← Back
Elevator apt, semi-fireproof without stores
27-16 NEWTOWN AVENUE
QUEENS · Astoria (Central) · BIN 4006880
💬 Discuss this project
1940Year Built
4Stories
D1Building Class
R6AZoning
5,223 sfGross Floor Area
8Units
Rent Stabilized0 Open Violations
Elevator apt, semi-fireproof without stores · Owner of record: 2716 NEWTOWN LLC · 1,932 sf lot · 2.7 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionEquipmentGeneral
Roof16p · 4 filings · 20 docs
Bulkhead2p · 1 filing · 7 docs
Penthouse20p · 1 filing · 20 docs
Floor 435p · 4 filings · 20 docs
Floor 333p · 4 filings · 20 docs
Floor 234p · 4 filings · 20 docs
Floor 134p · 4 filings · 20 docs
Cellar6p · 1 filing · 20 docs
Site & exterior5p · 2 filings · 8 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
437 IRVING AVE807/08/2026
PHOENIX SUTTON STR INC703/22/2026
2716 NEWTOWN LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/06/2020$1.3M—Private party → 2716 NEWTOWN LLC$249/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
L & C ASSOCIATES1406/21/2022
ENTHINK ENGINEERS LLC201/06/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
L&C ASSOCIATES1403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
J S REMODELING NY INCGeneral Contractor1707/08/2026
PHOENIX SUTTON STR INCGeneral Contractor203/21/2026
JEM FIRE PREVENTION INCFire Protection107/08/2026
EH PLUMBING & HEATING CORPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
YAN ENGINEERING PLLC78511306/21/2022
Building Lifecycle
All (106)Filed (16)Permit Issued (10)Signed Off (7)Violation (9)Inspection (14)Objection (20)Special Inspection (30)
09/09/2024
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
08/26/2024
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
08/20/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/12/2024
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
08/07/2024
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
11/29/2023
Violation issued (HPD, closed)
I
03/04/2023
Signed off — ALT-CO - New Building with Existing Elements to Remain
CONVERT EXISTING TWO (2) DWELLING UNITS TO EIGHT (8) DWELLING UNITS. PROPOSED NEW HORIZONTAL ENLARGEMENT AT FRONT AND VERTICAL ENLARGEMENT ON EXISTING THREE (3)-STORY BUILDING TO FOUR (4)-STORY WITH PENTHOUSE. OBTAIN NEW CERTIFICATE OF OCCUPANCY
Q00514861-S2
12/08/2022
Signed off — ALT-CO - New Building with Existing Elements to Remain
CONVERT EXISTING TWO (2) DWELLING UNITS TO EIGHT (8) DWELLING UNITS. PROPOSED NEW HORIZONTAL ENLARGEMENT AT FRONT AND VERTICAL ENLARGEMENT ON EXISTING THREE (3)-STORY BUILDING TO FOUR (4)-STORY WITH PENTHOUSE. OBTAIN NEW CERTIFICATE OF OCCUPANCY
Q00514861-S1
09/06/2022
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/10/2022
Signed off — Alteration
PROVIDE PLUMBING SYSTEM THROUGHOUT THE FOUR-STORY BUILDING IN CONJUNCTION WITH JOB# Q00514861-I1
Q00519334-I1
06/27/2022
Signed off — Alteration
PROPOSED MECHANICAL SYSTEM FOR THE FOUR-STORY BUILDING IN CONJUNCTION WITH JOB# Q00514861-I1
Q00519365-I1
06/27/2022
Signed off — Alteration
INSTALL SPRINKLER SYSTEM THROUGHOUT THE FOUR-STORY BUILDING IN CONJUNCTION WITH JOB# Q00514861-I1
Q00519359-I1
06/21/2022
Filed — ALT-CO - New Building with Existing Elements to Remain
CONVERT EXISTING TWO (2) DWELLING UNITS TO EIGHT (8) DWELLING UNITS. PROPOSED NEW HORIZONTAL ENLARGEMENT AT FRONT AND VERTICAL ENLARGEMENT ON EXISTING THREE (3)-STORY BUILDING TO FOUR (4)-STORY WITH PENTHOUSE. OBTAIN NEW CERTIFICATE OF OCCUPANCY
