ECB05/27/2026Failure to comply with the commissioner's order to file a certificate of correction with the dept of buildings for summons 39518005Z, file a certificate of correction$1K due
ECB05/27/2026Failure to comply with the commissioner's order to file a certificate of correction with the dept of buildings for summons 39518154M., file a certificate of correction$1K due
ECB05/27/2026Failure to comply with commissioner's order in DOB violation VI023-01897 dated 06/20/2023. Responded was required to submit an engineer's report concerning structurally deficient conditions. As of 05/27/2026, a$6K due
DOB07/09/2024Full vacate/failure to maintain bldg in a safe condition.EXP1&EXP4 had various step cracks@windows.EXP4 severe vert crack@1STFL near 1/4 store windw crnr&step crack emanatng up towards 2NDFL.fully vacate bldg until hazardous cnditions have perm remedied undr prmt.ownr to rtain nyspe to eval ent bldg
DOB11/22/2023Failure to certify correction on immediately hazardous (class 1) ECB violationIssued 2023; DOB's record still lists it as active
ECB10/11/2023Failure to comply with the commissioner's order in DOB violation VIO23-01897,dated 6/20/2023.respondent was required to submit an engineer'sreport concerning structurally deficient conditions.as of 10/11/2023,a$12K due
ECB06/22/2023There are step cracks and a serious vertical crack at exp. 4 . The walls at both sides of entry door are clearly out of plumb. The awning structure could be covering more faults.$25K due
ECB06/20/2023Failure to maintain building in code-compliant manner. Failure to maintqain building in code compliant manner. Noted: observed at exposure # 4 there are vertical and horizontal cracks on the ground floor going$1K due
ECB04/24/2021Failure to maintain bldg walls or appurtenances. At the time of inspection & observed at exp#4 facing lincoln place,below 2ND fl window & 1ST fl sty windows vertical cracks approx 10'0 & stepping pettern bricks$25K due
ECB12/15/2020Reissue #35502907 issued on 09/14/2020:failure to maintain bldg walls or appurtenances at the time of inspection & observed at exp#4 facing lincoln place just below 2ND fl window vertical cracks approx. 10' at$25K due
ECB01/30/2020Failure to maintain buidling walls or appurtannces noted at exposure 1 + 4 with vertical and horizontal cracks throughout in various locations and stepcracks previous ECB #35459188H maintain exterior building w$1K due
ECB12/09/2019Failure to maintain bldg walls or appurtenances. Noted: observed at exp#4 on the right side of the bldg. The are vertical & horizontal cracks on the wall from the 1ST fl to the 2ND fl. Also at front of bldg at$1K due
ECB10/16/2019Failure to maintain bldg exterior walls or appurtenances. Note: at exp#4 there are vertical & horizontal cracks & seperations in the brick mortar. Previous ECB#35422385M. Remedy: maintain exterior bldg walls &$1K due
ECB07/13/2019Failure to maintain building walls or appurtenances. Noted: at exp.4 observed vertical and horizontal cracks/separation in brick/mortar wall. Previous ECB #35422385H remedy: maintain exterior building walls$6K due
ECB05/02/2019Failure to maintain bldg walls or appurtenances. At the time of inspection noted: at exp#4(right side of bldg)horizontal & vertical cracks between mortar joints & running down the bricks. Condition recurring.$6K due
ECB03/06/2019Failure to maintain building wall(s) on appurtenances. At exp#4 verti cal and horizontal cracks. Rmdy: maintain building walls.$6K due
ECB01/08/2019Failure to maintain bldg wall(s)or appurtenances at exp #4 vertical and horizontal cracks upto 2ND floor from ground level also 1 crack up by 2ND fl level right corner exp #2/rem:maintain bldg walls$25K due
ECB11/28/2018Failure to maintain building walls or appurtenance:note at exposure#4 from ground level up vertical and horizontal cracks to 2ND fl. Also atexposure#1 entrance door leading to apts leaning to right. Remedy:main$25K due
