| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 04/06/2022 | $999K | — | Private party → Private party | $400/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| HT ASSOCIATES | 5 | 12/02/2024 |
| JOHN C. CHEN ARCHITECT,PLLC | 3 | 12/14/2022 |
| Representative | Filings | Most Recent |
|---|---|---|
| HAOTIAN & ASSOCIATES INC. | 4 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| HT BUILDS LLC | General Contractor | 7 | 07/08/2026 |
| SPLEN CONSTRUCTION INC | General Contractor | 7 | 07/08/2026 |
| KLE CONSTRUCTION INC | General Contractor | 6 | 03/21/2026 |
| VILLAGE P & H NY INC | Plumbing | 2 | 07/08/2026 |
| ROBIN ELECTRICAL CO., INC | Electrical | 1 | 03/22/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| FLUSHING ENGINEERING SERV | 4373 | 4 | 12/02/2024 |
| JOHN C CHEN ARCHITECT, PL | 2205 | 3 | 10/07/2024 |
| BUILDING CONSULTING ENGIN | 1034 | 1 | 11/11/2022 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | General Construction | Signed-off | HT BUILDS LLC | 09/20/2024 |
| DOB NOW | Construction Fence | Signed-off | HT BUILDS LLC | 03/01/2024 |
| DOB NOW | Mechanical Systems | Permit Issued | HT BUILDS LLC | 02/27/2024 |
| DOB NOW | Plumbing | Signed-off | VILLAGE P & H NY INC | 11/28/2023 |
| DOB NOW | Earth Work | Permit Issued | KLE CONSTRUCTION INC | 03/02/2023 |
| DOB NOW | Construction Fence | Signed-off | KLE CONSTRUCTION INC | 03/02/2023 |
| DOB NOW | Plumbing | Signed-off | VILLAGE P & H NY INC | 11/22/2022 |
| DOB NOW | Curb Cut | Signed-off | SPLEN CONSTRUCTION INC | 11/10/2022 |
| DOB NOW | Earth Work | Permit Issued | SPLEN CONSTRUCTION INC | 11/09/2022 |
| DOB NOW | Construction Fence | Signed-off | SPLEN CONSTRUCTION INC | 10/21/2022 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 12/02/2024 | Signed-off | HT BUILDS LLC | Air Conditioning Systems, Heating Systems | Cooling Goodman GSX140361 6 tons · Condensing Unit ×4 Bryant 113ANA036-J 6 tons · Heat Pump Outdoor ×4 Heating A.O. Smith PCG-75-400 75,100 BTU · Water Heater ×4 Weil-Mclain CGA-5-SPIND 140,000 BTU · Boiler ×2 Williamson GWA-166-N-T 140,000 BTU · Boiler ×2 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/01/2024 | Complete | ROBIN ELECTRICAL CO., INC | General Wiring |
| 12/21/2022 | Complete | ROBIN ELECTRICAL CO., INC | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 12/02/2024 | Signed-off | HT BUILDS LLC | Steel, Concrete, Masonry, Wood |
| Date | Type | Result | Report |
|---|---|---|---|
| 11/06/2024 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 10/25/2024 | Fail-Final General Construction Non-Directive 14 | Fail | View ↗ |
| 10/04/2024 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 08/28/2024 | Pass-Final Curb Cut Non-Directive 14 | Pass | View ↗ |
| 12/22/2023 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 09/29/2023 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 09/29/2023 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 09/29/2023 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 09/27/2023 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 12/02/2024 | Concrete - Cast-In-Place | KY FU | special |
| 12/02/2024 | Metering | KY FU | energy_progress |
| 12/02/2024 | HVAC-R and service water heating system controls | KY FU | energy_progress |
| 12/02/2024 | Air barrier - visual inspection | KY FU | energy_progress |
| 12/02/2024 | Insulation placement and R values | KY FU | energy_progress |
| 12/02/2024 | Electric vehicle service equipment requirements | KY FU | energy_progress |
| 12/02/2024 | Air barrier — testing | KY FU | energy_progress |
| 12/02/2024 | HVAC-R and service water heating equipment | KY FU | energy_progress |
| 12/02/2024 | Fenestration air leakage | KY FU | energy_progress |
| 12/02/2024 | Ventilation and air distribution system | KY FU | energy_progress |
| 12/02/2024 | Permanent certificate | KY FU | energy_progress |
| 12/02/2024 | Fenestration and door U-factor and product ratings | KY FU | energy_progress |
| 12/02/2024 | HVAC-R and service water piping design and insulation | KY FU | energy_progress |
| 12/02/2024 | Interior lighting power | KY FU | energy_progress |
| 12/02/2024 | Fenestration areas | KY FU | energy_progress |
| 12/02/2024 | Maintenance information | KY FU | energy_progress |
| 12/02/2024 | Footing and Foundation | KY FU | progress |
| 12/02/2024 | Fire-Resistance Rated Construction | KY FU | progress |
| 12/02/2024 | Final | KY FU | progress |
| 12/02/2024 | Energy Code Compliance Inspections | KY FU | progress |
| 12/02/2024 | Subgrade Inspections | KY FU | special |
| 12/02/2024 | Structural Steel - Details | KY FU | special |
| 12/02/2024 | Structural Stability – Alterations of existing buildings | KY FU | special |
| 12/02/2024 | Structural Cold-Formed Steel | KY FU | special |
| 12/02/2024 | Mechanical Systems | KY FU | special |