← Back
Two stories - detached, small or mid-size
26-27 200 STREET
QUEENS · Auburndale · BIN 4487500
💬 Discuss this project
1940Year Built
2Stories
A1Building Class
R2AZoning
3,117 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 7,000 sf lot · 0.45 FAR built · Flood zone X
Locations of Work
StructuralPlumbing
Floor 11 filing · 18 docs
Site & exterior1p · 1 filing · 7 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/28/2014$808K—— → —$259/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FANG ARCHITECT212/06/2021
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
3T GC LLCGeneral Contractor303/21/2026
CATMAN PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
FANG ARCHITECT5513212/06/2021
TRIANGLE INSPECTION & TES7495112/06/2021
Building Lifecycle
All (24)Filed (2)Permit Issued (2)Signed Off (1)Inspection (7)Special Inspection (12)
02/27/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
02/24/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/24/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
02/22/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
01/09/2023
Signed off — Alteration
PLUMBING WORK FOR GARAGE IN CONJUNCTION WITH NB JOB #Q00611444.
Q00612992-I1
01/05/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
11/22/2022
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
06/21/2022
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
03/03/2022
Permit issued — Plumbing
Q00612992-I1-PL
02/18/2022
Permit issued — Structural
Q00611444-I1-GC-CX
12/06/2021
Filed — Alteration
PLUMBING WORK FOR GARAGE IN CONJUNCTION WITH NB JOB #Q00611444.
Q00612992-I1
10/15/2021
Filed — New Building
Q00611444-I1
10/15/2021
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
DEZHANG FANG
10/15/2021
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
Rajasekhar Sakhamuri
10/15/2021
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Rajasekhar Sakhamuri
10/13/2021
Special inspection requirement — Concrete - Cast-In-Place
DEZHANG FANG
10/13/2021
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
DEZHANG FANG
10/13/2021
Special inspection requirement — Masonry
DEZHANG FANG
10/13/2021
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Rajasekhar Sakhamuri
10/13/2021
Special inspection requirement — Energy Code Compliance Inspections
DEZHANG FANG
10/13/2021
Special inspection requirement — Fire-Resistance Rated Construction
DEZHANG FANG
10/13/2021
Special inspection requirement — Final
DEZHANG FANG
10/13/2021
Special inspection requirement — Footing and Foundation
DEZHANG FANG
10/13/2021
Special inspection requirement — Interior lighting power
DEZHANG FANG
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offCATMAN PLUMBING INC03/03/2022
DOB NOWStructuralPermit Issued3T GC LLC02/18/2022
BIS—ISSUED3T GC LLC01/19/2022
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
02/27/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/24/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/24/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
02/22/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/05/2023Pass-Final CND-Occupancy InspectionPassView ↗
11/22/2022Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
06/21/2022Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
10/15/2021Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationDEZHANG FANGspecial
10/15/2021Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention FacilitiesRajasekhar Sakhamurispecial
10/15/2021Subsurface Investigations (Borings/Test Pits)Rajasekhar Sakhamurispecial
10/13/2021Concrete - Cast-In-PlaceDEZHANG FANGspecial
10/13/2021Excavations - Sheeting, Shoring, and BracingDEZHANG FANGspecial
10/13/2021MasonryDEZHANG FANGspecial
10/13/2021Subsurface Investigations (Borings/Test Pits)Rajasekhar Sakhamurispecial
10/13/2021Energy Code Compliance InspectionsDEZHANG FANGprogress
10/13/2021Fire-Resistance Rated ConstructionDEZHANG FANGprogress
10/13/2021FinalDEZHANG FANGprogress
10/13/2021Footing and FoundationDEZHANG FANGprogress
10/13/2021Interior lighting powerDEZHANG FANGenergy_progress
▾Documents — 37 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/27/2026Q00611444-I1Request digital key ↗
08/26/2026Q00612992-I1Request digital key ↗
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
10/07/2021421792956Open ↗
▸BISWORK PERMIT APPLICATION1
05/26/2022421792956Open ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026Q00611444-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q00611444-I1Open ↗
▸Seals & Professional Certifications9
▸DOB NOWSpecial Inspector Seal & Signature5
08/27/2026Q00612992-I1Open ↗
08/27/2026Q00612992-I1Open ↗
08/27/2026Q00612992-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
08/23/2026Q00611444-I1Open ↗
08/23/2026Q00611444-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026Q00612992-I1Open ↗
08/13/2026Q00611444-I1Open ↗
▸Trade Schedules & Equipment1
▸DOB NOWStandpipe Alarms Drawings1
08/27/2026Q00611444-I1—
▸Safety & Tenant Protection4
▸BISEXCAVATION OR DEMOLITION: 5-DAY NOTICE1
05/26/2022421792956Open ↗
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM1
05/26/2022421792956Open ↗
▸BISSRO MD ANTI-HARASSMENT CHECKLIST1
05/26/2022421792956Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026Q00611444-I1Open ↗
▸Environmental & Asbestos1
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
05/26/2022421792956Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026Q00611444-I1Open ↗
▸Inspections & Test Reports5
▸DOB NOWTR4 Test Report and Plot Diagram2
08/13/2026Q00612992-I1Open ↗
08/13/2026Q00611444-I1Open ↗
▸DOB NOWSOIL REPORT2
08/13/2026Q00612992-I1Open ↗
08/13/2026Q00611444-I1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/13/2026Q00611444-I1Open ↗
▸Approvals, Objections & Sign-offs2
▸BISLETTERS - SUPPORTING DOCUMENTATION2
05/26/2022421792956Open ↗
05/26/2022421792956Open ↗
▸Cost, Insurance & Ownership1
▸BISPROJECT-SPECIFIC GL INSURANCE1
05/26/2022421792956Open ↗
▸Filing & Intake Forms3
▸BISADDITIONAL INFORMATION1
05/26/2022421792956Open ↗
▸BISBOROUGH INTAKE FORM1
05/26/2022421792956Open ↗
▸BISEFILING COVER SHEET1
10/07/2021421792956Open ↗
▸Other Documents4
▸DOB NOWAdjoining Owners Notification1
08/13/2026Q00611444-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/13/2026Q00611444-I1Open ↗
▸DOB NOWFinal Survey1
08/13/2026Q00611444-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026Q00611444-I1Open ↗