← Back
Two family brick
2703 YOUNG AVENUE
BRONX · Pelham Gardens · BIN 2054302
💬 Discuss this project
1950Year Built
2Stories
B1Building Class
R4Zoning
1,831 sfGross Floor Area
2Units
Two family brick · 1,800 sf lot · 1.02 FAR built · Flood zone X
Locations of Work
Electrical
Roof1 filing · 5 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MOMENTUM SOLAR112/11/2023
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JEFFREY MARINELLOElectrical103/21/2026
THOMPSON, NElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SHAHRISH SHUVO ENGINEERIN8524112/11/2023
Building Lifecycle
All (17)Filed (1)Permit Issued (1)Objection (10)Special Inspection (5)
01/11/2024
Permit issued — Solar
X00972418-I1-SL
01/04/2024
Objection resolved — Addressed
01/04/2024
Objection resolved — Addressed
01/04/2024
Objection resolved — Addressed
01/04/2024
Objection resolved — Addressed
01/04/2024
Objection resolved — Addressed
12/28/2023
Objection raised — Other
12/28/2023
Objection raised — Other
12/22/2023
Objection raised — Zoning
12/22/2023
Objection raised — Other
12/22/2023
Objection raised — Other
12/11/2023
Filed — Alteration
Description of Work: Installation of solar panels, rooftop, grid tied, RAILED (2.4KW)(6MODULES)
X00972418-I1
12/06/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Shahrish Shuvo
12/06/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
Shahrish Shuvo
12/06/2023
Special inspection requirement — Energy Code Compliance Inspections
Mina Makar
12/06/2023
Special inspection requirement — Final
Mina Makar
12/06/2023
Special inspection requirement — Air barrier - visual inspection
Mina Makar
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedMOMENTUM SOLAR01/11/2024
1 project · most recent 12/06/2023
FiledStatusContractorScope
12/06/2023CompleteISLAND ELECTRIC CORP—
1 project · most recent 12/11/2023
FiledStatusContractorScope
12/11/2023Permit IssuedMOMENTUM SOLAR6 panels, 2.4 kw, 106 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
12/06/2023Fire-Resistant Penetrations and JointsShahrish Shuvospecial
12/06/2023Structural Stability – Alterations of existing buildingsShahrish Shuvospecial
12/06/2023Energy Code Compliance InspectionsMina Makarprogress
12/06/2023FinalMina Makarprogress
12/06/2023Air barrier - visual inspectionMina Makarenergy_progress
▾Documents — 4 on file (BIS + DOB NOW)
▸Seals & Professional Certifications3
▸DOB NOWProgress Inspector Seal & Signature2
08/24/2026X00972418-I1Open ↗
08/24/2026X00972418-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/24/2026X00972418-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026X00972418-I1Open ↗