Q00514861-P5
06/21/2022
Special inspection requirement — Lighting in dwelling units
SHI YAN
06/21/2022
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
SHI YAN
06/21/2022
Special inspection requirement — Protection of exposed foundation insulation
SHI YAN
06/21/2022
Special inspection requirement — Air barrier - visual inspection
SHI YAN
06/21/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
SHI YAN
06/21/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
SHI YAN
06/21/2022
Special inspection requirement — Fenestration air leakage
SHI YAN
06/21/2022
Special inspection requirement — Lighting controls
SHI YAN
06/21/2022
Special inspection requirement — Air barrier — testing
SHI YAN
06/21/2022
Special inspection requirement — Insulation placement and R values
SHI YAN
06/21/2022
Special inspection requirement — Metering
SHI YAN
06/21/2022
Special inspection requirement — Fire-Resistance Rated Construction
SHI YAN
06/21/2022
Special inspection requirement — Maintenance information
SHI YAN
06/21/2022
Special inspection requirement — Interior lighting power
SHI YAN
06/21/2022
Special inspection requirement — Air barrier continuity plan testing
SHI YAN
06/21/2022
Special inspection requirement — Fenestration areas
SHI YAN
06/21/2022
Special inspection requirement — Exterior lighting power
SHI YAN
06/21/2022
Special inspection requirement — Energy Code Compliance Inspections
SHI YAN
06/15/2022
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
06/14/2022
Filed — Alteration
PROPOSED MECHANICAL SYSTEM FOR THE FOUR-STORY BUILDING IN CONJUNCTION WITH JOB# Q00514861-I1
Q00519365-P1
06/14/2022
Special inspection requirement — Heating Systems
SHI YAN
06/14/2022
Special inspection requirement — Metering
SHI YAN
06/14/2022
Special inspection requirement — Fire-Resistance Rated Construction
SHI YAN
06/14/2022
Special inspection requirement — Mechanical Systems
SHI YAN
06/14/2022
Special inspection requirement — Duct leakage testing, insulation and design
SHI YAN
06/14/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
SHI YAN
06/14/2022
Special inspection requirement — Energy Code Compliance Inspections
SHI YAN
06/14/2022
Special inspection requirement — HVAC-R and service water heating system controls
SHI YAN
06/14/2022
Special inspection requirement — Maintenance information
SHI YAN
06/14/2022
Special inspection requirement — Final
SHI YAN
06/14/2022
Special inspection requirement — HVAC-R and service water heating equipment
SHI YAN
06/14/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
SHI YAN
06/13/2022
Signed off — Alteration
Q00519376-I1
06/13/2022
Filed — Alteration
INSTALL SPRINKLER SYSTEM THROUGHOUT THE FOUR-STORY BUILDING IN CONJUNCTION WITH JOB# Q00514861-I1
Q00519359-P1
06/09/2022
Permit issued — General Construction
Q00514861-I1-GC
06/09/2022
Permit issued — Construction Fence
Q00519376-I1-FN
06/09/2022
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
06/09/2022
Inspection — Certified Sprinkler - SP - Roughing
Certified
View inspection ↗
05/26/2022
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
05/23/2022
Objection resolved — Addressed
05/23/2022
Objection resolved — Addressed
05/23/2022
Objection resolved — Addressed
05/23/2022
Objection resolved — Addressed
05/23/2022
Objection resolved — Addressed
05/23/2022
Objection resolved — Addressed
05/23/2022
Objection resolved — Addressed
05/23/2022
