← Back
One story retail building
2720 CHURCH AVENUE
BROOKLYN · East Flatbush-Erasmus · BIN 3429434
💬 Discuss this project
1931Year Built
1Stories
K1Building Class
R6Zoning
6,000 sfGross Floor Area
1Units
3 Open Violations 0 unresolved · 3 paperwork only ▸FDNY Report ↗
One story retail building · Owner of record: WFS BROTHERS REALTY LLC · 14,865 sf lot · 0.4 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionLandscapeCivilGeneral
Permit Issued — active, not yet Signed-off
CellarUnder Construction55p · 1 filing · 20 docs
Site & exteriorUnder Construction294p · 1 filing · 20 docs
Filed — no permit issued3p · 2 filings · 6 docs
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BOYD CONSULTING2403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DYNAMIC DEVELOPMENT AND CGeneral Contractor307/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SJS INSPECTIONS AND CONSU8286802/06/2024
Building Lifecycle
All (126)Filed (14)Permit Issued (3)Violation (3)Objection (76)Special Inspection (30)
07/23/2026
Filed — Alteration
ENGINEERED ENCLOSURE IN CONJUNCTION WITH NEW BUILDING JOB# B00789072. NO CHNAGE IN USE, EGRESS OR OCCUPANCY.
B01435386-I1
06/26/2026
Violation issued (ECB, open)
Unknown
06/26/2026
Violation issued (ECB, open)
Construction
06/26/2026
Violation issued (ECB, open)
Construction
05/28/2026
Permit issued — Support of Excavation
B00789072-S7-SE
05/28/2026
Permit issued — Foundation
B00789072-S5-FO
05/20/2026
Permit issued — Construction Fence
B00789072-S9-FN
05/15/2026
Filed — New Building
Engineered enclosure system to provide roof and overhead protection for adjacent property
B00789072-S9
01/20/2026
Objection resolved — Addressed
11/21/2025
Objection raised — Other
10/29/2025
Filed — New Building
Engineered enclosure system to provide roof and overhead protection for adjacent property
B00789072-P3
06/17/2025
Objection raised — Other
06/02/2025
Objection resolved — Resolved
04/22/2025
Objection raised — Other
04/14/2025
Filed — New Building
Engineered enclosure system to provide roof and overhead protection for adjacent property
B00789072-P2
02/19/2025
Filed — New Building
Engineered enclosure system to provide roof and overhead protection for adjacent property
B00789072-P1
02/18/2025
Special inspection requirement — Insulation placement and R values
02/18/2025
Special inspection requirement — Lighting in dwelling units
02/18/2025
Special inspection requirement — Lighting controls
02/18/2025
Special inspection requirement — Air barrier - visual inspection
02/18/2025
Special inspection requirement — Protection of exposed foundation insulation
02/18/2025
Special inspection requirement — Concrete - Cast-In-Place
02/18/2025
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
02/18/2025
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
02/18/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
02/18/2025
Special inspection requirement — Luminous Exit Path Markings
02/18/2025
Special inspection requirement — Masonry
02/18/2025
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
02/18/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
02/18/2025
Special inspection requirement — Subgrade Inspections
02/18/2025
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
02/18/2025
Special inspection requirement — Energy Code Compliance Inspections
02/18/2025
Special inspection requirement — Fire-Resistance Rated Construction
02/18/2025
Special inspection requirement — Metering
02/18/2025
Special inspection requirement — Fenestration air leakage
02/18/2025
Special inspection requirement — Electrical motors and elevators
02/18/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
02/18/2025
Special inspection requirement — Interior lighting power
02/18/2025
Special inspection requirement — Fenestration areas
02/18/2025
Special inspection requirement — Exterior lighting power
02/18/2025
Special inspection requirement — Maintenance information
02/18/2025
Special inspection requirement — Air barrier — testing
03/27/2024
Objection resolved — Addressed
03/27/2024
Objection resolved — Addressed
03/13/2024
Objection resolved — Addressed
03/06/2024
Objection resolved — Addressed
02/26/2024
Objection resolved — Addressed
02/23/2024
Objection resolved — Addressed
02/21/2024
Objection resolved — Addressed
02/09/2024
Objection raised — Other
02/07/2024
Objection resolved — Addressed
02/06/2024
Filed — New Building
Engineered enclosure system to provide roof and overhead protection for adjacent property
B00789072-S7
01/22/2024
Objection resolved — Addressed
01/22/2024
Objection resolved — Addressed
12/29/2023
Objection raised — Other
12/29/2023
Objection raised — Other
12/29/2023
Objection raised — Other
12/29/2023
Objection raised — Other
12/29/2023
Objection raised — Other
12/29/2023
Objection resolved — Addressed
Latest 60 of 126 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSupport of ExcavationPermit IssuedDYNAMIC DEVELOPMENT AND C05/28/2026
DOB NOWFoundationPermit IssuedDYNAMIC DEVELOPMENT AND C05/28/2026
DOB NOWConstruction FencePermit IssuedDYNAMIC DEVELOPMENT AND C05/20/2026
1 project · most recent 05/15/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
