← Back
Elevator apt, fireproof with stores
Concern Logan
2602 PITKIN AVENUE · BIN 3430242
💬 Discuss this project
2023Year Built
9Stories
D6Building Class
R7AZoning
51,916 sfGross Floor Area
68Units
0 Open ViolationsFDNY Report ↗
Elevator apt, fireproof with stores · Owner of record: CONCERN LOGAN HOUSING DEVELOPMENT FUND C ORP. · 7,200 sf lot · 7.21 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire Protection
Roof6p · 5 filings · 20 docs
Bulkhead1p · 4 filings · 20 docs
Floor 92p · 3 filings · 15 docs
Floor 82p · 3 filings · 15 docs
Floor 72p · 3 filings · 15 docs
Floor 62p · 3 filings · 15 docs
Floor 52p · 3 filings · 15 docs
Floor 42p · 3 filings · 15 docs
Floor 32p · 3 filings · 15 docs
Floor 2113p · 4 filings · 20 docs
Floor 1120p · 6 filings · 20 docs
Cellar119p · 6 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
VAYA RESTORATION INC703/22/2026
ALBA SERVICES INC503/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/11/2021$4.4M—— → —— not available
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JM ZONING, LLC.3803/21/2026
PATUXENT ENGINEERING1403/21/2026
THE GREEN STUDIO103/21/2026
ECC203/21/2026
KD DESIGNS103/21/2026
W J PROFESSIONAL EXPEDITING COMPANY203/21/2026
S R SOLAR DESIGN203/21/2026
MILLENNIUM DESIGNS103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PENTA RESTORATION CORPGeneral Contractor2007/08/2026
DDS MECHANICAL FPS CORPFire Protection907/08/2026
TRI BOROUGH SCAFFOLDINGGeneral Contractor603/21/2026
MC SUPERSTRUCTURE INCGeneral Contractor507/08/2026
VAYA RESTORATION INCGeneral Contractor507/08/2026
DIMITRIOS VOGIATZISElectrical403/21/2026
MAJOR ELECTRIC INC 003238General Contractor403/22/2026
RL MECHANICAL SERVICESGeneral Contractor407/08/2026
D.D.S. MECH PBG&HTG CORPPlumbing307/08/2026
ARSENAL SCAFFOLD INCGeneral Contractor307/08/2026
ALBA SERVICES INCGeneral Contractor203/21/2026
770 ELECTRIC CORPGeneral Contractor107/08/2026
ACCURATE MECHANICAL INCFire Protection107/08/2026
MAJOR ELECTRIC CORP.Electrical103/22/2026
MKW ASSOCIATESGeneral Contractor103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
METRIC CONSULTING AND INS18032208/17/2026
MCHENERY TESTING LAB9181212/04/2024
NKM ENGINEERING PLLC6244110/31/2024
Building Lifecycle
All (194)Filed (37)Permit Issued (41)Signed Off (18)Inspection (16)Objection (52)Special Inspection (30)
08/18/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
Justin Moses
08/18/2026
Special inspection requirement — Air barrier continuity plan testing
Justin Moses
08/18/2026
Special inspection requirement — Air barrier - visual inspection
Justin Moses
08/18/2026
Special inspection requirement — Metering
Justin Moses
08/18/2026
Special inspection requirement — Energy Code Compliance Inspections
Justin Moses
08/18/2026
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
SAMI HAJJAR P.E
08/18/2026
Special inspection requirement — Lighting controls
Justin Moses
08/18/2026
Special inspection requirement — Maintenance information
Justin Moses
08/18/2026
Special inspection requirement — Lighting in dwelling units
Justin Moses
08/18/2026
Special inspection requirement — Exterior lighting power
Justin Moses
08/18/2026
Special inspection requirement — Fenestration air leakage
Justin Moses
08/18/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
SAMI HAJJAR P.E
08/18/2026
Special inspection requirement — Fire-Resistance Rated Construction
SAMI HAJJAR P.E
08/18/2026
Special inspection requirement — Electrical motors and elevators
Justin Moses
08/18/2026
Special inspection requirement — Masonry
SAMI HAJJAR P.E
08/18/2026
Special inspection requirement — Wall Panels, Curtain Walls, and Veneers
SAMI HAJJAR P.E
08/18/2026
Special inspection requirement — Vestibules
Justin Moses
08/18/2026
Special inspection requirement — Insulation placement and R values
Justin Moses
08/18/2026
Special inspection requirement — Protection of exposed foundation insulation
Justin Moses
08/18/2026
Special inspection requirement — Fenestration areas
Justin Moses
08/18/2026
Special inspection requirement — Interior lighting power
Justin Moses
08/17/2026
Filed — New Building
Plumbing work per plans filed herewith.
