← Back
Two family brick
27-22 14 STREET
QUEENS · Old Astoria-Hallets Point · BIN 4005611
💬 Discuss this project
1930Year Built
3Stories
B1Building Class
R5BZoning
1,836 sfGross Floor Area
2Units
Two family brick · 1,985 sf lot · 0.92 FAR built · Flood zone X
Locations of Work
Architecture
Roof2p · 1 filing · 9 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/05/2021$1.2M—— → —$673/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SQUARE ARCH, LLC211/18/2025
BENJAMIN HORST110/05/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
W J PROFESSIONAL EXPEDITING COMPANY203/21/2026
KAMTECH RESTORATION CORP403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
AA JEDSON COMPANY LLCGeneral Contractor207/08/2026
KAMTECH RESTORATION CORPGeneral Contractor203/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SQ. ARCH, LLC4802211/18/2025
RICHMOND TESTING LAB263110/05/2022
Building Lifecycle
All (17)Filed (3)Permit Issued (3)Signed Off (2)Special Inspection (9)
12/10/2025
Signed off — Alteration
ROOFTOP SOLAR INSTALLATION. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
Q01290495-I1
11/28/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Kaijin Liang
11/28/2025
Special inspection requirement — Energy Code Compliance Inspections
Kaijin Liang
11/28/2025
Special inspection requirement — Final
Kaijin Liang
11/28/2025
Special inspection requirement — Air barrier - visual inspection
Kaijin Liang
11/18/2025
Filed — Alteration
ROOFTOP SOLAR INSTALLATION. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
Q01290495-P1
10/15/2025
Permit issued — Solar
Q01290495-I1-SL
09/19/2025
Filed — Alteration
ROOFTOP SOLAR INSTALLATION. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
Q01290495-I1
02/27/2025
Signed off — Alteration
Q08014411-I1
05/09/2023
Permit issued — General Construction
Q08014411-I1-GC
11/02/2022
Permit issued — General Construction
Q08014411-I1-GC
10/05/2022
Filed — Alteration
Q08014411-I1
10/03/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
RICHARD LEMANSKY
10/03/2022
Special inspection requirement — Lighting controls
RICHARD LEMANSKY
10/03/2022
Special inspection requirement — Energy Code Compliance Inspections
RICHARD LEMANSKY
10/03/2022
Special inspection requirement — Final
RICHARD LEMANSKY
10/03/2022
Special inspection requirement — Lighting in dwelling units
RICHARD LEMANSKY
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offKAMTECH RESTORATION CORP10/15/2025
DOB NOWGeneral ConstructionSigned-offAA JEDSON COMPANY LLC05/09/2023
DOB NOWGeneral ConstructionSigned-offAA JEDSON COMPANY LLC11/02/2022
1 project · most recent 11/18/2025
FiledStatusContractorScope
11/18/2025CompleteBERGER QUALITY ELEC'L CON—
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
11/28/2025Fire-Resistant Penetrations and JointsKaijin Liangspecial
11/28/2025Energy Code Compliance InspectionsKaijin Liangprogress
11/28/2025FinalKaijin Liangprogress
11/28/2025Air barrier - visual inspectionKaijin Liangenergy_progress
10/03/2022Fire-Resistant Penetrations and JointsRICHARD LEMANSKYspecial
10/03/2022Lighting controlsRICHARD LEMANSKYenergy_progress
10/03/2022Energy Code Compliance InspectionsRICHARD LEMANSKYprogress
10/03/2022FinalRICHARD LEMANSKYprogress
10/03/2022Lighting in dwelling unitsRICHARD LEMANSKYenergy_progress
▾Documents — 15 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/25/2026Q08014411-I1Request digital key ↗
▸Seals & Professional Certifications10
▸DOB NOWProgress Inspector Seal & Signature5
08/27/2026Q01290495-I1Open ↗
08/27/2026Q01290495-I1Open ↗
08/27/2026Q01290495-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/25/2026Q08014411-I1Open ↗
08/13/2026Q01290495-P1Open ↗
08/13/2026Q01290495-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/27/2026Q01290495-I1Open ↗
08/23/2026Q08014411-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/25/2026Q08014411-I1Open ↗
08/13/2026Q01290495-I1Open ↗
08/13/2026Q01290495-P1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01290495-I1Open ↗