← Back
Three families
274 PROSPECT PLACE
BROOKLYN · Prospect Heights · BIN 3028801
💬 Discuss this project
1896Year Built
2Stories
C0Building Class
R6BZoning
2,748 sfGross Floor Area
3Units
Rent Stabilized2 Open Violations ▸FDNY Report ↗
Three families · 2,620 sf lot · 1.05 FAR built · Flood zone X
Locations of Work
Plumbing
Roof9p · 1 filing · 11 docs
Floor 29p · 1 filing · 11 docs
Floor 19p · 1 filing · 11 docs
Cellar9p · 1 filing · 11 docs
Sub-Basement9p · 1 filing · 11 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/28/2019$2.1M—— → —$773/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
RAAD201/05/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
MK ARCHITECTURE PC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
RVM PLUMBING CORPPlumbing207/08/2026
MODERN TREND ELECL CONTRGElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
GRANT ENGINEERING2627201/05/2023
Building Lifecycle
All (26)Filed (2)Permit Issued (2)Signed Off (1)Violation (17)Inspection (2)Special Inspection (2)
04/11/2024
Violation issued (HPD, closed)
A
11/22/2023
Violation issued (HPD, closed)
I
08/01/2023
Signed off — Alteration
Re-filing plumbing scope to supersede initial filing B00312199-I1. No change to use, occupancy or egress.
B00312199-S2
03/24/2023
Violation issued (HPD, closed)
A
01/25/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/23/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/12/2023
Permit issued — Plumbing
B00312199-S2-PL
01/05/2023
Filed — Alteration
Re-filing plumbing scope to supersede initial filing B00312199-I1. No change to use, occupancy or egress.
B00312199-S2
11/14/2022
Violation issued (HPD, closed)
I
03/01/2022
Violation issued (HPD, closed)
I
03/01/2022
Violation issued (HPD, closed)
A
04/12/2021
Violation issued (HPD, closed)
I
04/12/2021
Violation issued (HPD, closed)
A
07/20/2020
Permit issued — Plumbing
B00312199-I1-PL
03/05/2020
Filed — Alteration
Re-filing plumbing scope to supersede initial filing B00312199-I1. No change to use, occupancy or egress.
B00312199-I1
03/05/2020
Special inspection requirement — Fire-Resistant Penetrations and Joints
Stephen Morse
03/05/2020
Special inspection requirement — Fire-Resistance Rated Construction
NICHOLAS AZADIAN
02/05/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/04/2019
Violation issued (ECB, closed)
Construction
10/19/2018
Violation issued (HPD, closed)
I
11/28/2017
Violation issued (HPD, closed)
I
11/14/2016
Violation issued (HPD, closed)
I
10/13/2015
Violation issued (HPD, closed)
I
02/24/2015
Violation issued (HPD, closed)
I
05/15/2006
Violation issued (HPD, open)
B
06/03/1976
Violation issued (HPD, open)
A
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offRVM PLUMBING CORP01/12/2023
DOB NOWPlumbingPermit IssuedRVM PLUMBING CORP07/20/2020
BISOTISSUEDSUNKEEPER SOLAR ELECTRIC08/20/2020
1 project · most recent 01/05/2023
Gas Water/Sanitary
FiledStatusContractorScope
01/05/2023Signed-offRVM PLUMBING CORPGas, Water/Sanitary
2 projects · most recent 08/03/2021
General Wiring
FiledStatusContractorScope
08/03/2021Permit IssuedMODERN TREND ELECL CONTRGGeneral Wiring
11/26/2019CompleteMODERN TREND ELECL CONTRG—
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
01/25/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/23/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
03/05/2020Fire-Resistant Penetrations and JointsStephen Morsespecial
03/05/2020Fire-Resistance Rated ConstructionNICHOLAS AZADIANprogress
▾Documents — 31 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch1
08/28/2026B00312199-S2Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing Legalization1
08/28/2026B00312199-I1Request digital key ↗
▸Applications & Permits4
▸DOB NOWLPC Approval/Permit2
08/13/2026B00312199-S2Open ↗
08/13/2026B00312199-I1Open ↗
▸BISWORK PERMIT APPLICATION1
08/20/2020340716309Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
02/10/2020340716309Open ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026B00312199-I1Open ↗
08/13/2026B00312199-S2Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
02/10/2020340716309Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/24/2026B00312199-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/24/2026B00312199-I1Open ↗
▸Safety & Tenant Protection2
▸BISTENANT PROTECTION PLAN AND NOTES1
02/11/2020340716309Open ↗
▸DOB NOWTenant Protection Plan1
08/13/2026B00312199-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026B00312199-S2Open ↗
08/13/2026B00312199-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
02/10/2020340716309Open ↗
▸Energy Compliance5
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
10/25/2021340716309Open ↗
02/10/2020340716309Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
10/25/2021340716309Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)1
02/10/2020340716309Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (FINAL)1
10/25/2021340716309Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
10/25/2021340716309Open ↗
02/10/2020340716309Open ↗
▸Approvals, Objections & Sign-offs5
▸BISLETTERS - SUPPORTING DOCUMENTATION2
10/25/2021340716309Open ↗
05/19/2020340716309Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
10/25/2021340716309Open ↗
▸BISLANDMARKS SIGNOFF1
10/25/2021340716309Open ↗
▸BISLANDMARKS APPROVAL1
02/10/2020340716309Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
10/25/2021340716309Open ↗
02/10/2020340716309Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
02/10/2020340716309Open ↗