← Back
City residence, one family
26A HUNTINGTON STREET
💬 Discuss this project
2022Year Built
3Stories
A4Building Class
R5Zoning
3,253 sfGross Floor Area
1Units
City residence, one family · 1,950 sf lot · 1.67 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Roof68p · 4 filings · 20 docs
Floor 361p · 1 filing · 20 docs
Floor 268p · 3 filings · 20 docs
Floor 161p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
RJ CAPITAL HOLDINGS2707/08/2026
SS DEV PARTNERS203/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/20/2024$3.5M—RJ RED HOOK HOMES LLC → Private party$1,090/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TAHIR DEMIRCIOGLU ARCHITECT PLLC303/27/2024
KARACOBAN ENGINEERING PC611/28/2023
WEXLER ASSOCIATES302/25/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BOYD CONSULTING2403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
RJ CAPITAL CONSTRUCTION LGeneral Contractor1907/08/2026
MORDECHAI LUNGERElectrical703/21/2026
EQUAL ELECTRICAL CONT INC 004850General Contractor703/22/2026
MEJ PLUMBING LLCPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
S&S CONCRETE & SOIL TESTI10081003/27/2024
Building Lifecycle
All (84)Filed (12)Permit Issued (13)Signed Off (6)Inspection (3)Objection (20)Special Inspection (30)
04/16/2024
Special inspection requirement — Lowest Floor Elevation
GLEN LANGER
04/16/2024
Special inspection requirement — Concrete - Cast-In-Place
GLEN LANGER
04/16/2024
Special inspection requirement — Fenestration areas
GLEN LANGER
04/16/2024
Special inspection requirement — Air barrier - visual inspection
GLEN LANGER
04/16/2024
Special inspection requirement — Lighting in dwelling units
GLEN LANGER
04/16/2024
Special inspection requirement — Energy Code Compliance Inspections
GLEN LANGER
04/16/2024
Special inspection requirement — Lighting controls
GLEN LANGER
04/16/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
GLEN LANGER
04/16/2024
Special inspection requirement — Protection of exposed foundation insulation
GLEN LANGER
04/16/2024
Special inspection requirement — Air barrier — testing
GLEN LANGER
04/16/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
GLEN LANGER
04/16/2024
Special inspection requirement — Fenestration air leakage
GLEN LANGER
04/16/2024
Special inspection requirement — Maintenance information
GLEN LANGER
04/16/2024
Special inspection requirement — Wall Panels, Curtain Walls, and Veneers
GLEN LANGER
04/16/2024
Special inspection requirement — Masonry
GLEN LANGER
04/16/2024
Special inspection requirement — Exterior lighting power
GLEN LANGER
04/16/2024
Special inspection requirement — Insulation placement and R values
GLEN LANGER
04/16/2024
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
GLEN LANGER
04/16/2024
Special inspection requirement — Permanent certificate
GLEN LANGER
04/16/2024
Special inspection requirement — Mastic and Intumescent Fire-resistant Coatings
GLEN LANGER
04/16/2024
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Michael St Pierre
04/16/2024
Special inspection requirement — Subgrade Inspections
GLEN LANGER
04/16/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
GLEN LANGER
04/16/2024
Special inspection requirement — Interior lighting power
GLEN LANGER
04/16/2024
Special inspection requirement — Fire-Resistance Rated Construction
GLEN LANGER
04/04/2024
Objection raised — Scope
04/04/2024
Objection resolved — Addressed
03/27/2024
Filed — New Building
Filing for (3) Story Residential New Building development with (1) dwelling unit - Building # 2. FILED IN CONJUNCTION WITH NB APPLICATION #B00522405
B00593363-P1
03/27/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
GLEN LANGER
03/27/2024
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
GLEN LANGER
03/27/2024
Special inspection requirement — Masonry
GLEN LANGER
03/27/2024
Special inspection requirement — Concrete - Cast-In-Place
GLEN LANGER
03/27/2024
Special inspection requirement — Mastic and Intumescent Fire-resistant Coatings
GLEN LANGER
01/22/2024
Signed off — Alteration
PLUMBING WORK FILED IN CONJUNCTION WITH NB APPLICATION #B00593363
B00601864-I1
11/29/2023
Signed off — Alteration
MECHANICAL JOB FILED IN CONJUNCTION WITH NB APPLICATION
B00602711-I1
11/28/2023
Filed — Alteration
PLUMBING WORK FILED IN CONJUNCTION WITH NB APPLICATION #B00593363
B00601864-P4
11/13/2023
Permit issued — Plumbing
B00601864-I1-PL
10/10/2023
Signed off — Alteration
CONSTURCTION FENCE FILED IN CONJUNCTION WITH NB JOB B00593363
B00650762-I1
09/28/2023
Filed — Alteration