B00614012-A6
08/06/2026
Special inspection requirement — Fenestration air leakage
Justin Moses
08/06/2026
Special inspection requirement — Electrical motors and elevators
Justin Moses
08/06/2026
Special inspection requirement — Air barrier continuity plan testing
Justin Moses
08/06/2026
Special inspection requirement — Interior lighting power
Justin Moses
08/06/2026
Special inspection requirement — Air barrier - visual inspection
Justin Moses
08/06/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
Justin Moses
08/06/2026
Special inspection requirement — Insulation placement and R values
Justin Moses
08/06/2026
Special inspection requirement — Lighting in dwelling units
Justin Moses
08/06/2026
Special inspection requirement — Protection of exposed foundation insulation
Justin Moses
07/15/2026
Filed — New Building
Plumbing work per plans filed herewith.
B00614012-A4
12/09/2025
Signed off — Alteration
INSTALLATION OF SOLAR PANELS ON EXISTING ROOF. NO CHANGE IN USE, OCCUPANCY, OR EGRESS. NO CHANGE IN BULK
B01132037-I1
09/30/2025
Objection resolved — Addressed
09/29/2025
Objection raised — Other
09/17/2025
Signed off — New Building
Plumbing work per plans filed herewith.
B00614012-S4
09/17/2025
Signed off — Alteration
B00641125-I1
09/09/2025
Filed — New Building
Plumbing work per plans filed herewith.
B00614012-A3
08/27/2025
Filed — New Building
Plumbing work per plans filed herewith.
B00614012-A2
07/23/2025
Signed off — Alteration
Install combined sprinkler/standpipe system as per plans filed. No change to use, egress or occupancy. Filed in conjunction with NB# B00614012.
B00641108-I1
07/21/2025
Signed off — New Building
Plumbing work per plans filed herewith.
B00614012-S5
07/18/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/09/2025
Signed off — Alteration
FILING FOR SUB-SLAB DEPRESSURIZATION SYSTEM AS PER PLANS FILED HEREWITH. NO CHANGE IN EGRESS, USE OR OCCUPANCY.
B01239332-I1
06/25/2025
Filed — New Building
Plumbing work per plans filed herewith.
B00614012-A1
06/17/2025
Permit issued — General Construction
B01239332-I1-GC
06/13/2025
Filed — Alteration
Install combined sprinkler/standpipe system as per plans filed. No change to use, egress or occupancy. Filed in conjunction with NB# B00614012.
B00641108-P2
06/12/2025
Filed — Alteration
FILING FOR SUB-SLAB DEPRESSURIZATION SYSTEM AS PER PLANS FILED HEREWITH. NO CHANGE IN EGRESS, USE OR OCCUPANCY.
B01239332-I1
06/09/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
06/05/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
05/23/2025
Objection resolved — Addressed
05/15/2025
Filed — New Building
Plumbing work per plans filed herewith.
