← Back
Three families
2717 MATTHEWS AVENUE
BRONX · Allerton · BIN 2053777
💬 Discuss this project
1960Year Built
2Stories
C0Building Class
R6Zoning
3,750 sfGross Floor Area
3Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Three families · Owner of record: 2717 MATTHEWS AVE LLC · 2,500 sf lot · 1.5 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingFire ProtectionGeneralOther
Floor 236p · 1 filing · 20 docs
Floor 136p · 1 filing · 20 docs
Basement40p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
2717 MATTHEWS AVE LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/04/2023$475K—Private party → 2717 MATTHEWS AVE LLC$127/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ADB ASSOCIATES709/25/2024
VASILIOS ARTEMIOU PE104/11/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NYC DESIGN FILE803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BUILDERS GROUP USA INCGeneral Contractor403/21/2026
PRIME PIPING & HEATING INFire Protection107/08/2026
PRIME PIPING & HEATING INPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF SERVICES CORP5616809/25/2024
Building Lifecycle
All (82)Filed (8)Permit Issued (4)Signed Off (3)Violation (5)Inspection (10)Objection (22)Special Inspection (30)
04/30/2026
Violation issued (HPD, closed)
A
06/05/2025
Violation issued (HPD, closed)
A
11/14/2024
Signed off — Alteration CO
Filing Sprinkler application subsequent to the primary approved application X00992509-I1
X00992509-S1
09/30/2024
Special inspection requirement — Energy Code Compliance Inspections
FAHAD FATEH
09/30/2024
Special inspection requirement — Fenestration air leakage
FAHAD FATEH
09/30/2024
Special inspection requirement — Permanent certificate
FAHAD FATEH
09/30/2024
Special inspection requirement — Maintenance information
FAHAD FATEH
09/30/2024
Special inspection requirement — Interior lighting power
FAHAD FATEH
09/30/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
FAHAD FATEH
09/30/2024
Special inspection requirement — Metering
FAHAD FATEH
09/30/2024
Special inspection requirement — Fenestration areas
FAHAD FATEH
09/30/2024
Special inspection requirement — Insulation placement and R values
FAHAD FATEH
09/30/2024
Special inspection requirement — Air barrier - visual inspection
FAHAD FATEH
09/30/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
09/30/2024
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
FAHAD FATEH
09/30/2024
Special inspection requirement — Fire-Resistance Rated Construction
FAHAD FATEH
09/27/2024
Signed off — Alteration CO
Filing Sprinkler application subsequent to the primary approved application X00992509-I1
X00992509-S2
09/25/2024
Filed — Alteration CO
Filing Sprinkler application subsequent to the primary approved application X00992509-I1
X00992509-P5
09/24/2024
Special inspection requirement — Insulation placement and R values
FAHAD FATEH
09/24/2024
Special inspection requirement — Fenestration air leakage
FAHAD FATEH
09/24/2024
Special inspection requirement — Interior lighting power
FAHAD FATEH
09/24/2024
Special inspection requirement — Metering
FAHAD FATEH
09/24/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
FAHAD FATEH
09/24/2024
Special inspection requirement — Maintenance information
FAHAD FATEH
09/24/2024
Special inspection requirement — Fenestration areas
FAHAD FATEH
09/24/2024
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
FAHAD FATEH
09/24/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
09/24/2024
Special inspection requirement — Energy Code Compliance Inspections
FAHAD FATEH
09/24/2024
Special inspection requirement — Fire-Resistance Rated Construction
FAHAD FATEH
09/24/2024
Special inspection requirement — Air barrier - visual inspection
FAHAD FATEH
09/24/2024
Special inspection requirement — Permanent certificate
FAHAD FATEH
09/17/2024
Signed off — Alteration CO
Filing Sprinkler application subsequent to the primary approved application X00992509-I1
X00992509-S3
09/11/2024
Filed — Alteration CO
Filing Sprinkler application subsequent to the primary approved application X00992509-I1
X00992509-P4
09/10/2024
Special inspection requirement — Ventilation and air distribution system
FAHAD FATEH
09/10/2024
Special inspection requirement — Heating Systems
FAHAD FATEH
09/10/2024
Special inspection requirement — Mechanical Systems
FAHAD FATEH
09/10/2024
Special inspection requirement — Post-installed Anchors
FAHAD FATEH
09/05/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/28/2024
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
08/26/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
08/23/2024
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
08/23/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/08/2024
Filed — Alteration CO
Filing Sprinkler application subsequent to the primary approved application X00992509-I1
X00992509-P3
08/06/2024
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
08/05/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/24/2024
Filed — Alteration CO
Filing Sprinkler application subsequent to the primary approved application X00992509-I1
X00992509-P2
07/18/2024
Violation issued (ECB, closed)
Construction
07/18/2024
Violation issued (ECB, closed)