PLUMBING WORK FILED IN CONJUNCTION WITH NB APPLICATION #B00593363
B00601864-P2
06/23/2023
Filed — Alteration
PLUMBING WORK FILED IN CONJUNCTION WITH NB APPLICATION #B00593363
B00601864-P1
06/23/2023
Filed — Alteration
MECHANICAL JOB FILED IN CONJUNCTION WITH NB APPLICATION
B00602711-P1
06/07/2023
Signed off — Alteration
EARTH WORK FILED IN CONJUNCTION WITH NEW BUILDING JOB B00593363
B00620881-S1
06/07/2023
Signed off — Alteration
EARTH WORK FILED IN CONJUNCTION WITH NEW BUILDING JOB B00593363
B00620881-I1
05/16/2023
Signed off — Alteration
STRUCTURAL WORK FILED IN CONJUNCTION WITH NEW BUILDING JOB B00
B00619619-I1
03/08/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
12/06/2022
Permit issued — Mechanical Systems
B00602711-I1-MS
11/29/2022
Permit issued — General Construction
B00593363-I1-GC
11/28/2022
Permit issued — Structural
B00619619-I1-ST
11/28/2022
Permit issued — Foundation
B00620881-I1-FO
11/28/2022
Permit issued — Earth Work
B00620881-S1-EA
11/28/2022
Permit issued — Construction Fence
B00650762-I1-FN
06/02/2022
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
06/02/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
04/28/2022
Permit issued — Plumbing
B00601864-I1-PL
03/28/2022
Permit issued — General Construction
B00593363-I1-GC
03/14/2022
Permit issued — Earth Work
B00620881-S1-EA
02/25/2022
Filed — Alteration
EARTH WORK FILED IN CONJUNCTION WITH NEW BUILDING JOB B00593363
B00620881-S1
01/27/2022
Permit issued — Foundation
B00620881-I1-FO
01/27/2022
Permit issued — Structural
B00619619-I1-ST
01/07/2022
Permit issued — Construction Fence
B00650762-I1-FN
Latest 60 of 84 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offKAY PLUMBING INC11/13/2023
DOB NOWMechanical SystemsSigned-offRJ CAPITAL CONSTRUCTION L12/06/2022
DOB NOWGeneral ConstructionPermit IssuedRJ CAPITAL CONSTRUCTION L11/29/2022
DOB NOWStructuralSigned-offRJ CAPITAL CONSTRUCTION L11/28/2022
DOB NOWFoundationSigned-offRJ CAPITAL CONSTRUCTION L11/28/2022
DOB NOWEarth WorkSigned-offRJ CAPITAL CONSTRUCTION L11/28/2022
DOB NOWConstruction FenceSigned-offRJ CAPITAL CONSTRUCTION L11/28/2022
DOB NOWPlumbingSigned-offKAY PLUMBING INC04/28/2022
DOB NOWGeneral ConstructionPermit IssuedRJ CAPITAL CONSTRUCTION L03/28/2022
DOB NOWEarth WorkSigned-offRJ CAPITAL CONSTRUCTION L03/14/2022
DOB NOWFoundationSigned-offRJ CAPITAL CONSTRUCTION L01/27/2022
DOB NOWStructuralSigned-offRJ CAPITAL CONSTRUCTION L01/27/2022
DOB NOWConstruction FenceSigned-offRJ CAPITAL CONSTRUCTION L01/07/2022
1 project · most recent 09/06/2024
General Wiring
FiledStatusContractorScope
09/06/2024CompleteEQUAL ELECTRICAL CONT INCGeneral Wiring
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
03/08/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
06/02/2022Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
06/02/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 92
DateRequirementInspectorRole
04/16/2024Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)GLEN LANGERspecial
04/16/2024Fenestration areasGLEN LANGERenergy_progress
04/16/2024Fenestration and door U-factor and product ratingsGLEN LANGERenergy_progress
04/16/2024Lighting in dwelling unitsGLEN LANGERenergy_progress
04/16/2024Maintenance informationGLEN LANGERenergy_progress
04/16/2024Fenestration air leakageGLEN LANGERenergy_progress
04/16/2024Lighting controlsGLEN LANGERenergy_progress
04/16/2024Air barrier - visual inspectionGLEN LANGERenergy_progress
04/16/2024Exterior lighting powerGLEN LANGERenergy_progress
04/16/2024HVAC-R and service water piping design and insulationGLEN LANGERenergy_progress
04/16/2024Interior lighting powerGLEN LANGERenergy_progress
04/16/2024Insulation placement and R valuesGLEN LANGERenergy_progress
04/16/2024Protection of exposed foundation insulationGLEN LANGERenergy_progress
04/16/2024Air barrier — testing GLEN LANGERenergy_progress
04/16/2024Permanent certificateGLEN LANGERenergy_progress
04/16/2024Fire-Resistance Rated ConstructionGLEN LANGERprogress
04/16/2024Energy Code Compliance InspectionsGLEN LANGERprogress
04/16/2024Lowest Floor ElevationGLEN LANGERprogress
04/16/2024Wall Panels, Curtain Walls, and VeneersGLEN LANGERspecial
04/16/2024Fire-Resistant Penetrations and JointsGLEN LANGERspecial
04/16/2024MasonryGLEN LANGERspecial
04/16/2024Mastic and Intumescent Fire-resistant CoatingsGLEN LANGERspecial
04/16/2024Subsurface Investigations (Borings/Test Pits)Michael St Pierrespecial
04/16/2024Subgrade InspectionsGLEN LANGERspecial
04/16/2024Concrete - Cast-In-PlaceGLEN LANGERspecial
Latest 25 of 92.
