← Back
Two family brick
272 NICHOLS AVENUE
BROOKLYN · Cypress Hills · BIN 3092973
💬 Discuss this project
1910Year Built
2Stories
B1Building Class
R5Zoning
2,128 sfGross Floor Area
2Units
16 Open Violations ▸FDNY Report ↗
Two family brick · 1,750 sf lot · 1.22 FAR built · Flood zone X
Locations of Work
ArchitectureElectrical
Roof2p · 1 filing · 7 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC107/04/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SUNCO CAPITAL203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SUNCO CAPITAL LLCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854107/04/2024
Building Lifecycle
All (38)Filed (1)Permit Issued (1)Signed Off (1)Violation (30)Special Inspection (5)
07/07/2025
Violation issued (HPD, open)
I
07/02/2025
Violation issued (HPD, closed)
B
07/02/2025
Violation issued (HPD, closed)
B
07/02/2025
Violation issued (HPD, closed)
C
07/02/2025
Violation issued (HPD, open)
C
03/31/2025
Violation issued (HPD, open)
B
03/31/2025
Violation issued (HPD, open)
B
03/31/2025
Violation issued (HPD, open)
B
12/20/2024
Signed off — Alteration
INSTALLATION OF SOLAR PANELS ON ROOF. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B01053712-I1
07/29/2024
Permit issued — Solar
B01053712-I1-SL
07/04/2024
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON ROOF. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B01053712-I1
05/20/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
05/20/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
05/20/2024
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
05/20/2024
Special inspection requirement — Final
TOM PETERSEN
05/20/2024
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
06/26/2018
Violation issued (ECB, closed)
Construction
03/26/2018
Violation issued (ECB, closed)
Construction
02/10/2018
Violation issued (ECB, closed)
Construction
12/22/2017
Violation issued (ECB, closed)
Construction
11/18/2017
Violation issued (ECB, closed)
Construction
11/15/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/03/2017
Violation issued (ECB, closed)
Construction
08/28/2017
Violation issued (ECB, closed)
Construction
08/22/2017
Violation issued (ECB, closed)
Construction
05/28/2010
Violation issued (HPD, open)
B
05/28/2010
Violation issued (HPD, open)
C
04/19/2010
Violation issued (HPD, open)
C
02/16/2010
Violation issued (HPD, open)
C
02/16/2010
Violation issued (HPD, open)
C
02/11/2010
Violation issued (HPD, open)
C
02/11/2010
Violation issued (HPD, open)
B
03/30/2006
Violation issued (HPD, open)
B
03/30/2006
Violation issued (HPD, open)
B
03/30/2006
Violation issued (HPD, open)
B
03/30/2006
Violation issued (HPD, open)
B
04/01/2005
Violation issued (ECB, closed)
Quality of Life
04/01/2005
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offSUNCO CAPITAL LLC07/29/2024
BISPLISSUEDROCK E SMALL PLBG&HTG INC06/29/2012
BISOTISSUEDSSM DEVELOPMENT CORP06/20/2012
1 project · most recent 09/23/2024
FiledStatusContractorScope
09/23/2024CompleteBERGER QUALITY ELEC'L CON—
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
05/20/2024Fire-Resistant Penetrations and JointsTOM PETERSENspecial
05/20/2024Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
05/20/2024Energy Code Compliance InspectionsTOM PETERSENprogress
05/20/2024FinalTOM PETERSENprogress
05/20/2024Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 27 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/24/2026B01053712-I1Request digital key ↗
▸Applications & Permits3
▸BISWORK PERMIT APPLICATION2
07/02/2012320493060Open ↗
06/22/2012320493060Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
06/25/2012320493060Open ↗
▸Seals & Professional Certifications6
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
11/09/2012320493060Open ↗
06/25/2012320493060Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026B01053712-I1Open ↗
09/01/2026B01053712-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026B01053712-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/01/2026B01053712-I1Open ↗
▸Trade Schedules & Equipment4
▸BISSELF-CERT PLUMBING NOTICE3
10/11/2012320493060Open ↗
10/01/2012320493060Open ↗
09/28/2012320493060Open ↗
▸BISSCHEDULE B - PLUMBING1
06/25/2012320493060Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
06/25/2012320493060Open ↗
▸Environmental & Asbestos3
▸BISTHIS IS NOT AN ASBESTOS PROJECT1
06/25/2012320493060Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
06/25/2012320493060Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026B01053712-I1Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
11/09/2012320493060Open ↗
06/25/2012320493060Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
11/09/2012320493060Open ↗
▸Approvals, Objections & Sign-offs3
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
11/09/2012320493060Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
06/25/2012320493060Open ↗
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026B01053712-I1Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
11/09/2012320493060Open ↗
06/25/2012320493060Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
06/25/2012320493060Open ↗