← Back
One story - permanent living quarter
27-52 GILLMORE STREET
QUEENS · BIN 4041350
💬 Discuss this project
1955Year Built
1Stories
A2Building Class
R3XZoning
1,050 sfGross Floor Area
1Units
One story - permanent living quarter · 4,000 sf lot · 0.26 FAR built · Flood zone X
Locations of Work
Architecture
Cellar1p · 1 filing · 10 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/17/2024$867K—Private party → Private party$826/sf building
06/25/2015$520K—— → —$495/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
COBBLE COURT ENGINEERING111/25/2024
ARCHITECTURE DESIGN, PLLC208/16/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
TK ARCDESIGN403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DECOSTA CONSTRUCTION INCGeneral Contractor303/21/2026
KLE CONSTRUCTION INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
COBBLE COURT ENGINEERING7825111/25/2024
WELLDONE INSPECTION INC.8628208/16/2024
Building Lifecycle
All (20)Filed (3)Permit Issued (2)Signed Off (2)Inspection (2)Objection (2)Special Inspection (9)
03/24/2025
Signed off — Alteration
PROPOSED INTERIOR RENOVATION FOR EXISTING SINGLE-FAMILY DETACHED BUILDING AS PER PLAN FILED HEREWITH. NO CHANGE OF USE, EGRESS OR CERTIFICATE OF OCCUPANCY.
Q01045353-I1
03/19/2025
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
02/24/2025
Signed off — Alteration
Q01147757-I1
12/03/2024
Permit issued — Solar
Q01147757-I1-SL
11/25/2024
Filed — Alteration
Q01147757-I1
11/25/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
DANIEL KAUFMAN
11/25/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
DANIEL KAUFMAN
11/25/2024
Special inspection requirement — Energy Code Compliance Inspections
DANIEL KAUFMAN
11/25/2024
Special inspection requirement — Final
DANIEL KAUFMAN
11/25/2024
Special inspection requirement — Air barrier - visual inspection
DANIEL KAUFMAN
09/10/2024
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
08/16/2024
Filed — Alteration
PROPOSED INTERIOR RENOVATION FOR EXISTING SINGLE-FAMILY DETACHED BUILDING AS PER PLAN FILED HEREWITH. NO CHANGE OF USE, EGRESS OR CERTIFICATE OF OCCUPANCY.
Q01045353-P2
07/31/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
QIUFAN JIANG
07/31/2024
Special inspection requirement — Energy Code Compliance Inspections
QIUFAN JIANG
07/31/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
QIUFAN JIANG
07/31/2024
Special inspection requirement — Fenestration areas
QIUFAN JIANG
06/11/2024
Permit issued — General Construction
Q01045353-I1-GC
05/31/2024
Objection resolved — Addressed
05/20/2024
Objection raised — Scope
05/10/2024
Filed — Alteration
PROPOSED INTERIOR RENOVATION FOR EXISTING SINGLE-FAMILY DETACHED BUILDING AS PER PLAN FILED HEREWITH. NO CHANGE OF USE, EGRESS OR CERTIFICATE OF OCCUPANCY.
Q01045353-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offDECOSTA CONSTRUCTION INC12/03/2024
DOB NOWGeneral ConstructionSigned-offKLE CONSTRUCTION INC06/11/2024
1 project · most recent 11/25/2024
FiledStatusContractorScope
11/25/2024CompleteLUNA NYC ELECTRIC CORP—
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
03/19/2025Pass-Final General Construction Non-Directive 14PassView ↗
09/10/2024Fail-Final General Construction Non-Directive 14FailView ↗
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
11/25/2024Fire-Resistant Penetrations and JointsDANIEL KAUFMANspecial
11/25/2024Structural Stability – Alterations of existing buildingsDANIEL KAUFMANspecial
11/25/2024Energy Code Compliance InspectionsDANIEL KAUFMANprogress
11/25/2024FinalDANIEL KAUFMANprogress
11/25/2024Air barrier - visual inspectionDANIEL KAUFMANenergy_progress
07/31/2024Fire-Resistant Penetrations and JointsQIUFAN JIANGspecial
07/31/2024Energy Code Compliance InspectionsQIUFAN JIANGprogress
07/31/2024Fenestration and door U-factor and product ratingsQIUFAN JIANGenergy_progress
07/31/2024Fenestration areasQIUFAN JIANGenergy_progress
▾Documents — 17 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/22/2026Q01045353-I1Request digital key ↗
08/22/2026Q01045353-P2Request digital key ↗
08/21/2026Q01147757-I1Request digital key ↗
▸Seals & Professional Certifications10
▸DOB NOWProgress Inspector Seal & Signature5
08/31/2026Q01045353-P2Open ↗
08/31/2026Q01045353-P2Open ↗
08/31/2026Q01045353-P2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/21/2026Q01147757-I1Open ↗
08/13/2026Q01045353-P2Open ↗
08/13/2026Q01045353-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/31/2026Q01045353-P2Open ↗
08/22/2026Q01147757-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/21/2026Q01147757-I1Open ↗
08/13/2026Q01045353-I1Open ↗
08/13/2026Q01045353-P2Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01147757-I1Open ↗