← Back
Primarily 5-6 family with 1 store or office
266 STAGG STREET
BROOKLYN · BIN 3070888
💬 Discuss this project
1930Year Built
3Stories
S5Building Class
M1-1Zoning
4,125 sfGross Floor Area
6Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Primarily 5-6 family with 1 store or office · Owner of record: 266 STAGG PARTNERS LLC · 2,500 sf lot · 1.65 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalMechanicalPlumbing
Permit Issued — active, not yet Signed-off
Roof6p · 1 filing · 20 docs
Floor 34p · 2 filings · 20 docs
Floor 25p · 1 filing · 20 docs
Floor 1Under Construction11p · 1 filing · 18 docs
Cellar6p · 2 filings · 20 docs
1 job · most recent 07/11/2022
Gas Water/Sanitary
FiledStatusContractorScope
07/11/2022Signed-offWATSON'S PLBG, HTG, & BDGGas, Water/Sanitary
3 jobs · most recent 05/26/2026
General Wiring
FiledStatusContractorScope
05/26/2026Permit IssuedE & M ELECTRICAL NY CORPGeneral Wiring
01/26/2022Permit IssuedO.K. ELEC'L SERVICE CORPGeneral Wiring
11/12/2019CompleteACCURATE ELEC'L CORP.—
Building Lifecycle
All (96)Filed (11)Permit Issued (6)Signed Off (4)Violation (46)Inspection (7)Special Inspection (22)
02/19/2026
Signed off — Alteration
Installation, relocation and removal of plumbing fixtures as shown on plans filed herewith.
B01220442-I1
02/02/2026
Signed off — Alteration
Installation of mechanical units as shown on plans filed herewith.
B01211367-S1
02/02/2026
Signed off — Alteration
Installation of mechanical units as shown on plans filed herewith.
B01211367-I1
01/28/2026
Filed — Alteration
Installation of mechanical units as shown on plans filed herewith.
B01211367-P2
01/28/2026
Special inspection requirement — Lighting in dwelling units
Jeff Akerman
01/28/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jeff Akerman
01/28/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
VIJAY KUMAR
01/28/2026
Special inspection requirement — Energy Code Compliance Inspections
Jeff Akerman
01/28/2026
Special inspection requirement — Final
Feng Zhang
01/28/2026
Special inspection requirement — Fire-Resistance Rated Construction
Jeff Akerman
01/28/2026
Special inspection requirement — Insulation placement and R values
Jeff Akerman
11/17/2025
Permit issued — Mechanical Systems
B01211367-S1-MS
11/12/2025
Filed — Alteration
Installation of mechanical units as shown on plans filed herewith.
B01211367-S1
10/22/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
10/21/2025
Filed — Alteration
Installation of mechanical units as shown on plans filed herewith.
B01211367-P1
09/29/2025
Special inspection requirement — Maintenance information
Jeff Akerman
09/29/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
VIJAY KUMAR
09/29/2025
Special inspection requirement — Energy Code Compliance Inspections
Jeff Akerman
09/29/2025
Special inspection requirement — Final
Feng Zhang
09/29/2025
Special inspection requirement — Fire-Resistance Rated Construction
Jeff Akerman
09/29/2025
Special inspection requirement — Insulation placement and R values
Jeff Akerman
09/29/2025
Special inspection requirement — Lighting in dwelling units
Jeff Akerman
09/29/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jeff Akerman
09/29/2025
Special inspection requirement — Mechanical Systems
Jeff Akerman
09/29/2025
Special inspection requirement — Final
Feng Zhang
09/29/2025
Special inspection requirement — Energy Code Compliance Inspections
Jeff Akerman
09/29/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Jeff Akerman
09/29/2025
Special inspection requirement — HVAC-R and service water heating system controls
Jeff Akerman
09/29/2025
Special inspection requirement — HVAC-R and service water heating equipment
Jeff Akerman
07/16/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/13/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
06/11/2025
Violation issued (HPD, closed)
A
05/12/2025
Permit issued — Plumbing
B01220442-I1-PL
05/09/2025
Filed — Alteration
Installation, relocation and removal of plumbing fixtures as shown on plans filed herewith.