B00614012-P9
05/12/2025
Permit issued — Standpipe
B00641125-I1-EW-SD
05/09/2025
Permit issued — General Construction
B00614012-I1-GC
05/09/2025
Permit issued — Plumbing
B00614012-S5-PL
05/09/2025
Permit issued — Standpipe
B00641108-I1-EW-SD
05/09/2025
Permit issued — Standpipe
B00641108-I1-EW-SP
04/23/2025
Objection raised — Other
04/23/2025
Objection resolved — Addressed
04/16/2025
Filed — New Building
Plumbing work per plans filed herewith.
B00614012-P7
04/07/2025
Signed off — New Building
Plumbing work per plans filed herewith.
B00614012-S3
Latest 60 of 194 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offPENTA RESTORATION CORP06/17/2025
DOB NOWStandpipeSigned-offDDS MECHANICAL FPS CORP05/12/2025
DOB NOWGeneral ConstructionPermit IssuedPENTA RESTORATION CORP05/09/2025
DOB NOWPlumbingSigned-offD.D.S. MECH PBG&HTG CORP05/09/2025
DOB NOWStandpipeSigned-offDDS MECHANICAL FPS CORP05/09/2025
DOB NOWStandpipeSigned-offDDS MECHANICAL FPS CORP05/09/2025
DOB NOWSprinklersSigned-offACCURATE MECHANICAL INC01/30/2025
DOB NOWMechanical SystemsSigned-offRL MECHANICAL SERVICES01/09/2025
DOB NOWSolarSigned-off770 ELECTRIC CORP11/19/2024
DOB NOWProtection and Mechanical MethodsSigned-offARSENAL SCAFFOLD INC11/07/2024
DOB NOWSupported ScaffoldSigned-offVAYA RESTORATION INC09/25/2024
DOB NOWMechanical SystemsSigned-offRL MECHANICAL SERVICES08/22/2024
DOB NOWFoundationSigned-offPENTA RESTORATION CORP07/03/2024
DOB NOWStructuralSigned-offPENTA RESTORATION CORP06/11/2024
DOB NOWSprinklersSigned-offDDS MECHANICAL FPS CORP05/31/2024
DOB NOWSuspended ScaffoldSigned-offVAYA RESTORATION INC05/31/2024
DOB NOWSuspended ScaffoldSigned-offVAYA RESTORATION INC05/31/2024
DOB NOWSprinklersSigned-offDDS MECHANICAL FPS CORP05/31/2024
DOB NOWStandpipeSigned-offDDS MECHANICAL FPS CORP05/31/2024
DOB NOWSupport of ExcavationSigned-offPENTA RESTORATION CORP05/21/2024
DOB NOWConstruction FenceSigned-offPENTA RESTORATION CORP05/17/2024
DOB NOWPlumbingSigned-offD.D.S. MECH PBG&HTG CORP05/08/2024
DOB NOWGeneral ConstructionPermit IssuedPENTA RESTORATION CORP05/07/2024
DOB NOWSidewalk ShedSigned-offMC SUPERSTRUCTURE INC02/23/2024
DOB NOWMechanical SystemsSigned-offRL MECHANICAL SERVICES11/30/2023
DOB NOWProtection and Mechanical MethodsSigned-offARSENAL SCAFFOLD INC11/24/2023
DOB NOWMechanical SystemsSigned-offRL MECHANICAL SERVICES10/10/2023
DOB NOWSidewalk ShedSigned-offMC SUPERSTRUCTURE INC08/11/2023
DOB NOWSidewalk ShedSigned-offMC SUPERSTRUCTURE INC07/28/2023
DOB NOWFoundationSigned-offPENTA RESTORATION CORP07/05/2023
DOB NOWStructuralSigned-offPENTA RESTORATION CORP06/13/2023
DOB NOWStandpipeSigned-offDDS MECHANICAL FPS CORP06/02/2023
DOB NOWSprinklersSigned-offDDS MECHANICAL FPS CORP06/01/2023
DOB NOWSprinklersSigned-offDDS MECHANICAL FPS CORP06/01/2023
DOB NOWConstruction FenceSigned-offPENTA RESTORATION CORP05/30/2023
DOB NOWPlumbingSigned-offD.D.S. MECH PBG&HTG CORP05/25/2023
DOB NOWSupport of ExcavationSigned-offPENTA RESTORATION CORP05/22/2023
DOB NOWGeneral ConstructionPermit IssuedPENTA RESTORATION CORP05/22/2023
DOB NOWConstruction FenceSigned-offALBA SERVICES INC02/01/2023
