← Back
Over six families without stores
2740 SEXTON PLACE
BRONX · BIN 2055342
💬 Discuss this project
1931Year Built
2Stories
C1Building Class
R4Zoning
3,700 sfGross Floor Area
8Units
15 Open Violations 7 unresolved · 8 paperwork only ▸
Over six families without stores · Owner of record: 2740 SEXTON PLACE LLC · 2,375 sf lot · 1.56 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
1 job · most recent 05/01/2025
General Wiring
FiledStatusContractorScope
05/01/2025Permit IssuedMAX ELECTRIC CO., INCGeneral Wiring
Building Lifecycle
All (55)Filed (6)Permit Issued (6)Signed Off (4)Violation (18)Inspection (3)Special Inspection (18)
06/06/2025
Signed off — Alteration
Installation of eight (8) split system heat pumps to supply exisitng 8 dwelling unit residential building. No change in use, egress or occupancy.
X01002476-S2
03/11/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
03/04/2025
Signed off — Alteration
Installation of eight (8) split system heat pumps to supply exisitng 8 dwelling unit residential building. No change in use, egress or occupancy.
X01002476-S1
03/03/2025
Signed off — Alteration
Installation of eight (8) split system heat pumps to supply exisitng 8 dwelling unit residential building. No change in use, egress or occupancy.
X01002476-I1
03/03/2025
Signed off — Alteration
Installation of eight (8) split system heat pumps to supply exisitng 8 dwelling unit residential building. No change in use, egress or occupancy.
X01002476-S4
02/28/2025
Permit issued — Mechanical Systems
X01002476-S4-MS
02/21/2025
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
02/06/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jose Santos
02/06/2025
Special inspection requirement — Maintenance information
Jose Santos
02/06/2025
Special inspection requirement — Interior lighting power
Jose Santos
02/06/2025
Special inspection requirement — Lighting controls
Jose Santos
02/06/2025
Special inspection requirement — Lighting in dwelling units
Jose Santos
02/06/2025
Special inspection requirement — Air barrier - visual inspection
Jose Santos
01/31/2025
Filed — Alteration
Installation of eight (8) split system heat pumps to supply exisitng 8 dwelling unit residential building. No change in use, egress or occupancy.
X01002476-P2
01/30/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jose Santos
01/30/2025
Special inspection requirement — Lighting controls
Jose Santos
01/30/2025
Special inspection requirement — Lighting in dwelling units
Jose Santos
01/30/2025
Special inspection requirement — Air barrier - visual inspection
Jose Santos
01/30/2025
Special inspection requirement — Interior lighting power
Jose Santos
01/30/2025
Special inspection requirement — Maintenance information
Jose Santos
11/13/2024
Filed — Alteration
Installation of eight (8) split system heat pumps to supply exisitng 8 dwelling unit residential building. No change in use, egress or occupancy.
X01002476-S4
10/24/2024
Filed — Alteration
Installation of eight (8) split system heat pumps to supply exisitng 8 dwelling unit residential building. No change in use, egress or occupancy.
X01002476-P1
10/24/2024
Permit issued — General Construction
X01002476-S1-GC
08/08/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/23/2024
Permit issued — Plumbing
X01002476-S2-PL
07/01/2024
Permit issued — General Construction
X01002476-S1-GC
05/01/2024
Permit issued — General Construction
X01002476-S1-GC
04/25/2024
Filed — Alteration
Installation of eight (8) split system heat pumps to supply exisitng 8 dwelling unit residential building. No change in use, egress or occupancy.
X01002476-S2
04/24/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jose Santos
04/24/2024
Special inspection requirement — Energy Code Compliance Inspections
Jose Santos
04/24/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Jose Santos
04/24/2024
Special inspection requirement — Maintenance information
Jose Santos
04/24/2024
Special inspection requirement — HVAC-R and service water heating system controls
Jose Santos
04/24/2024
Special inspection requirement — HVAC-R and service water heating equipment
Jose Santos
03/11/2024
Filed — Alteration
Installation of eight (8) split system heat pumps to supply exisitng 8 dwelling unit residential building. No change in use, egress or occupancy.
