DOB05/04/2023EMERGENCY WRK ORDR,EXPOSD/CORRODD CONCRETE SLAB REINFORCMT&GIRDERS, MISSNG CONCRTE ENCASMNT&CRACKNG ON SUBGRD LVL SLAB,UNDOCUMNTD SHORING, SEPARATION@CORNR EXP#1&EXP#2 WALLS. REMEDY: IMMEDIATLY SHORE/BRACE SLABS&WALLS UNDR NYS PE. WORK FILED W/I 2 DAYS, SUBMIT SIGNED/SEALED STRUCTRL RPT W. PHOTOS BY 5/12/2023
DOB05/04/2023EXPOSD&CORRODD CONC SLAB REINFRMT W.SPALLD CONC CVR BELOW GRADE LVL, BEAMS,GIRDERS EXPSD,MISSNG FIREPROFNG,SEVERE CRACKNG@EXP1,UNDOCMTD SHORNG@CELLAR,SEPARATN@CORNER OF EXP 1&2 WALLS RETAIN NYS RDP2 FILE PERMANENT REPAIR DRWGS BY 7/28/23 PERMANT RPR WRK BY PERMIT TO BEGIN BY 8/25/2023
DOB04/26/2023THE OCCUPIED PARKING STRUCTURE WITH CONCRETE/MASONRY FRAMING IS IN STATE OF DISREPAIR. OBSERVED CRACKS & EXPOSED STEEL REINFORCEMENT AT VARIOUS LOCATIONS OF CONCRETE COLUMNS/CEILINGS/BEAMS/SLABS AND/OR WALLS OF THE CELLAR LEVEL & 1ST FLOOR. LARGE STEP CRACKS ON EXP.1, 1ST FLOOR NEAR THE ROLLED DOWN GATE MOTOR.
DOB12/18/2013BLDG IS DEFECTIVE DUE TO CRACKED MASONRY WALL, PARTIALLY COLLAPSED 1ST FL CONCRETE SLAB, DELAMINATED CONCRETE SLAB @ BOTTOM/REINFORCEMENT THRUOUT, MISSING FIREPROOFING(ENCASING CONCRETE)@ STEEL BEAMS,LOOSE UN SECURED UTILITY PIPES THRUOUT & UNSTABLE STAIR FROM 1ST FL TO ROOF.LIC PE TO EVALUATE ENTIRE STRUCT/OBTAIN PERMITS/REPAIR/START BEFORE 1/6/14
ECB06/10/2009FAILURE TO MAINTAIN BLDG INTERIOR (HAZARDOUS). DEFECTS NOTED: PARTIAL COLLAPSE (APPROX 1 1/2 SQ FT) OF CONCRETE FLR ONTO BASMENT FROM 1ST FLR. EXPAND REBARS NOTED AT BASEMENT CEILING AT FEW SECTIONS. REMEDY:$-250 due
ECB02/13/2026FAILURE TO MAINTAIN BUILDING IN A CODE COMPLAINT MANNER. AT TIME OF INSPECTION OBSERVED A 1-STORY PARKING GARAGE WITH DEFECTS AT EXTERIOR. OBSERVED EXPOSED OPENING ABOVE ROLL DOWN GATE, MISSING LINTEL ABOVE WINHearing held — result not yet published
ECB10/24/2024FAILURE TO SUBMIT THE REQUIRED PARKING STRUCTURE INITIAL OBSERVATION REPORT FOR AN EXISTING PARKING STRUCTURE DOCUMENTING THE CONDITIONS OF PSID#X0003782 BY THE AUGUST 1,2024 DEADLINE.TO DATE,THE DEPARTMENT HASNothing owed — awaiting certificate of correction
ECB12/28/2023FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER IN DOB VIOLATION VIO23-01231, DATED 4/26/2023. RESPONDENT WAS REQUIRED TO SUBMIT AN ENGINEER'S REPORT CONCERNING STRUCTURALLY DEFICIENT CONDITIONS. AS OF 10/11/20Nothing owed — awaiting certificate of correction
ECB06/20/2023AS PER PARTIAL VACATE ORDER ISSUED ON MAY 5TH, 2023 AREAS WITHIN 100 FEET OF EXPOSURE#2 ON BOTH GRADE AND SUBGRADE LEVELS TO BE VACATED. OBSERVED UP TO FORTY SEDAN CARS PARKED WITHIN VACATE AREA AT GRADE AND SUNothing owed — awaiting certificate of correction
ECB06/20/2023AS PER THE DOB VIOLATION ISSUED ON MAY 4TH, 2023 "IMMEDIATELY SHORE/BRACE SLAB&WALLS UNDER NYS PROFESSIONAL ENGINEER. WORK FILED WITHIN TWO DAYS". OBSERVED TEMPORARY SHORING INSTALLED THROUGHOUT GRADE AND SUBGRNothing owed — awaiting certificate of correction
ECB05/10/2023OBSERVED AT THE 1-STORY PARKING STRUCTURE. AT CELLAR LEVEL RAMP SLAB HAS CRACKS & SPALLING CONCRETE, CEILING HAS SPALLING CONCRETE WITH EXPOSED REBAR AT VARIOUS LOCATIONS, EXIT DOOR OBSTRUCTED BY WHITE FORD VANNothing owed — awaiting certificate of correction
ECB12/11/2013FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTE: AT CELLAR LEVEL MULTIPLE CRACKS ON ALL LEVELS OF CEILING,WATER DAMAGE THROUGHOUT DELAMINATING CONCRETE,LOOSE AND DETACHED SEWER PIPES SUSPENDED FROMNothing owed — awaiting certificate of correction
ECB12/14/2011WORK W/O A PERMIT. EXPIRED PERMIT. NOTED : STRUCTURAL WORK UDER JOB # 220021535 IS 90 % COMPLETED JOB IS NOT SIGNED OFF AND PERMIT EXPIRED 11/01/10. REMEDY: RENEW PERMIT COMPLETE WORK AND WSIGN OFF APPLICATIONNothing owed — awaiting certificate of correction
ECB01/07/2010FAILURE TO MAINTAIN BLDG IN A CODE COMPLAINT MANNER. DEFECTS NOTED: @ CELLAR LEVEL SEVERAL STEL BEAMS & GIRDERS HAVE MISSING FIREPROOFING. - REPLACE MISSING FIREPROOFING @ ANY EXPOSED STRUCTURAL STEELNothing owed — awaiting certificate of correction
ECB01/07/2010FAILURE TO MAINTAIN BLDG EXTERIOR WALL IN A CODE COMPLAINT MANNER. DETETS NOTED: BRICKS & MORTAR MISSING @FRONT WALL @ SEALED LOWER LEVEL WINDOW, LINTEL MISSING & APPROX 6' OF SOLDIER COURSE MISSING - OBTAIN PENothing owed — awaiting certificate of correction
ECB01/07/2010FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY NOTED: EMERGENCY EXIT BLOCK WITH PARKED CARS. - REMOVE OBSTRUCTIONNothing owed — awaiting certificate of correction