09/11/2024CompleteMetro Electrical ContractorsGeneral Wiring
07/03/2024CompletePower Direct Electric—
06/20/2024CancelledVillage Electl Contractors—
09/03/2020CancelledRainbow Electric Co—
2 projects · most recent 10/13/2026
Concrete Steel Masonry
FiledStatusContractorScope
10/13/2026Permit IssuedS & J IndustrialConcrete
12/09/2024Signed-offMetro Fire ControlSteel, Concrete, Masonry
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
08/18/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/26/2025Pass-Final CND-Occupancy InspectionPassView ↗
11/21/2024Pass-Final CND-Occupancy InspectionPassView ↗
08/05/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
08/05/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
08/05/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
05/10/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/15/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/30/2024Pass-Final PL - UndergroundPassView ↗
▾Special Inspection Requirements (DOB NOW) — 150
DateRequirementInspectorRole
10/07/2026Maintenance informationYounes Abouyaalaenergy_progress
10/07/2026Fire-Resistant Penetrations and JointsYounes Abouyaalaspecial
10/07/2026Heating SystemsYounes Abouyaalaspecial
10/07/2026Mechanical SystemsYounes Abouyaalaspecial
10/07/2026Post-installed AnchorsYounes Abouyaalaspecial
10/07/2026Energy Code Compliance InspectionsYounes Abouyaalaprogress
10/07/2026FinalNAVEEN KUMARprogress
10/07/2026HVAC-R and service water heating system controlsYounes Abouyaalaenergy_progress
10/07/2026HVAC-R and service water heating equipmentYounes Abouyaalaenergy_progress
10/07/2026HVAC-R and service water piping design and insulationYounes Abouyaalaenergy_progress
10/07/2026Shutoff dampersYounes Abouyaalaenergy_progress
09/24/2026HVAC-R and service water heating system controlsYounes Abouyaalaenergy_progress
09/24/2026Energy Code Compliance InspectionsYounes Abouyaalaprogress
09/24/2026Sprinkler SystemsYounes Abouyaalaspecial
09/24/2026Fire-Resistant Penetrations and JointsYounes Abouyaalaspecial
09/24/2026HVAC-R and service water piping design and insulationYounes Abouyaalaenergy_progress
09/24/2026Maintenance informationYounes Abouyaalaenergy_progress
09/24/2026HVAC-R and service water heating equipmentYounes Abouyaalaenergy_progress
09/01/2026Energy Code Compliance InspectionsYounes Abouyaalaprogress
09/01/2026Sprayed fire-resistant materialsYounes Abouyaalaspecial
09/01/2026Fire-Resistant Penetrations and JointsYounes Abouyaalaspecial
09/01/2026Exterior lighting powerYounes Abouyaalaenergy_progress
09/01/2026Interior lighting powerYounes Abouyaalaenergy_progress
09/01/2026Lighting controlsYounes Abouyaalaenergy_progress
09/01/2026Maintenance informationYounes Abouyaalaenergy_progress
Latest 25 of 150.
▾Tenants in the building
TenantSpaceFloorsRenovation projects
Ahava Medical & Rehabilitation CenterMedical / HealthcareCellar, Floor 1, Roof
Project B00965996 Alteration CO · LOC Issued · 12/05/2023
Names are taken automatically from the text of each project’s filed documents (title blocks and cover sheets) and screened to exclude owners, landlords and designers. They may be incomplete or wrong; check the filing.
▾Documents — 164 on file (BIS + DOB NOW)
▸Plans & Drawings19
▸DOB NOWPlans/Sketch17
08/24/2026B01067525-I1Request digital key ↗
08/24/2026B00965996-S4Request digital key ↗
08/24/2026B00965996-P5Request digital key ↗
Showing 3 of 17 on file for this type
▸DOB NOWPlans/Sketch - Sign2
09/02/2026B00391673-I1Request digital key ↗
09/02/2026B00391674-I1Request digital key ↗
▸Applications & Permits4
▸BISPLAN / WORK APPROVAL APPLICATION3
12/01/2016321083091Open ↗
02/25/2015321083091Open ↗
02/25/2015321083091Open ↗
▸BISWORK PERMIT APPLICATION1
04/21/2016321083091Open ↗
▸Zoning, Tax Lot & Property Records4
▸DOB NOWHouse Number Verification: TOPO Stamp2
08/13/2026B01363403-I1Open ↗
08/13/2026B00965996-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026B01363403-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/13/2026B01363403-I1Open ↗
▸Seals & Professional Certifications84
▸DOB NOWProgress Inspector Seal & Signature34
10/13/2026B01363403-P3Open ↗
10/13/2026B01363403-P3Open ↗
10/13/2026B01363403-P3Open ↗
Showing 3 of 34 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature25
10/13/2026B01363403-P3Open ↗
10/05/2026B01363403-P1Open ↗
10/05/2026B01363403-P2Open ↗
Showing 3 of 25 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature20
10/13/2026B01363403-P3Open ↗
09/02/2026B00391673-I1Open ↗
09/02/2026B00391674-I1Open ↗
Showing 3 of 20 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
02/25/2015321083091Open ↗
02/25/2015321083091Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
12/21/2016321083091Open ↗
12/21/2016321083091Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
02/25/2015321083091Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING1
02/25/2015321083091Open ↗
▸Safety & Tenant Protection7
▸DOB NOWStreet Tree Checklist4
08/13/2026B00965996-P4Open ↗
08/13/2026B01363403-I1Open ↗
08/13/2026B00965996-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWStreet Tree Sign Off1
08/13/2026B00965996-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026B00965996-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026B00965996-I1Open ↗
▸Environmental & Asbestos21
▸DOB NOWDEP ACP-5: Asbestos Assessment Report20
10/13/2026B01363403-P3Open ↗
08/18/2026B01363403-S1Open ↗
08/18/2026B01363403-S2Open ↗
Showing 3 of 20 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
02/25/2015321083091Open ↗
▸Energy Compliance4
▸DOB NOWPreliminary Commissioning Report Certification2
08/13/2026B00965996-S2Open ↗
08/13/2026B00965996-S1Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
12/21/2016321083091Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
12/21/2016321083091Open ↗
▸Inspections & Test Reports4
▸DOB NOWTR4 Test Report and Plot Diagram2
08/18/2026B01363403-S5Open ↗
08/13/2026B00965996-S5Open ↗
▸DOB NOWSOIL REPORT2
08/18/2026B01363403-S5Open ↗
08/13/2026B00965996-S5Open ↗
▸Approvals, Objections & Sign-offs1
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
12/21/2016321083091Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
12/21/2016321083091Open ↗
02/25/2015321083091Open ↗
02/25/2015321083091Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET2
02/25/2015321083091Open ↗
02/25/2015321083091Open ↗
▸Other Documents10
▸DOB NOWProperty Ownership Certification4
08/13/2026B00965996-P5Open ↗
08/13/2026B00965996-P4Open ↗
08/13/2026B00965996-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWAdjoining Owners Notification2
08/18/2026B01363403-S5Open ↗
08/13/2026B00965996-S5Open ↗
▸DOB NOWPlot Diagram2
08/18/2026B01363403-S5Open ↗
08/13/2026B01363403-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026B01363403-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026B01363403-I1Open ↗