Objection resolved — Addressed
Latest 60 of 106 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedJ S REMODELING NY INC06/09/2022
DOB NOWConstruction FenceSigned-offJ S REMODELING NY INC06/09/2022
DOB NOWSprinklersSigned-offJEM FIRE PREVENTION INC02/28/2022
DOB NOWSidewalk ShedSigned-offPHOENIX SUTTON STR INC09/01/2021
DOB NOWFoundationSigned-offJ S REMODELING NY INC08/17/2021
DOB NOWStructuralSigned-offJ S REMODELING NY INC08/03/2021
DOB NOWMechanical SystemsSigned-offJ S REMODELING NY INC08/03/2021
DOB NOWPlumbingSigned-offEH PLUMBING & HEATING COR07/15/2021
DOB NOWGeneral ConstructionPermit IssuedJ S REMODELING NY INC07/08/2021
DOB NOWConstruction FenceSigned-offJ S REMODELING NY INC07/06/2021
2 projects · most recent 06/13/2022
General Wiring
FiledStatusContractorScope
06/13/2022CompleteKJK ELECTRIC INCGeneral Wiring
08/25/2021CompleteELPO ELECTRICAL CONTG INC—
1 project · most recent 06/21/2022
FiledStatusContractorScope
06/21/2022Permit IssuedJ S REMODELING NY INC1 scope_items
▾Field Inspections (DOB CAP) — 14
DateTypeResultReport
09/09/2024Fail-Final CND-Occupancy InspectionFailView ↗
08/26/2024Fail-Final CND-Occupancy InspectionFailView ↗
08/20/2024Pass-Final CND-Occupancy InspectionPassView ↗
08/12/2024Fail-Final CND-Occupancy InspectionFailView ↗
08/07/2024Fail-Final CND-Occupancy InspectionFailView ↗
09/06/2022Pass-Final CND-Occupancy InspectionPassView ↗
06/15/2022Pass-Final CND-Occupancy InspectionPassView ↗
06/09/2022Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
06/09/2022Certified Sprinkler - SP - RoughingCertifiedView ↗
05/26/2022Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
03/21/2022Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
03/21/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/21/2022Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
01/21/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 94
DateRequirementInspectorRole
06/21/2022Protection of exposed foundation insulationSHI YANenergy_progress
06/21/2022Air barrier — testing SHI YANenergy_progress
06/21/2022Lighting controlsSHI YANenergy_progress
06/21/2022Maintenance informationSHI YANenergy_progress
06/21/2022MeteringSHI YANenergy_progress
06/21/2022Exterior lighting powerSHI YANenergy_progress
06/21/2022Air barrier continuity plan testingSHI YANenergy_progress
06/21/2022Interior lighting powerSHI YANenergy_progress
06/21/2022Fire-Resistant Penetrations and JointsSHI YANspecial
06/21/2022Fenestration air leakageSHI YANenergy_progress
06/21/2022Fenestration areasSHI YANenergy_progress
06/21/2022Fenestration and door U-factor and product ratingsSHI YANenergy_progress
06/21/2022Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationSHI YANspecial
06/21/2022Energy Code Compliance InspectionsSHI YANprogress
06/21/2022Fire-Resistance Rated ConstructionSHI YANprogress
06/21/2022Insulation placement and R valuesSHI YANenergy_progress
06/21/2022Air barrier - visual inspectionSHI YANenergy_progress
06/21/2022Lighting in dwelling unitsSHI YANenergy_progress
06/14/2022HVAC-R and service water piping design and insulationSHI YANenergy_progress
06/14/2022Fire-Resistant Penetrations and JointsSHI YANspecial
06/14/2022Mechanical SystemsSHI YANspecial
06/14/2022FinalSHI YANprogress
06/14/2022Energy Code Compliance InspectionsSHI YANprogress
06/14/2022Fire-Resistance Rated ConstructionSHI YANprogress
06/14/2022MeteringSHI YANenergy_progress
Latest 25 of 94.