X01002476-S1
02/16/2024
Permit issued — Construction Fence
X01002476-I1-FN
02/12/2024
Filed — Alteration
Installation of eight (8) split system heat pumps to supply exisitng 8 dwelling unit residential building. No change in use, egress or occupancy.
X01002476-I1
07/25/2023
Violation issued (DOB, closed)
V%*-DOB VIOLATION - DISMISSED
03/16/2022
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/19/2022
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
12/16/2021
Violation issued (ECB, open)
Construction
11/24/2021
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
10/18/2021
Violation issued (ECB, open)
Construction
09/15/2021
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
08/31/2021
Violation issued (ECB, open)
Construction
07/21/2021
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/15/2021
Violation issued (ECB, open)
Construction
05/26/2021
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/28/2021
Violation issued (ECB, open)
Construction
04/15/2021
Violation issued (ECB, open)
Construction
03/05/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/04/2021
Violation issued (ECB, open)
Construction
02/17/2021
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/30/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/29/2020
Violation issued (ECB, open)
Construction
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BABA CONSTRUCTION2207/08/2026
2740 SEXTON PLACE LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/16/2024$700K—— → —$189/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
COLOMBO ARCHITECTURAL STUDIO PC601/31/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BABA CONSTRUCTION CORPGeneral Contractor1107/08/2026
HUDSON RIVER MECH GROUP IPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JOSE A SANTOS PE, PC3292401/31/2025
COLOMBO ARCHITECTURAL STU4930111/13/2024
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offBABA CONSTRUCTION CORP02/28/2025
DOB NOWGeneral ConstructionSigned-offBABA CONSTRUCTION CORP10/24/2024
DOB NOWPlumbingSigned-offHUDSON RIVER MECH GROUP I07/23/2024
DOB NOWGeneral ConstructionSigned-offBABA CONSTRUCTION CORP07/01/2024
DOB NOWGeneral ConstructionSigned-offBABA CONSTRUCTION CORP05/01/2024
DOB NOWConstruction FenceSigned-offBABA CONSTRUCTION CORP02/16/2024
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
03/11/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/21/2025Pass-Final General Construction Non-Directive 14PassView ↗
08/08/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 18
DateRequirementInspectorRole
02/06/2025Fire-Resistant Penetrations and JointsJose Santosspecial
02/06/2025Maintenance informationJose Santosenergy_progress
02/06/2025Interior lighting powerJose Santosenergy_progress
02/06/2025Lighting controlsJose Santosenergy_progress
02/06/2025Lighting in dwelling unitsJose Santosenergy_progress
02/06/2025Air barrier - visual inspectionJose Santosenergy_progress
01/30/2025Fire-Resistant Penetrations and JointsJose Santosspecial
01/30/2025Lighting controlsJose Santosenergy_progress
01/30/2025Lighting in dwelling unitsJose Santosenergy_progress
01/30/2025Air barrier - visual inspectionJose Santosenergy_progress
01/30/2025Interior lighting powerJose Santosenergy_progress
01/30/2025Maintenance informationJose Santosenergy_progress
04/24/2024Fire-Resistant Penetrations and JointsJose Santosspecial
04/24/2024Energy Code Compliance InspectionsJose Santosprogress
04/24/2024HVAC-R and service water piping design and insulationJose Santosenergy_progress
04/24/2024Maintenance informationJose Santosenergy_progress
04/24/2024HVAC-R and service water heating system controlsJose Santosenergy_progress
04/24/2024HVAC-R and service water heating equipmentJose Santosenergy_progress
▾Documents — 25 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/21/2026X01002476-P1Request digital key ↗
08/21/2026X01002476-S4Request digital key ↗
08/21/2026X01002476-S2Request digital key ↗
Showing 3 of 7 on file for this type
▸Seals & Professional Certifications12
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/21/2026X01002476-S4Open ↗
08/21/2026X01002476-S2Open ↗
08/21/2026X01002476-S1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
08/26/2026X01002476-S1Open ↗
08/26/2026X01002476-P2Open ↗
08/24/2026X01002476-S2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
08/26/2026X01002476-S1Open ↗
08/26/2026X01002476-P2Open ↗
08/24/2026X01002476-S2Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/21/2026X01002476-S4Open ↗
08/21/2026X01002476-S2Open ↗
08/21/2026X01002476-S1Open ↗
Showing 3 of 6 on file for this type