ECB10/15/2018Failure to maintain bldg walls or appurtenances. Noted: observed at exp#4 from around level vertical & horizontal cracks to 2ND fl. Also at exp#1 the entrance door to the apt is leaning toward the right & is$6K due
ECB09/08/2018Reissue vio#35335499K failure to maintain bldg walls or appurtenances.note: at exp#4 ground level verticval & horizontal cracks 1/4(width approx). Remedy: maintain exterior bldg wall.$12K due
HPD05/15/2013§ 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES LOCATED AT APT 2, 1st APARTMENT FROM NORTH AT EAST
HPD05/15/2013§ 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE LOCATED AT APT 2, 1st APARTMENT FROM NORTH AT EAST
HPD05/15/2013§ 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
ECB02/09/2018Failure to maintain bldg walls or appurtenances. Noted: at EXP34 thereare vertival cracks from the ground up to the 2ND fl. At exp#1 the entrance door to the apts is leaning towards the right & is not plumb.Nothing owed — awaiting certificate of correction
ECB12/27/2017Failure to maintain bldg walls or appurtenances. Noted: at exp#4 thereare vertical cracks from the ground to the 2ND fl. At exp#1 the entrance door to the apt is leaning towards the right & is not plumb.Nothing owed — awaiting certificate of correction
ECB11/03/2017Failure to maintain building wall(s) or appurtenances. Noted: at exposure #4 there are vertical cracks from the ground to the second floor. At exposure #1 the entrance door to the apartments is leaning towardsNothing owed — awaiting certificate of correction
ECB09/16/2017Failure to maintain bldg wall(s)or appurtenances.noted:vertical cracks from grd to 2ND fl at exp#4 and addtl cracks on exp#1 various locations.entrance door to apt at exp#1 is leaning towards right.rem:maintainNothing owed — awaiting certificate of correction
ECB07/26/2017Failure to maintain bldg walls or appurtenances. Noted: bldg has vertical cracks at exp#1 & 4 from 1ST fl to 3RD fl(step cracks)also at parapet. Remedy: comply w/the code.Nothing owed — awaiting certificate of correction
ECB05/31/2017Failure to maintain bldg in a code compliant manner: use of prohibited door &/or hardware per bc 1008.1.8 & 27-371(j). Noted: metal fence doors at ext 4 have dead bolt locks w/latches installed that can be lockNothing owed — awaiting certificate of correction
ECB05/31/2017Failure to maintain bldg walls or appurtenances. Noted: bldg walls at exp#1 & 4 are shifing towards street corner,multiple continuous step cracks from 3RD to 1ST fl at exp#1&4,step cracks at parapet corner ofNothing owed — awaiting certificate of correction
ECB03/01/2017Failure to maintain walls or appurtenances.observed vertical crack from ground to 2ND flr on expo#4.also additional cracks on EXPO31 at 2ND level and at roof on expo#4.observed apt entrance door at expo#1 leaniNothing owed — awaiting certificate of correction
ECB01/28/2017Failure to provide unobstructed exit passageway. Noted: fire escape located along lincoln pl section of the bldg & terminates behind an erected fence approx 10FEET higher totally obstructing a safe place of refNothing owed — awaiting certificate of correction
ECB01/28/2017Failure to maintain. Noted: exterior brick wall (kingston ave section)in disrepair w/step cracks at both 2ND & 3RD fl levels. Sill at 3RD level also show displacement. 1ST fl level of bldg,there is evidence ofNothing owed — awaiting certificate of correction
ECB08/29/2016Failure to provide unobstructed exit passageway.observed fire escape on exposure 3 is enclosed behind a metal fence erected apprx 10'high.also behind same fence is large pile of combustibles including but notNothing owed — awaiting certificate of correction
ECB03/18/2016Work w/o a permit. Work noted: at exp#4(lincoln pl)erected approx 50'long x 10'high x 3'wide steel enclosure w/entry doors & roll down gate.remedy: obtain all necessary permits.Nothing owed — awaiting certificate of correction
