ECB10/20/2020FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES: NOTED: OBSERVED THE FACADE AT EXPOSURE #1 WITH CRACKS AND DETERIORATION. EAST SIDE OF EXPOSURE #1 THE FACADE IS BULGING. THE STEEL CLADDING WHICH COVERS TH$6K due
DOB04/05/2019VIOLATION ISSUED TO ELEVATOR - FAILURE TO FILE CATEGORY 1 2017 INSPECTION/TEST
DOB11/07/2017V-DOB VIOLATION - ACTIVE
DOB09/15/2017VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2016 INSPECTION/TEST
DOB12/01/2016VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2015 INSPECTION/TEST
DOB06/10/2015VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2014 INSPECTION/TEST
DOB10/31/2014VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2013 INSPECTION/TEST
DOB03/31/2014VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPECTION/TEST
DOB10/01/2012VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2011 INSPECTION/TEST
DOB12/13/2011VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2010 INSPECTION/TEST
DOB10/08/2010V-DOB VIOLATION - ACTIVE
DOB02/27/2009V-DOB VIOLATION - ACTIVE
DOB03/21/2008V-DOB VIOLATION - ACTIVE
DOB04/02/2007V-DOB VIOLATION - ACTIVE
DOB06/10/2004V-DOB VIOLATION - ACTIVE
DOB01/13/1997V-DOB VIOLATION - ACTIVE
ECB09/05/2018FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT FRONT FACADE, SECTION OF STUCCO AND PLYWOOD HAS FALLEN TO SIDEWALK. CRACKED STUCCO OBSERVED THROUGHOUT FRONT EXTERIOR WALL. REM: REPAIR AND/OR RENothing owed — awaiting certificate of correction
ECB07/26/2018FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. NOTED: AT EXTERIOR FRONT WALL, SECITON OF STUCCO AND PLYWOOD HAS FALLEN TO THE SIDEWALK. CRACKED STUCCO OBSERVED THROUGHOUT FRONT EXTERIOR WALL.*OVERHEADNothing owed — awaiting certificate of correction
ECB10/30/2016WORK W/OUT A PERMIT. NOTED: NO DOCUMENT FILED FOR SIDEWALK SHED ERECTION/CONSTRUCTION.Nothing owed — awaiting certificate of correction
ECB09/01/2016FAILURE TO MAINTAIN EXTERIOR BLDG WALL IN THAT AT FRONT FACADE,STUCCO IS CRACKED,BULDGING PIECES ARE LOOSE & SONE HAS FALLEN ONTO SIDEWALK. REMEDY: MAKE SAFE IMMEDIATLY,MAKE ALL NECESSARY REPAIRS,MAINTAIN BLDGNothing owed — awaiting certificate of correction
ECB08/19/201497**05 FAILURE TO MAINTAIN ELEV DEVICE RESPONDENT FAILED ALLOW MANDAT ORY ANNUAL/ROUTINE INSPECTION BY THE DEPARTMENT OR APPROVED AGENCY PER28-304.6.1 & APPENDIX K OF THE BUILDING CODE MULTIPLE ATTEMPTS TO GAINNothing owed — awaiting certificate of correction
ECB09/23/201397**05-FAILURE TO MAINTAIN ELEVATOR DEVICE RESPONDENT FAILED TO ALLOW MANDATORY ANNUAL/ROUTINE INSPECTION BY THE DEPT OR APPROVED AGENCY PER28-304-6-1 & APPENDIX K OF THE BUILDING CODE.MULTIPLE ATTEMPTS TO GAINNothing owed — awaiting certificate of correction
ECB03/27/201397**FAILURE TO MAINTAIN ELEVATOR DEVICE.RESPONDENT FAILED TO PROVIDE PROPER ACCESS IN ORDER THAT THE DEPT CAN PERFORM PERIODIC INSPECTION AS PER 28-304.6 & APPENDIX K OF THE BUILDING CODE,RESPONDENT FAILED TONothing owed — awaiting certificate of correction