← Back
BuildNYC
Miscellaneous one family
2611 AVENUE I
BROOKLYN · BIN 3206346
💬 Discuss this project
1915Year Built
2Stories
A9Building Class
R4Zoning
1,152 sfGross Floor Area
1Units
0 Active ViolationsFDNY Report ↗
Miscellaneous one family · Owner of record: Blue SKY Equities · 2,000 sf lot · 0.58 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofInterior alterations23p · 1 filing · 20 docs
Floor 2Interior alterations41p · 2 filings · 20 docs
Floor 1Interior alterations41p · 2 filings · 20 docs
CellarInterior alterations30p · 2 filings · 20 docs
Site & exteriorTemporary construction fence and sidewalk1p · 1 filing · 2 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Karo Properties2609/13/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/31/2024$455K—Private party → BLUE SKY EQUITIES 26, LLC$395/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Badaly Architects104/30/2026
Badaly Engineering1004/07/2026
Becall Engineering Services108/01/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Oet BuildersGeneral Contractor507/08/2026
Oet BuildersScaffold207/08/2026
L.L.G. Plumbing & HeatingPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Badaly Architect7137704/07/2026
Building Lifecycle
05/29/2026
Signed off — Alteration
PROVIDE NEW MECHANICAL SYSTEM
B01107382-I1
05/29/2026
Signed off — Alteration
PROVIDE NEW MECHANICAL SYSTEM
B01107382-S4
05/29/2026
Signed off — Alteration
CONSTRUCTION FENCE IN CONJUNCTION WITH ALTERATION APPLICATION #B01107382-I1
B01159654-I1
05/13/2026
Signed off — Alteration
INTERIOR RENOVATION OF EXISTING ONE FAMILY HOUSE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01066580-I1
05/12/2026
Closed: Unsafe buildings (DOB violation)
DOB violation · closed on the city's record
90 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FenceSigned-offOet Builders05/07/2026
DOB NOWGeneral ConstructionSigned-offOet Builders05/07/2026
DOB NOWStructuralSigned-offOet Builders05/06/2026
DOB NOWPlumbingSigned-offL.L.G. Plumbing & Heating05/08/2025
DOB NOWGeneral ConstructionSigned-offOet Builders04/29/2025
DOB NOWConstruction FenceSigned-offOet Builders02/20/2025
DOB NOWGeneral ConstructionSigned-offOet Builders01/16/2025
DOB NOWGeneral ConstructionSigned-offOet Builders07/17/2024
1 project · most recent 04/30/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScope
04/30/2026Signed-offOet BuildersHeating and Air Conditioning Systems, Ventilation Systems
1 project · most recent 04/30/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
04/30/2026Signed-offL.L.G. Plumbing & HeatingGas, Storm, Water/Sanitary
1 project · most recent 06/06/2025
General Wiring
FiledStatusContractorScope
06/06/2025CompleteJoseph Weinstein ElectricGeneral Wiring
1 project · most recent 04/30/2026
Masonry Wood
FiledStatusContractorScope
04/30/2026Signed-offOet BuildersMasonry, Wood
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
07/09/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/09/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
07/09/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
06/26/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/26/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 48
DateRequirementInspectorRole
04/24/2026FinalMOHAMMAD BADALYprogress
03/24/2026Insulation placement and R valuesSHAHIN BADALYenergy_progress
03/24/2026Interior lighting powerSHAHIN BADALYenergy_progress
03/24/2026Fenestration and door U-factor and product ratingsSHAHIN BADALYenergy_progress
03/24/2026Fenestration areasSHAHIN BADALYenergy_progress
03/24/2026Fenestration air leakageSHAHIN BADALYenergy_progress
03/24/2026Fire-Resistance Rated ConstructionSHAHIN BADALYprogress
03/24/2026FinalMOHAMMAD BADALYprogress
03/24/2026Energy Code Compliance InspectionsSHAHIN BADALYprogress
03/24/2026Structural Stability – Alterations of existing buildingsSHAHIN BADALYspecial
03/24/2026Fire-Resistant Penetrations and JointsSHAHIN BADALYspecial
03/24/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation—special
01/16/2026HVAC-R and service water piping design and insulationSHAHIN BADALYenergy_progress
01/16/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationSHAHIN BADALYspecial
01/16/2026Fire-Resistant Penetrations and JointsSHAHIN BADALYspecial
01/16/2026Energy Code Compliance InspectionsSHAHIN BADALYprogress
01/16/2026Maintenance informationSHAHIN BADALYenergy_progress
01/16/2026HVAC-R and service water heating system controlsSHAHIN BADALYenergy_progress
01/16/2026HVAC-R and service water heating equipmentSHAHIN BADALYenergy_progress
11/20/2025Fire-Resistant Penetrations and JointsSHAHIN BADALYspecial
11/20/2025Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationSHAHIN BADALYspecial
11/20/2025Energy Code Compliance InspectionsSHAHIN BADALYprogress
11/20/2025HVAC-R and service water piping design and insulationSHAHIN BADALYenergy_progress
11/20/2025Maintenance informationSHAHIN BADALYenergy_progress
11/20/2025HVAC-R and service water heating equipmentSHAHIN BADALYenergy_progress
Latest 25 of 48.
72 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account