DOB NOWSupported ScaffoldSigned-offTRI BOROUGH SCAFFOLDING01/19/2023
+ 1 more permits on file
1 project · most recent 08/17/2026
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
08/17/2026Permit IssuedPENTA RESTORATION CORPAir Conditioning Systems
Cooling
Lg ARUM096BTE5 8 tons · Vrf Outdoor ×26
ARUM121BTE5 10 tons · Vrf Outdoor ×6
ARUM144BTE5 12 tons · Vrf Outdoor ×3
ARUM96BTE5 8 tons · Vrf Outdoor ×1
ARUN038GSS4 4 tons · Vrf Outdoor ×3
ARUN072BTE5 6 tons · Vrf Outdoor ×1
LSU181HSV5 2 tons · Condensing Unit ×3
LSU243HLV3 2 tons · Condensing Unit ×3
ARUM072BTE5 6 tons · Vrf Outdoor ×2
Mitsubishi Electric PURY-P96TNU-A 8 tons · Vrf Outdoor ×9
PURY-P120TNU-A 10 tons · Vrf Outdoor ×2
PUMY-P96NKMU3 4 tons · Vrf Outdoor ×1
PURY-P144TNU-A 12 tons · Vrf Outdoor ×1
PURY-P72TNU-A 6 tons · Vrf Outdoor ×1
PUZ-A18NHA7 2 tons · Condensing Unit ×1
PUZ-A24NHA7 2 tons · Condensing Unit ×1
1 project · most recent 08/17/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
08/17/2026Signed-offD.D.S. MECH PBG&HTG CORPGas, Storm, Water/Sanitary
7 projects · most recent 08/08/2025
General Wiring
FiledStatusContractorScope
08/08/2025CompleteMAJOR ELECTRIC INC.General Wiring
03/27/2025CompleteGRID CITY ELECTRIC, CORP47 meters, 1 new_meters
05/09/2024CompleteTUXEDO ELEC'L CONTR'G INC—
04/17/2024CompleteMAJOR ELECTRIC INC.—
04/09/2024CompleteNASH ELECTRIC SERVICES IN—
11/27/2023CompleteNASH ELECTRIC SERVICES IN—
01/16/2023CompleteNASH ELECTRIC SERVICES IN—
1 project · most recent 08/17/2026
Steel Concrete Masonry
FiledStatusContractorScope
08/17/2026Permit IssuedPENTA RESTORATION CORPSteel, Concrete, Masonry
1 project · most recent 04/23/2024
Suspended Scaffold (SC)
FiledStatusContractorScope
04/23/2024——Suspended Scaffold (SC)
▾Field Inspections (DOB CAP) — 16
DateTypeResultReport
07/18/2025Pass-Final CND-Occupancy InspectionPassView ↗
06/09/2025Pass-Final CND-Occupancy InspectionPassView ↗
06/05/2025Pass-Final CND-Occupancy InspectionPassView ↗
03/12/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
03/12/2025Certified StandPipe-SD-Fixtures-Finish-SDCertifiedView ↗
03/10/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
02/25/2025Certified StandPipe-Fire Pump (SD)-Fire Pump TestCertifiedView ↗
02/21/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
02/21/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
02/20/2025Certified StandPipe-SD-Piping-Hydrostatic TestCertifiedView ↗
05/01/2024Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)CertifiedView ↗
01/18/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
01/18/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
12/22/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
12/08/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
10/19/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 149
DateRequirementInspectorRole
08/18/2026Fenestration air leakageJustin Mosesenergy_progress
08/18/2026VestibulesJustin Mosesenergy_progress
08/18/2026MasonrySAMI HAJJAR P.Especial
08/18/2026Wall Panels, Curtain Walls, and VeneersSAMI HAJJAR P.Especial
08/18/2026Exterior Insulation and Finish Systems (EIFS)SAMI HAJJAR P.Especial