B01220442-I1
05/04/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jeff Akerman
04/18/2025
Permit issued — General Construction
B01211367-I1-GC
04/16/2025
Filed — Alteration
Installation of mechanical units as shown on plans filed herewith.
B01211367-I1
11/17/2023
Violation issued (HPD, closed)
I
03/27/2023
Violation issued (HPD, closed)
A
08/05/2022
Signed off — Alteration
GENERAL CONSTRUCTION TO RENOVATE APT 1R ON THE 1ST FLOOR. WORK WILL INCLUDE NEW PARTITIONS & FINISHES, AND NEW PLUMBING FIXTURES. NO CHANGE IN USE, EGRESS, OR OCCUPANCY UNDER THIS FILING.
B00635837-S1
07/13/2022
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
07/11/2022
Filed — Alteration
GENERAL CONSTRUCTION TO RENOVATE APT 1R ON THE 1ST FLOOR. WORK WILL INCLUDE NEW PARTITIONS & FINISHES, AND NEW PLUMBING FIXTURES. NO CHANGE IN USE, EGRESS, OR OCCUPANCY UNDER THIS FILING.
B00635837-P4
06/23/2022
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
04/27/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/13/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
04/13/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/08/2022
Permit issued — General Construction
B00635837-I1-GC
03/02/2022
Violation issued (HPD, closed)
A
02/16/2022
Filed — Alteration
GENERAL CONSTRUCTION TO RENOVATE APT 1R ON THE 1ST FLOOR. WORK WILL INCLUDE NEW PARTITIONS & FINISHES, AND NEW PLUMBING FIXTURES. NO CHANGE IN USE, EGRESS, OR OCCUPANCY UNDER THIS FILING.
B00635837-P3
02/03/2022
Filed — Alteration
GENERAL CONSTRUCTION TO RENOVATE APT 1R ON THE 1ST FLOOR. WORK WILL INCLUDE NEW PARTITIONS & FINISHES, AND NEW PLUMBING FIXTURES. NO CHANGE IN USE, EGRESS, OR OCCUPANCY UNDER THIS FILING.
B00635837-P1
02/03/2022
Filed — Alteration
GENERAL CONSTRUCTION TO RENOVATE APT 1R ON THE 1ST FLOOR. WORK WILL INCLUDE NEW PARTITIONS & FINISHES, AND NEW PLUMBING FIXTURES. NO CHANGE IN USE, EGRESS, OR OCCUPANCY UNDER THIS FILING.
B00635837-P2
01/27/2022
Violation issued (ECB, closed)
Construction
01/27/2022
Violation issued (ECB, closed)
Construction
01/27/2022
Violation issued (ECB, closed)
Construction
01/27/2022
Violation issued (ECB, closed)
Construction
01/20/2022
Violation issued (ECB, closed)
Construction
01/20/2022
Violation issued (ECB, closed)
Site Safety
01/14/2022
Permit issued — Plumbing
B00635837-S1-PL
01/13/2022
Permit issued — General Construction
B00635837-I1-GC
01/04/2022
Filed — Alteration
GENERAL CONSTRUCTION TO RENOVATE APT 1R ON THE 1ST FLOOR. WORK WILL INCLUDE NEW PARTITIONS & FINISHES, AND NEW PLUMBING FIXTURES. NO CHANGE IN USE, EGRESS, OR OCCUPANCY UNDER THIS FILING.