05/15/2026Permit IssuedDYNAMIC DEVELOPMENT AND CHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Lg ARUM096BTE5 8 tons · Vrf Outdoor ×9
LSU180HSV5 1 tons · Vrf Outdoor ×2
ARUM144BTE5 12 tons · Vrf Outdoor ×1
ARUN048GSS4 4 tons · Vrf Outdoor ×1
— ARUM096BTE5 8 tons · Vrf Outdoor ×1
1 project · most recent 05/15/2026
Sprinkler System
FiledStatusContractorScope
05/15/2026——Sprinkler System
1 project · most recent 05/15/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
05/15/2026——Gas, Storm, Water/Sanitary
1 project · most recent 05/15/2026
Concrete
FiledStatusContractorScope
05/15/2026Permit IssuedDYNAMIC DEVELOPMENT AND CConcrete
1 project · most recent 05/15/2026
Fence
FiledStatusContractorScope
05/15/2026Permit IssuedDYNAMIC DEVELOPMENT AND CFence
▾Special Inspection Requirements (DOB NOW) — 34
DateRequirementInspectorRole
02/18/2025Insulation placement and R values—energy_progress
02/18/2025Lighting in dwelling units—energy_progress
02/18/2025Lighting controls—energy_progress
02/18/2025Air barrier - visual inspection—energy_progress
02/18/2025Protection of exposed foundation insulation—energy_progress
02/18/2025Concrete - Cast-In-Place—special
02/18/2025Excavations - Sheeting, Shoring, and Bracing—special
02/18/2025Exterior Insulation and Finish Systems (EIFS)—special
02/18/2025Fire-Resistant Penetrations and Joints—special
02/18/2025Luminous Exit Path Markings—special
02/18/2025Masonry—special
02/18/2025Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation—special
02/18/2025Structural Stability – Alterations of existing buildings—special
02/18/2025Subgrade Inspections—special
02/18/2025Subsurface Investigations (Borings/Test Pits)—special
02/18/2025Energy Code Compliance Inspections—progress
02/18/2025Fire-Resistance Rated Construction—progress
02/18/2025Metering—energy_progress
02/18/2025Fenestration air leakage—energy_progress
02/18/2025Electrical motors and elevators—energy_progress
02/18/2025Fenestration and door U-factor and product ratings—energy_progress
02/18/2025Interior lighting power—energy_progress
02/18/2025Fenestration areas—energy_progress
02/18/2025Exterior lighting power—energy_progress
02/18/2025Maintenance information—energy_progress
Latest 25 of 34.
▾Documents — 78 on file (BIS + DOB NOW)
▸Plans & Drawings15
▸DOB NOWPlans/Sketch15
08/28/2026B00789072-S9Request digital key ↗
08/28/2026B00789072-P1Request digital key ↗
08/27/2026B00855524-I1Request digital key ↗
Showing 3 of 15 on file for this type
▸Applications & Permits2
▸BISBPP-5 - Authorization to the Department of Transportation1
04/18/2023340883672Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
03/28/2023340883672Open ↗
▸Zoning, Tax Lot & Property Records9
▸DOB NOWZoning Exhibit form (1-5)4
08/13/2026B00789072-P3Open ↗
08/13/2026B00789072-P2Open ↗
08/13/2026B00789072-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWZD1: DOB Zoning Diagram4
08/13/2026B00789072-I1Open ↗
08/13/2026B00789072-P3Open ↗
08/13/2026B00789072-P2Open ↗
Showing 3 of 4 on file for this type
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED1
03/28/2023340883672Open ↗
▸Seals & Professional Certifications21
▸DOB NOWDPL-1: Design Professional Seal & Signature15
08/28/2026B00789072-P1Open ↗
08/28/2026B00789072-I1Open ↗
08/28/2026B00789072-S1Open ↗
Showing 3 of 15 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
08/28/2026B00789072-S4Open ↗
08/25/2026B00789072-S1Open ↗
08/24/2026B00789072-S3Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
03/28/2023340883672Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
03/28/2023340883672Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/28/2026B00789072-S4Open ↗
▸Trade Schedules & Equipment5
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)4
08/13/2026B00789072-P3Open ↗
08/13/2026B00789072-I1Open ↗
08/13/2026B00789072-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWStandpipe Alarms Drawings1
08/15/2026B00789072-I1—
▸Safety & Tenant Protection6
▸DOB NOWStreet Tree Checklist4
08/28/2026B00789072-P1Open ↗
08/15/2026B00789072-I1Open ↗
08/15/2026B00789072-P3Open ↗
Showing 3 of 4 on file for this type
▸BISBPP: STREET TREES SITE PLAN1
03/28/2023340883672Open ↗
▸BISSTREET TREE CHECKLIST1
03/28/2023340883672Open ↗
▸Inspections & Test Reports4
▸DOB NOWSOIL REPORT4
08/13/2026B00789072-P1Open ↗
08/13/2026B00789072-I1Open ↗
08/13/2026B00789072-P2Open ↗
Showing 3 of 4 on file for this type
▸Filing & Intake Forms2
▸BISEFILING JOB APPLICATION COVER SHEET1
03/28/2023340883672Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
03/06/2024340883672Open ↗
▸Other Documents14
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone4
08/13/2026B00789072-P2Open ↗
08/13/2026B00789072-P1Open ↗
08/13/2026B00789072-P3Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSite Survey: Initial4
08/13/2026B00789072-P2Open ↗
08/13/2026B00789072-P3Open ↗
08/13/2026B00789072-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProperty Ownership Certification4
08/28/2026B00789072-P1Open ↗
08/15/2026B00789072-I1Open ↗
08/15/2026B00789072-P3Open ↗
Showing 3 of 4 on file for this type
▸BISRECORDS MGMT FEE PAYMENT RECEIPT1
04/11/2024340883672Open ↗
▸DOB NOWAdjoining Owners Notification1
08/14/2026B00789072-S7Open ↗