← Back
Two stories - detached, small or mid-size
273 COLLEGE AVENUE
STATEN ISLAND · Westerleigh-Castleton Corners · BIN 5010016
💬 Discuss this project
1915Year Built
2Stories
A1Building Class
R2Zoning
1,244 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 3,600 sf lot · 0.35 FAR built · Flood zone X
Locations of Work
Architecture
Cellar1p · 1 filing · 2 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CHRIS PONISI, ARCHITECT309/15/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
DAWN PONISI303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TROOST BROS INCGeneral Contractor403/21/2026
LOUIS L.BUTTERMARK & SONSPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
A TECH ENGINEERING NYC, P6738309/15/2022
Building Lifecycle
All (23)Filed (3)Permit Issued (2)Inspection (4)Special Inspection (14)
03/22/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
03/07/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
12/09/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/09/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
11/16/2022
Permit issued — Plumbing
S00792253-S1-PL
11/09/2022
Permit issued — Foundation
S00792254-I1-GC-CX
09/15/2022
Filed — Alteration
APPLICATION FILED FOR NEW PLUMBING WORK IN CONJUNCTION WITH ALTERATION APPLICATION #S00792253-I1
S00792253-S1
09/06/2022
Filed — Alteration
APPLICATION FILED FOR NEW PLUMBING WORK IN CONJUNCTION WITH ALTERATION APPLICATION #S00792253-I1
S00792253-I1
09/06/2022
Special inspection requirement — Energy Code Compliance Inspections
anthony santoro
09/06/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
anthony santoro
09/01/2022
Special inspection requirement — Fire-Resistance Rated Construction
anthony santoro
09/01/2022
Special inspection requirement — Energy Code Compliance Inspections
anthony santoro
09/01/2022
Special inspection requirement — Structural Wood Frame
anthony santoro
09/01/2022
Special inspection requirement — Air barrier - visual inspection
anthony santoro
09/01/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
anthony santoro
09/01/2022
Special inspection requirement — Fenestration areas
anthony santoro
09/01/2022
Special inspection requirement — Insulation placement and R values
anthony santoro
09/01/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
anthony santoro
09/01/2022
Special inspection requirement — Interior lighting power
anthony santoro
09/01/2022
Special inspection requirement — Fenestration air leakage
anthony santoro
09/01/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
anthony santoro
08/26/2022
Filed — Alteration
S00792254-I1
08/12/2022
Special inspection requirement — Final
anthony santoro
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offLOUIS L BUTTERMARK&SONS I11/16/2022
DOB NOWFoundationSigned-offTROOST BROS INC11/09/2022
1 project · most recent 12/26/2022
General Wiring
FiledStatusContractorScope
12/26/2022CompleteRIDGE ELECTRIC CORP.General Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
03/22/2023Pass-Final General Construction Non-Directive 14PassView ↗
03/07/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
12/09/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/09/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 14
DateRequirementInspectorRole
09/06/2022Energy Code Compliance Inspectionsanthony santoroprogress
09/06/2022Fire-Resistant Penetrations and Jointsanthony santorospecial
09/01/2022Fire-Resistance Rated Constructionanthony santoroprogress
09/01/2022Energy Code Compliance Inspectionsanthony santoroprogress
09/01/2022Structural Wood Frameanthony santoroprogress
09/01/2022Air barrier - visual inspectionanthony santoroenergy_progress
09/01/2022Fire-Resistant Penetrations and Jointsanthony santorospecial
09/01/2022Fenestration areasanthony santoroenergy_progress
09/01/2022Insulation placement and R valuesanthony santoroenergy_progress
09/01/2022Fenestration and door U-factor and product ratingsanthony santoroenergy_progress
09/01/2022Interior lighting poweranthony santoroenergy_progress
09/01/2022Fenestration air leakageanthony santoroenergy_progress
09/01/2022Structural Stability – Alterations of existing buildingsanthony santorospecial
08/12/2022Finalanthony santoroprogress
▾Documents — 15 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/24/2026S00792253-I1Request digital key ↗
08/24/2026S00792253-S1Request digital key ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWRestrictive Declaration/Easement 12
08/13/2026S00792253-S1Open ↗
08/13/2026S00792253-I1Open ↗
▸Seals & Professional Certifications8
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/13/2026S00792254-I1Open ↗
08/13/2026S00792253-S1Open ↗
08/13/2026S00792253-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature3
08/29/2026S00792253-I1Open ↗
08/29/2026S00792253-I1Open ↗
08/26/2026S00792253-S1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/29/2026S00792253-I1Open ↗
08/26/2026S00792253-S1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/13/2026S00792254-I1Open ↗
08/13/2026S00792253-I1Open ↗
08/13/2026S00792253-S1Open ↗