B00635837-S1
Latest 60 of 96 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
443 WILSON1807/08/2026
266 STAGG PARTNERS LLC303/22/2026
B07 CONSTRUCTION CORP403/22/2026
266 STAGG LLC103/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/21/2025$2.4M—266 STAGG PARTNERS LLC → 266 STAGG LLC$572/sf building
05/27/2021$1.6M—Private party → 266 STAGG PARTNERS LLC$376/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FOCAL POINT ARCHITECTS & ASS.501/28/2026
NS ENGINEERS, P.C.207/11/2022
ASHRAF CORP402/16/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
YOUBER DESIGN1203/21/2026
JACK JAFFA & ASSOCIATES1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BO7 CONSTRUCTION CORPGeneral Contractor407/08/2026
BEE CONSTRUCTIONS LLCGeneral Contractor204/09/2026
WATSON'S PLBG, HTG, & BDGPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AZ PROFESSIONAL ENGINEERI766301/28/2026
BIZ DESIGNS LLC6312501/28/2026
ASHRAF CORPORATION1973302/16/2022
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offBEE CONSTRUCTIONS LLC11/17/2025
DOB NOWPlumbingSigned-offWATSON'S PLBG, HTG, & BDG05/12/2025
DOB NOWGeneral ConstructionSigned-offBEE CONSTRUCTIONS LLC04/18/2025
DOB NOWGeneral ConstructionPermit IssuedBO7 CONSTRUCTION CORP04/08/2022
DOB NOWPlumbingSigned-offWATSON'S PLBG, HTG, & BDG01/14/2022
DOB NOWGeneral ConstructionPermit IssuedBO7 CONSTRUCTION CORP01/13/2022
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
10/22/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/16/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/13/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
07/13/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
06/23/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/13/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
04/13/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 22
DateRequirementInspectorRole
01/28/2026Lighting in dwelling unitsJeff Akermanenergy_progress
01/28/2026Fire-Resistant Penetrations and JointsJeff Akermanspecial
01/28/2026Structural Stability – Alterations of existing buildingsVIJAY KUMARspecial
01/28/2026Energy Code Compliance InspectionsJeff Akermanprogress
01/28/2026FinalFeng Zhangprogress
01/28/2026Fire-Resistance Rated ConstructionJeff Akermanprogress
01/28/2026Insulation placement and R valuesJeff Akermanenergy_progress
09/29/2025Maintenance informationJeff Akermanenergy_progress
09/29/2025Structural Stability – Alterations of existing buildingsVIJAY KUMARspecial
09/29/2025Energy Code Compliance InspectionsJeff Akermanprogress
09/29/2025FinalFeng Zhangprogress
09/29/2025Fire-Resistance Rated ConstructionJeff Akermanprogress
09/29/2025Insulation placement and R valuesJeff Akermanenergy_progress
09/29/2025Lighting in dwelling unitsJeff Akermanenergy_progress
09/29/2025Fire-Resistant Penetrations and JointsJeff Akermanspecial
09/29/2025Mechanical SystemsJeff Akermanspecial
09/29/2025FinalFeng Zhangprogress
09/29/2025Energy Code Compliance InspectionsJeff Akermanprogress
09/29/2025HVAC-R and service water piping design and insulationJeff Akermanenergy_progress
09/29/2025HVAC-R and service water heating system controlsJeff Akermanenergy_progress
09/29/2025HVAC-R and service water heating equipmentJeff Akermanenergy_progress
05/04/2025Fire-Resistant Penetrations and JointsJeff Akermanspecial
▾Documents — 50 on file (BIS + DOB NOW)
▸Plans & Drawings11
▸DOB NOWPlans/Sketch11
08/29/2026B00635837-I1Request digital key ↗
08/29/2026B00635837-S1Request digital key ↗
08/29/2026B00635837-P4Request digital key ↗
Showing 3 of 11 on file for this type
▸Seals & Professional Certifications28
▸DOB NOWDPL-1: Design Professional Seal & Signature11
08/29/2026B00635837-S1Open ↗
08/29/2026B00635837-I1Open ↗
08/29/2026B00635837-P3Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWProgress Inspector Seal & Signature11
09/23/2026B01211367-S1Open ↗
09/23/2026B01211367-S1Open ↗
09/23/2026B01211367-S1Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
09/23/2026B01211367-S1Open ↗
09/02/2026B01211367-P1Open ↗
09/02/2026B01211367-P1Open ↗
Showing 3 of 6 on file for this type
▸Environmental & Asbestos11
▸DOB NOWDEP ACP-5: Asbestos Assessment Report11
08/29/2026B00635837-S1Open ↗
08/29/2026B00635837-P4Open ↗
08/29/2026B00635837-I1Open ↗
Showing 3 of 11 on file for this type