▾Documents — 128 on file (BIS + DOB NOW)
▸Plans & Drawings16
▸DOB NOWPlans/Sketch16
08/27/2026Q00519376-I1Request digital key ↗
08/27/2026Q00519334-P1Request digital key ↗
08/27/2026Q00519334-I1Request digital key ↗
Showing 3 of 16 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
06/11/2021440678036Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
07/01/2021440678036Open ↗
▸Zoning, Tax Lot & Property Records9
▸DOB NOWZD1: DOB Zoning Diagram4
08/13/2026Q00514861-P5Open ↗
08/13/2026Q00514861-P1Open ↗
08/13/2026Q00514861-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWRestrictive Declaration/Easement 14
08/13/2026Q00514861-P5Open ↗
08/13/2026Q00514861-P1Open ↗
08/13/2026Q00514861-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q00514861-I1Open ↗
▸Seals & Professional Certifications57
▸DOB NOWProgress Inspector Seal & Signature21
09/02/2026Q00514861-P4Open ↗
09/02/2026Q00514861-P4Open ↗
09/02/2026Q00514861-P4Open ↗
Showing 3 of 21 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature18
09/02/2026Q00514861-P4Open ↗
09/02/2026Q00514861-P4Open ↗
09/01/2026Q00514861-S1Open ↗
Showing 3 of 18 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature16
08/27/2026Q00519376-I1Open ↗
08/27/2026Q00519334-I1Open ↗
08/27/2026Q00519334-P1Open ↗
Showing 3 of 16 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
06/11/2021440678036Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
06/11/2021440678036Open ↗
▸Trade Schedules & Equipment4
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)4
08/13/2026Q00514861-P1Open ↗
08/13/2026Q00514861-P5Open ↗
08/13/2026Q00514861-I1Open ↗
Showing 3 of 4 on file for this type
▸Safety & Tenant Protection4
▸BISSTREET TREE SIGNOFF1
07/01/2021440678036Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026Q00514861-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026Q00514861-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026Q00514861-I1Open ↗
▸Environmental & Asbestos12
▸DOB NOWDEP ACP-5: Asbestos Assessment Report10
08/27/2026Q00519334-I1Open ↗
08/27/2026Q00519334-P1Open ↗
08/27/2026Q00519359-I1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form2
08/26/2026Q00514861-S1Open ↗
08/26/2026Q00514861-S2Open ↗
▸Energy Compliance3
▸DOB NOWEN2: As Built Energy Analysis.3
08/13/2026Q00519334-I1Open ↗
08/13/2026Q00514861-I1Open ↗
08/13/2026Q00519365-I1Open ↗
▸Inspections & Test Reports3
▸DOB NOWTR4 Plot Diagram1
08/13/2026Q00514861-S1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q00514861-S1Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026Q00514861-S1Open ↗
▸Cost, Insurance & Ownership2
▸DOB NOWCertificate of Insurance1
08/13/2026Q00514861-I1Open ↗
▸DOB NOWCertification by Insurance Broker or Agency1
08/13/2026Q00514861-I1Open ↗
▸Filing & Intake Forms4
▸BISADDITIONAL INFORMATION2
07/01/2021440678036Open ↗
06/16/2021440678036Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
06/11/2021440678036Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
06/11/2021440678036Open ↗
▸Other Documents12
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone4
08/13/2026Q00514861-P5Open ↗
08/13/2026Q00514861-I1Open ↗
08/13/2026Q00514861-P1Open ↗
Showing 3 of 4 on file for this type
▸BISBPP: TOPOGRAPHIC SURVEY1
06/16/2021440678036Open ↗
▸BISBPP: PHOTOS-SIGNED/SEALED BY APPLICANT1
06/16/2021440678036Open ↗
▸BISRECORDS MGMT FEE PAYMENT RECEIPT1
06/16/2021440678036Open ↗
▸BISBPP - SUPPORTING DOCUMENTATION1
06/11/2021440678036Open ↗
▸DOB NOWAdditional Insured Authorizations1
08/13/2026Q00514861-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026Q00514861-P5Open ↗
▸DOB NOWFinal Survey1
08/13/2026Q00514861-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026Q00514861-S1Open ↗