← Back
Miscellaneous two family
2746 MILL AVENUE
BROOKLYN · BIN 3242511
💬 Discuss this project
1960Year Built
3Stories
B9Building Class
R5Zoning
1,938 sfGross Floor Area
2Units
Miscellaneous two family · 1,792 sf lot · 1.08 FAR built · Flood zone AE
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/04/2021$965K—— → —$498/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ARC CONSULTING ENGINEERS403/19/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BASIC GROUPS803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DYKER SOLUTIONS INCGeneral Contractor107/08/2026
DPH PLUMBING & HTG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ARC CONSULTING ENGINEERS,4083403/19/2024
Building Lifecycle
All (21)Filed (4)Permit Issued (2)Signed Off (2)Inspection (7)Special Inspection (6)
06/12/2024
Signed off — Alteration
PLUMBING WORK AS PER PLAN FILED HEREWITH. NO CHANGE IN USE, OCCUPANCY, OR EGRESS OF THE BUILDING.
B00966331-I1
06/05/2024
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
04/30/2024
Signed off — Alteration
PLUMBING WORK AS PER PLAN FILED HEREWITH. NO CHANGE IN USE, OCCUPANCY, OR EGRESS OF THE BUILDING.
B00966331-S1
04/24/2024
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
04/12/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
04/10/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/22/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
JAN PEREZ
03/22/2024
Special inspection requirement — Energy Code Compliance Inspections
JAN PEREZ
03/19/2024
Filed — Alteration
PLUMBING WORK AS PER PLAN FILED HEREWITH. NO CHANGE IN USE, OCCUPANCY, OR EGRESS OF THE BUILDING.
B00966331-P2
01/22/2024
Filed — Alteration
PLUMBING WORK AS PER PLAN FILED HEREWITH. NO CHANGE IN USE, OCCUPANCY, OR EGRESS OF THE BUILDING.
B00966331-P1
01/22/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
JAN PEREZ
01/22/2024
Special inspection requirement — Energy Code Compliance Inspections
JAN PEREZ
12/22/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
12/22/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/22/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
11/30/2023
Permit issued — General Construction
B00966331-I1-GC
11/27/2023
Permit issued — Plumbing
B00966331-S1-PL
11/23/2023
Filed — Alteration
PLUMBING WORK AS PER PLAN FILED HEREWITH. NO CHANGE IN USE, OCCUPANCY, OR EGRESS OF THE BUILDING.
B00966331-I1
11/23/2023
Filed — Alteration
PLUMBING WORK AS PER PLAN FILED HEREWITH. NO CHANGE IN USE, OCCUPANCY, OR EGRESS OF THE BUILDING.
B00966331-S1
11/22/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
JAN PEREZ
11/22/2023
Special inspection requirement — Energy Code Compliance Inspections
JAN PEREZ
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offDYKER SOLUTIONS11/30/2023
DOB NOWPlumbingSigned-offDPH PLUMBING & HTG CORP11/27/2023
1 project · most recent 12/17/2023
General Wiring
FiledStatusContractorScope
12/17/2023Permit IssuedFOSTER ELEC'L SVC., INC.General Wiring
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
06/05/2024Pass-Final General Construction Non-Directive 14PassView ↗
04/24/2024Fail-Final General Construction Non-Directive 14FailView ↗
04/12/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/10/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/22/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/22/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/22/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
03/22/2024Fire-Resistant Penetrations and JointsJAN PEREZspecial
03/22/2024Energy Code Compliance InspectionsJAN PEREZprogress
01/22/2024Fire-Resistant Penetrations and JointsJAN PEREZspecial
01/22/2024Energy Code Compliance InspectionsJAN PEREZprogress
11/22/2023Fire-Resistant Penetrations and JointsJAN PEREZspecial
11/22/2023Energy Code Compliance InspectionsJAN PEREZprogress
▾Documents — 20 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/26/2026B00966331-P2Request digital key ↗
08/26/2026B00966331-P1Request digital key ↗
08/26/2026B00966331-S1Request digital key ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWRestrictive Declaration/Easement 12
08/26/2026B00966331-S1Open ↗
08/13/2026B00966331-P2Open ↗
▸Seals & Professional Certifications10
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/26/2026B00966331-P1Open ↗
08/26/2026B00966331-S1Open ↗
08/13/2026B00966331-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
09/02/2026B00966331-P1Open ↗
08/27/2026B00966331-S1Open ↗
08/25/2026B00966331-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature3
09/02/2026B00966331-P1Open ↗
08/27/2026B00966331-S1Open ↗
08/25/2026B00966331-I1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/26/2026B00966331-P1Open ↗
08/26/2026B00966331-S1Open ↗
08/13/2026B00966331-P2Open ↗
Showing 3 of 4 on file for this type