▾Documents — 90 on file (BIS + DOB NOW)
▸Plans & Drawings12
▸DOB NOWPlans/Sketch12
08/31/2026B00620881-S1Request digital key ↗
08/31/2026B00620881-I1Request digital key ↗
08/31/2026B00619619-I1Request digital key ↗
Showing 3 of 12 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION2
01/13/2023322051079Open ↗
12/09/2022322051079Open ↗
▸Zoning, Tax Lot & Property Records9
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026B00593363-I1Open ↗
08/13/2026B00593363-P1Open ↗
▸DOB NOWRestrictive Declaration/Easement 22
08/13/2026B00593363-I1Open ↗
08/13/2026B00593363-P1Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/13/2026B00593363-I1Open ↗
08/13/2026B00593363-P1Open ↗
▸DOB NOWRestrictive Declaration/Easement 12
08/13/2026B00593363-P1Open ↗
08/13/2026B00593363-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B00593363-I1Open ↗
▸Seals & Professional Certifications39
▸DOB NOWProgress Inspector Seal & Signature15
08/30/2026B00593363-I1Open ↗
08/30/2026B00593363-I1Open ↗
08/28/2026B00593363-P1Open ↗
Showing 3 of 15 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature12
08/31/2026B00620881-I1Open ↗
08/31/2026B00620881-S1Open ↗
08/31/2026B00619619-I1Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature12
08/30/2026B00593363-I1Open ↗
08/30/2026B00593363-I1Open ↗
08/30/2026B00593363-I1Open ↗
Showing 3 of 12 on file for this type
▸Trade Schedules & Equipment2
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/13/2026B00593363-P1Open ↗
08/13/2026B00593363-I1Open ↗
▸Safety & Tenant Protection5
▸DOB NOWStreet Tree Checklist2
08/25/2026B00593363-I1Open ↗
08/13/2026B00593363-P1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026B00593363-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026B00593363-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026B00593363-I1Open ↗
▸Energy Compliance3
▸DOB NOWEN2: As Built Energy Analysis.3
08/13/2026B00601864-I1Open ↗
08/13/2026B00593363-I1Open ↗
08/13/2026B00602711-I1Open ↗
▸Inspections & Test Reports4
▸DOB NOWSOIL REPORT2
08/13/2026B00593363-P1Open ↗
08/13/2026B00593363-I1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/13/2026B00593363-I1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026B00593363-I1Open ↗
▸Cost, Insurance & Ownership1
▸BISDEPT OF FINANCE VERIFICATION1
12/14/2022322051079Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
12/09/2022322051079Open ↗
▸Other Documents12
▸DOB NOWSite Survey: Initial2
08/13/2026B00593363-P1Open ↗
08/13/2026B00593363-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026B00593363-P1Open ↗
08/13/2026B00593363-I1Open ↗
▸DOB NOWProperty Ownership Certification2
08/25/2026B00593363-I1Open ↗
08/13/2026B00593363-P1Open ↗
▸BISPLOT DIAGRAM1
12/14/2022322051079Open ↗
▸DOB NOWLowest Floor Elevation Plan1
08/25/2026B00593363-I1Open ↗
▸DOB NOWFinal Survey1
08/13/2026B00593363-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026B00620881-S1Open ↗
▸DOB NOWProject Specific General Liability (PGL1)1
08/13/2026B00593363-I1Open ↗
▸DOB NOWFEMA Elevation Certificate (086-0-33)/Flood Proofing Certificate (086-0-34)1
08/13/2026B00593363-I1Open ↗