Construction
07/18/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/03/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
06/27/2024
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
06/05/2024
Permit issued — Mechanical Systems
X00992509-S1-MS
06/04/2024
Permit issued — General Construction
X00992509-I1-GC
05/30/2024
Permit issued — Plumbing
X00992509-S2-PL
05/30/2024
Permit issued — Sprinklers
X00992509-S3-EW-SP
04/19/2024
Objection resolved — Addressed
04/19/2024
Objection resolved — Addressed
04/19/2024
Objection resolved — Addressed
04/18/2024
Objection raised — Cost
04/18/2024
Objection raised — Admin
Latest 60 of 82 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offBUILDERS GROUP USA06/05/2024
DOB NOWGeneral ConstructionPermit IssuedBUILDERS GROUP USA06/04/2024
DOB NOWPlumbingSigned-offPRIME PIPING & HEATING IN05/30/2024
DOB NOWSprinklersSigned-offA M B MECHANICAL INC05/30/2024
1 project · most recent 09/25/2024
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
09/25/2024Signed-offBUILDERS GROUP USA INCHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Daikin 2MXS18NMVJUA 110,000 BTU · Heat Pump Outdoor ×6
3MXS24WMVJU9 144,000 BTU · Heat Pump Outdoor ×6
RXS12LVJU 52,800 BTU · Heat Pump Outdoor ×4
Ventilation
Nutone AEN110 110 CFM · Exhaust Fan ×16
QTXEN150 150 CFM · Kitchen Exhaust ×16
1 project · most recent 09/25/2024
Sprinkler System
FiledStatusContractorScope
09/25/2024Signed-offPRIME PIPING & HEATING INSprinkler System
1 project · most recent 09/25/2024
Water/Sanitary
FiledStatusContractorScope
09/25/2024Signed-offA M B MECHANICAL INCWater/Sanitary
1 project · most recent 03/25/2024
General Wiring
FiledStatusContractorScope
03/25/2024CompleteFRIED ELECTRIC CO.General Wiring
▾Field Inspections (DOB CAP) — 10
DateTypeResultReport
09/05/2024Pass-Final CND-Occupancy InspectionPassView ↗
08/28/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
08/26/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
08/23/2024Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
08/23/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/06/2024Pass-Final PL - UndergroundPassView ↗
08/05/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/18/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/03/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/27/2024Pass-Final PL - UndergroundPassView ↗
▾Special Inspection Requirements (DOB NOW) — 48
DateRequirementInspectorRole
09/30/2024Energy Code Compliance InspectionsFAHAD FATEHprogress
09/30/2024Fenestration air leakageFAHAD FATEHenergy_progress
09/30/2024Permanent certificateFAHAD FATEHenergy_progress
09/30/2024Maintenance informationFAHAD FATEHenergy_progress
09/30/2024Interior lighting powerFAHAD FATEHenergy_progress
09/30/2024Fenestration and door U-factor and product ratingsFAHAD FATEHenergy_progress
09/30/2024MeteringFAHAD FATEHenergy_progress
09/30/2024Fenestration areasFAHAD FATEHenergy_progress
09/30/2024Insulation placement and R valuesFAHAD FATEHenergy_progress
09/30/2024Air barrier - visual inspectionFAHAD FATEHenergy_progress
09/30/2024Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
09/30/2024Exterior Insulation and Finish Systems (EIFS)FAHAD FATEHspecial
09/30/2024Fire-Resistance Rated ConstructionFAHAD FATEHprogress
09/24/2024Insulation placement and R valuesFAHAD FATEHenergy_progress
09/24/2024Fenestration air leakageFAHAD FATEHenergy_progress
09/24/2024Interior lighting powerFAHAD FATEHenergy_progress
09/24/2024MeteringFAHAD FATEHenergy_progress
09/24/2024Fenestration and door U-factor and product ratingsFAHAD FATEHenergy_progress
09/24/2024Maintenance informationFAHAD FATEHenergy_progress
09/24/2024Fenestration areasFAHAD FATEHenergy_progress
09/24/2024Exterior Insulation and Finish Systems (EIFS)FAHAD FATEHspecial
09/24/2024Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
09/24/2024Energy Code Compliance InspectionsFAHAD FATEHprogress
09/24/2024Fire-Resistance Rated ConstructionFAHAD FATEHprogress
09/24/2024Air barrier - visual inspectionFAHAD FATEHenergy_progress
Latest 25 of 48.
▾Documents — 43 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
08/21/2026X00992509-P3Request digital key ↗
08/21/2026X00992509-P2Request digital key ↗
08/21/2026X00992509-S3Request digital key ↗
Showing 3 of 8 on file for this type
▸Seals & Professional Certifications23
▸DOB NOWProgress Inspector Seal & Signature8
09/29/2026X00992509-P5Open ↗
09/29/2026X00992509-P5Open ↗
09/01/2026X00992509-S2Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/21/2026X00992509-P3Open ↗
08/21/2026X00992509-P2Open ↗
08/21/2026X00992509-S3Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
09/29/2026X00992509-P5Open ↗
09/29/2026X00992509-P5Open ↗
09/01/2026X00992509-S2Open ↗
Showing 3 of 7 on file for this type
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report8
08/21/2026X00992509-P3Open ↗
08/21/2026X00992509-P2Open ↗
08/21/2026X00992509-S3Open ↗
Showing 3 of 8 on file for this type
▸Other Documents4
▸DOB NOWProperty Ownership Certification3
08/21/2026X00992509-P3Open ↗
08/21/2026X00992509-I1Open ↗
08/21/2026X00992509-P5Open ↗
▸DOB NOWFinal Survey1
08/13/2026X00992509-I1Open ↗