08/18/2026Fire-Resistant Penetrations and JointsSAMI HAJJAR P.Especial
08/18/2026Fire-Resistance Rated ConstructionSAMI HAJJAR P.Eprogress
08/18/2026Energy Code Compliance InspectionsJustin Mosesprogress
08/18/2026Electrical motors and elevatorsJustin Mosesenergy_progress
08/18/2026Lighting controlsJustin Mosesenergy_progress
08/18/2026Insulation placement and R valuesJustin Mosesenergy_progress
08/18/2026Maintenance informationJustin Mosesenergy_progress
08/18/2026Air barrier - visual inspectionJustin Mosesenergy_progress
08/18/2026Protection of exposed foundation insulationJustin Mosesenergy_progress
08/18/2026Fenestration areasJustin Mosesenergy_progress
08/18/2026Lighting in dwelling unitsJustin Mosesenergy_progress
08/18/2026Interior lighting powerJustin Mosesenergy_progress
08/18/2026Air barrier continuity plan testingJustin Mosesenergy_progress
08/18/2026Exterior lighting powerJustin Mosesenergy_progress
08/18/2026MeteringJustin Mosesenergy_progress
08/18/2026Fenestration and door U-factor and product ratingsJustin Mosesenergy_progress
08/06/2026Electrical motors and elevatorsJustin Mosesenergy_progress
08/06/2026Lighting controlsJustin Mosesenergy_progress
08/06/2026Maintenance informationJustin Mosesenergy_progress
08/06/2026Fenestration areasJustin Mosesenergy_progress
Latest 25 of 149.
▾Documents — 234 on file (BIS + DOB NOW)
▸Plans & Drawings37
▸DOB NOWPlans/Sketch37
08/31/2026B00641108-P2Request digital key ↗
08/31/2026B00641108-I1Request digital key ↗
08/31/2026B00641108-P1Request digital key ↗
Showing 3 of 37 on file for this type
▸Applications & Permits5
▸BISPLAN / WORK APPROVAL APPLICATION2
01/18/2024340866030Open ↗
09/22/2022340866030Open ↗
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
01/31/2023340866030Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
01/31/2023340866030Open ↗
▸DOB NOWHPD - Permit Notice1
08/13/2026B00614012-I1Open ↗
▸Zoning, Tax Lot & Property Records13
▸DOB NOWZD1: DOB Zoning Diagram6
08/21/2026B00614012-A4Open ↗
08/19/2026B00614012-A6Open ↗
08/13/2026B00614012-A1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWZoning Exhibit form (1-5)6
08/21/2026B00614012-A4Open ↗
08/19/2026B00614012-A6Open ↗
08/13/2026B00614012-A3Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B00614012-I1Open ↗
▸Seals & Professional Certifications87
▸DOB NOWDPL-1: Design Professional Seal & Signature37
08/31/2026B00641108-I1Open ↗
08/31/2026B00641108-P1Open ↗
08/31/2026B00641108-P2Open ↗
Showing 3 of 37 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature27
09/02/2026B00614012-I1Open ↗
09/02/2026B00614012-I1Open ↗
09/01/2026B00614012-P7Open ↗
Showing 3 of 27 on file for this type
▸DOB NOWProgress Inspector Seal & Signature22
09/02/2026B00614012-I1Open ↗
09/02/2026B00614012-I1Open ↗
09/02/2026B00614012-I1Open ↗
Showing 3 of 22 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
09/22/2022340866030Open ↗
▸Trade Schedules & Equipment6
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)4
08/13/2026B00614012-I1Open ↗
08/13/2026B00614012-A3Open ↗
08/13/2026B00614012-P6Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWStandpipe Alarms Drawings2
