← Back
Two family converted from one family
27-25 GILLMORE STREET
QUEENS · BIN 4041394
💬 Discuss this project
1925Year Built
2.75Stories
B3Building Class
R3XZoning
1,840 sfGross Floor Area
2Units
Two family converted from one family · 2,700 sf lot · 0.68 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 29p · 1 filing · 16 docs
Floor 111p · 2 filings · 20 docs
Cellar10p · 2 filings · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/09/2020$675K—— → —$367/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LEE ENGINEERING, P.C.411/24/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
LEE ENGINEERING P C803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MARTE DEVELOPMENT LLCGeneral Contractor107/08/2026
TRU-FACERS CORPGeneral Contractor107/08/2026
C.R.U. MECHAN & HEAT INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
LEE ENGINEERING, P.C.2157411/24/2021
Building Lifecycle
All (23)Filed (4)Permit Issued (3)Signed Off (1)Inspection (2)Special Inspection (13)
12/03/2021
Signed off — Alteration
Q00469306-I1
11/24/2021
Filed — Alteration
Q00469306-P1
11/23/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
YEON LEE
11/23/2021
Special inspection requirement — Energy Code Compliance Inspections
YEON LEE
11/23/2021
Special inspection requirement — Final
YEON LEE
11/23/2021
Special inspection requirement — Fenestration air leakage
YEON LEE
11/23/2021
Special inspection requirement — Fenestration areas
YEON LEE
11/23/2021
Special inspection requirement — Maintenance information
YEON LEE
11/23/2021
Special inspection requirement — Fenestration and door U-factor and product ratings
YEON LEE
11/03/2021
Filed — Alteration
PLUMBING WORK OF INTERIOR RENOVATION IN 2 FAMILY HOUSE.
Q00470412-P1
10/25/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
YEON LEE
10/25/2021
Special inspection requirement — Energy Code Compliance Inspections
YEON LEE
10/25/2021
Special inspection requirement — HVAC-R and service water heating equipment
YEON LEE
10/25/2021
Special inspection requirement — HVAC-R and service water heating system controls
YEON LEE
10/25/2021
Special inspection requirement — Maintenance information
YEON LEE
10/25/2021
Special inspection requirement — HVAC-R and service water piping design and insulation
YEON LEE
07/06/2021
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
07/06/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/28/2021
Permit issued — Plumbing
Q00470412-I1-PL
06/22/2021
Permit issued — General Construction
Q00469306-I1-GC
04/19/2021
Permit issued — General Construction
Q00469306-I1-GC
03/02/2021
Filed — Alteration
PLUMBING WORK OF INTERIOR RENOVATION IN 2 FAMILY HOUSE.
Q00470412-I1
02/11/2021
Filed — Alteration
Q00469306-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedC.R.U. MECHAN & HEAT INC06/28/2021
DOB NOWGeneral ConstructionSigned-offMARTE DEVELOPMENT LLC06/22/2021
DOB NOWGeneral ConstructionSigned-offTRU-FACERS CORP04/19/2021
1 project · most recent 11/24/2021
General Wiring
FiledStatusContractorScope
11/24/2021CompleteWCK ELECTRIC CORP.General Wiring
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
07/06/2021Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/06/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
11/23/2021Fire-Resistant Penetrations and JointsYEON LEEspecial
11/23/2021Energy Code Compliance InspectionsYEON LEEprogress
11/23/2021FinalYEON LEEprogress
11/23/2021Fenestration air leakageYEON LEEenergy_progress
11/23/2021Fenestration areasYEON LEEenergy_progress
11/23/2021Maintenance informationYEON LEEenergy_progress
11/23/2021Fenestration and door U-factor and product ratingsYEON LEEenergy_progress
10/25/2021Fire-Resistant Penetrations and JointsYEON LEEspecial
10/25/2021Energy Code Compliance InspectionsYEON LEEprogress
10/25/2021HVAC-R and service water heating equipmentYEON LEEenergy_progress
10/25/2021HVAC-R and service water heating system controlsYEON LEEenergy_progress
10/25/2021Maintenance informationYEON LEEenergy_progress
10/25/2021HVAC-R and service water piping design and insulationYEON LEEenergy_progress
▾Documents — 30 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch - General Construction2
08/27/2026Q00469306-I1Request digital key ↗
08/27/2026Q00469306-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing2
08/27/2026Q00470412-I1Request digital key ↗
08/15/2026Q00470412-P1Request digital key ↗
▸DOB NOWPlans/Sketch2
08/27/2026Q00470412-P1Request digital key ↗
08/27/2026Q00470412-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWRestrictive Declaration/Easement 12
08/13/2026Q00470412-P1Open ↗
08/13/2026Q00470412-I1Open ↗
▸Seals & Professional Certifications17
▸DOB NOWProgress Inspector Seal & Signature11
09/02/2026Q00469306-P1Open ↗
09/02/2026Q00469306-P1Open ↗
09/02/2026Q00469306-P1Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/13/2026Q00470412-I1Open ↗
08/13/2026Q00469306-P1Open ↗
08/13/2026Q00469306-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
09/02/2026Q00469306-P1Open ↗
08/24/2026Q00470412-P1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/13/2026Q00470412-P1Open ↗
08/13/2026Q00469306-P1Open ↗
08/13/2026Q00469306-I1Open ↗
Showing 3 of 4 on file for this type
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026Q00469306-I1Open ↗