← Back
Two family brick
2747 HARING STREET
💬 Discuss this project
2001Year Built
2Stories
B1Building Class
R3-2Zoning
—Gross Floor Area
2Units
0 Open Violations
Two family brick · 0.76 FAR built · Flood zone X500
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
LINFO REALTY203/22/2026
LINFO REALTY CO LTC103/22/2026
OWNER OF PREMISES = 2743103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
GERALD CALIENDO ARCHITECTS109/15/2026
Building Lifecycle
All (31)Filed (1)Violation (19)Special Inspection (11)
09/15/2026
Filed — Alteration
HEREWITH FILE ALTERATION IN ORDER TO DO AN INTERIOR RENOVATION & REPLACEMENT OF EXTERIOR FACADE TO AN EXISTING TWO STORY TWO FAMILY DWELLING WITH CELLAR & GARAGE AS PER C OF O # 300796592. TO ERECT INTERIOR PARTITIONS, TO DO PLUMBING WORK AND OBTAIN LOC.
B01460063-I1
09/15/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
09/15/2026
Special inspection requirement — Mechanical Systems
09/15/2026
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
09/15/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
09/15/2026
Special inspection requirement — Final
09/15/2026
Special inspection requirement — Energy Code Compliance Inspections
09/15/2026
Special inspection requirement — Structural Wood Frame
09/15/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
09/15/2026
Special inspection requirement — HVAC-R and service water heating system controls
09/15/2026
Special inspection requirement — Interior lighting power
09/15/2026
Special inspection requirement — HVAC-R and service water heating equipment
04/30/2002
Violation issued (ECB, closed)
Construction
08/30/2001
Violation issued (ECB, closed)
Construction
08/30/2001
Violation issued (ECB, closed)
Construction
01/07/1993
Violation issued (ECB, closed)
Construction
03/24/1992
Violation issued (ECB, closed)
Construction
12/09/1991
Violation issued (DOB, closed)
VPW*-VIOLATION UNSERVED ECB-WORK WITHOUT PERMIT-DISMISSED
08/30/1991
Violation issued (ECB, closed)
Construction
08/22/1990
Violation issued (DOB, closed)
VP*-VIOLATION UNSERVED ECB- DISMISSED
08/30/1989
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/31/1989
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/10/1989
Violation issued (ECB, closed)
Construction
03/20/1989
Violation issued (ECB, closed)
Construction
03/20/1989
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/01/1989
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/01/1989
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/11/1989
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/11/1989
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/20/1988
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/16/1988
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISEQISSUEDLINJO REALTY CO. LLC04/07/2003
BIS—ISSUEDLINFO REALTY CO. LLC04/07/2003
BISEQISSUEDLINJO REALTY CO. LLC03/05/2002
BIS—ISSUEDLINFO REALTY CO. LLC03/05/2002
BISPLISSUEDMIRABILE PLBG & HTG09/20/2001
BISOTISSUEDOWNER07/22/1993
1 project · most recent 09/15/2026
Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
09/15/2026——Ventilation Systems
Cooling
Mitsubishi Electric M4H36W06060615-B 40,000 BTU ×3
Heating
Mitsubishi Electric M4H36W06060615-B 40,000 BTU ×3
Ventilation
Mitsubishi Electric M4H36W06060615-B 40,000 BTU ×3
1 project · most recent 08/02/2026
FiledStatusContractorScope
08/02/2026Permit IssuedACCURATE ELEC'L CORP.3 meters, 3 new_meters
1 project · most recent 09/15/2026
Wood
FiledStatusContractorScope
09/15/2026——Wood
▾Special Inspection Requirements (DOB NOW) — 11
DateRequirementInspectorRole
09/15/2026Structural Stability – Alterations of existing buildings—special
09/15/2026Mechanical Systems—special
09/15/2026Exterior Insulation and Finish Systems (EIFS)—special
09/15/2026Fire-Resistant Penetrations and Joints—special
09/15/2026Final—progress
09/15/2026Energy Code Compliance Inspections—progress
09/15/2026Structural Wood Frame—progress
09/15/2026HVAC-R and service water piping design and insulation—energy_progress
09/15/2026HVAC-R and service water heating system controls—energy_progress
09/15/2026Interior lighting power—energy_progress
09/15/2026HVAC-R and service water heating equipment—energy_progress
▾Documents — 3 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
09/23/2026B01460063-I1Request digital key ↗
▸Seals & Professional Certifications1
▸DOB NOWDPL-1: Design Professional Seal & Signature1
09/23/2026B01460063-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
09/23/2026B01460063-I1Open ↗