08/15/2026B00614012-I1—
08/15/2026B00920948-I1—
▸Safety & Tenant Protection11
▸DOB NOWStreet Tree Checklist6
08/21/2026B00614012-A1Open ↗
08/21/2026B00614012-A4Open ↗
08/19/2026B00614012-A6Open ↗
Showing 3 of 6 on file for this type
▸BISBPP: STREET TREES SITE PLAN1
01/31/2023340866030Open ↗
▸BISSTREET TREE CHECKLIST1
01/31/2023340866030Open ↗
▸DOB NOWStreet Tree Sign Off1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWStreet Trees Site Plan1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026B00614012-I1Open ↗
▸Environmental & Asbestos28
▸DOB NOWOER: Notice to Proceed15
08/21/2026B00614012-A4Open ↗
08/19/2026B00614012-A6Open ↗
08/13/2026B00920948-I1Open ↗
Showing 3 of 15 on file for this type
▸DOB NOWOER: Notice of Satisfaction10
08/13/2026B00614012-S5Open ↗
08/13/2026B00614012-S2Open ↗
08/13/2026B00614012-S3Open ↗
Showing 3 of 10 on file for this type
▸BISENVIRONMENTAL RESTRICTIONS - OER NOTICE OF SATISFACTION1
09/04/2025340866030Open ↗
▸BISENVIRONMENTAL RESTRICTIONS - OER NOTICE TO PROCEED1
01/31/2023340866030Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026B00823118-I1Open ↗
▸Energy Compliance3
▸DOB NOWPreliminary Commissioning Report Certification2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026B00614012-I1Open ↗
▸Inspections & Test Reports7
▸DOB NOWConcrete Testing Exception Report2
08/13/2026B00614012-S3Open ↗
08/13/2026B00614012-S1Open ↗
▸DOB NOWTR5 Test Report2
08/13/2026B00614012-S1Open ↗
08/13/2026B00614012-S2Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWSOIL REPORT1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWTR4 Plot Diagram1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Approvals, Objections & Sign-offs2
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026B01132037-I1Open ↗
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter1
08/13/2026B01132037-I1Open ↗
▸Filing & Intake Forms3
▸BISADDITIONAL INFORMATION2
02/21/2025340866030Open ↗
02/22/2024340866030Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
09/22/2022340866030Open ↗
▸Other Documents32
▸DOB NOWSite Survey: Initial6
08/21/2026B00614012-A4Open ↗
08/19/2026B00614012-A6Open ↗
08/13/2026B00614012-P6Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone6
08/21/2026B00614012-A4Open ↗
08/19/2026B00614012-A6Open ↗
08/13/2026B00614012-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProperty Ownership Certification6
08/21/2026B00614012-A1Open ↗
08/21/2026B00614012-A4Open ↗
08/19/2026B00614012-A6Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWCalculations5
08/13/2026B01057367-I1Open ↗
08/13/2026B01057430-P1Open ↗
08/13/2026B01057430-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWManufacturer's Specifications5
08/13/2026B01057367-I1Open ↗
08/13/2026B01057430-P1Open ↗
08/13/2026B01057430-I1Open ↗
Showing 3 of 5 on file for this type
▸BISBPP: PHOTOS-SIGNED/SEALED BY APPLICANT1
01/31/2023340866030Open ↗
▸DOB NOWProject Specific General Liability (PGL1)1
08/13/2026B00614012-I1Open ↗
▸DOB NOWFinal Survey1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWAdjoining Owners Notification1
08/13/2026B00614012-S2Open ↗