← Back
Two family brick
2731 FENTON AVENUE
BRONX · Pelham Gardens · BIN 2054480
💬 Discuss this project
1950Year Built
1Stories
B1Building Class
R4Zoning
1,753 sfGross Floor Area
2Units
Two family brick · 2,200 sf lot · 0.8 FAR built · Flood zone X
Locations of Work
ArchitectureElectrical
Roof6p · 1 filing · 15 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/13/2019$495K—— → —$282/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC209/17/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SUNCO CAPITAL403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SUNCO CAPITAL LLCGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854209/17/2025
Building Lifecycle
All (18)Filed (2)Permit Issued (1)Signed Off (1)Objection (2)Special Inspection (12)
10/27/2025
Signed off — Alteration
INSTALLATION OF SOLAR PANELS ON ROOF. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
X01262148-I1
09/24/2025
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
TOM PETERSEN
09/24/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
09/24/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
09/24/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
09/24/2025
Special inspection requirement — Final
TOM PETERSEN
09/24/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
09/17/2025
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON ROOF. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
X01262148-P1
09/17/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
09/17/2025
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
TOM PETERSEN
09/17/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
09/17/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
09/17/2025
Special inspection requirement — Final
TOM PETERSEN
09/17/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
08/15/2025
Permit issued — Solar
X01262148-I1-SL
08/01/2025
Objection resolved — Addressed
07/31/2025
Objection raised — Admin
07/29/2025
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON ROOF. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
X01262148-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offSUNCO CAPITAL LLC08/15/2025
2 projects · most recent 07/28/2025
FiledStatusContractorScope
07/28/2025CompleteBERGER QUALITY ELEC'L CON—
10/17/2019CompleteMACK ELECTRICAL INC2 meters
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
09/24/2025Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)TOM PETERSENspecial
09/24/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
09/24/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
09/24/2025Energy Code Compliance InspectionsTOM PETERSENprogress
09/24/2025FinalTOM PETERSENprogress
09/24/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
09/17/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
09/17/2025Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)TOM PETERSENspecial
09/17/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
09/17/2025Energy Code Compliance InspectionsTOM PETERSENprogress
09/17/2025FinalTOM PETERSENprogress
09/17/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 15 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/18/2026X01262148-P1Request digital key ↗
08/18/2026X01262148-I1Request digital key ↗
▸Seals & Professional Certifications10
▸DOB NOWProgress Inspector Seal & Signature4
08/24/2026X01262148-P1Open ↗
08/24/2026X01262148-P1Open ↗
08/23/2026X01262148-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/24/2026X01262148-P1Open ↗
08/24/2026X01262148-P1Open ↗
08/23/2026X01262148-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026X01262148-P1Open ↗
08/13/2026X01262148-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026X01262148-P1Open ↗
08/13/2026X01262148-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026X01262148-I1Open ↗