ECB08/20/2013Splices made are not properly covered. Basement. Remedy: comply w/ec code.Nothing owed — awaiting certificate of correction
ECB08/07/2013Unapproved/unsafe/unsuitable electrical equipment. Apparatus, materials,devices,appliances or wiring in use. Defective fixtures,outlets,bx not terminated and flex cord used as permanent wiring. Entire basementNothing owed — awaiting certificate of correction
ECB08/07/2013Sec. Ec 300.3B. Raceway is not provided for open conductors, open wiring. Raceway is not provided for physical protection of conductors basement. Remedy: comply w/ec code.Nothing owed — awaiting certificate of correction
ECB08/07/2013Failure to provide/maintain sufficient access/work space about electrical equipment. Min work space is not provided in front of electrical equipment basement. Remedy: provide/maintain access/work space.Nothing owed — awaiting certificate of correction
ECB02/04/2011Work does not conform to approved plan & alt ii 310303043 - for the installation of a 101 fence. (chain link) & metal rollup gate. Fence is corrugated steel & plan indicates sidewalk measurement is 15'from bldgNothing owed — awaiting certificate of correction
ECB04/07/2006Work w/o a permit- hazardous, work noted; in commercial store at ground level a suspended ceiling was installed, measuring approx. 30 ft by 13 ft & hanging aprrox. 2FT from ceiling w/small gauge wire. Remedy: oNothing owed — awaiting certificate of correction
Old · issued 3+ years ago and still listed by DOB; nothing on the city's records either way
DOB10/04/2023Failure to certify correction on immediately hazardous (class 1) ECB violationIssued 2023; DOB's record still lists it as active
DOB08/02/2023Failure to file benchmarking report of energy use as per ad. Code sec. 28-309.4Issued 2023; DOB's record still lists it as active
DOB06/20/2023Failure to maintain building in code compliant manner . The occupied building structure with concrete framing observed to be in a state of disrepair .cracks , with cracks at various location.Issued 2023; DOB's record still lists it as active
DOB05/02/2023Failure to file benchmarking report of energy use as per ad. Code sec. 28-309.4Issued 2023; DOB's record still lists it as active
DOB07/21/2021Failure to certify correction on immediately hazardous (class 1) ECB violationIssued 2021; DOB's record still lists it as active
DOB03/17/2021Failure to certify correction on immediately hazardous (class 1) ECB violationIssued 2021; DOB's record still lists it as active
DOB10/17/2019Failure to certify correction on immediately hazardous (class 1) ECB violationIssued 2019; DOB's record still lists it as active
DOB04/03/2019Failure to certify correction on immediately hazardous (class 1) ECB violationIssued 2019; DOB's record still lists it as active
DOB03/06/2019Failure to certify correction on immediately hazardous (class 1) ECB violationIssued 2019; DOB's record still lists it as active
DOB01/09/2019Failure to certify correction on immediately hazardous (class 1) ECB violationIssued 2019; DOB's record still lists it as active
DOB11/28/2018Failure to certify correction on immediately hazardous (class 1) ECB violationIssued 2018; DOB's record still lists it as active
DOB05/02/2018Failure to certify correction on immediately hazardous (class 1) ECB violationIssued 2018; DOB's record still lists it as active
DOB01/24/2018Failure to certify correction on immediately hazardous (class 1) ECB violationIssued 2018; DOB's record still lists it as active
DOB08/23/2017Failure to certify correction on immediately hazardous (class 1) ECB violationIssued 2017; DOB's record still lists it as active
DOB04/19/2017Failure to certify correction on immediately hazardous (class 1) ECB violationIssued 2017; DOB's record still lists it as active2 identical filings
DOB11/30/2016Failure to certify correction on immediately hazardous (class 1) ECB violationIssued 2016; DOB's record still lists it as active