← Back
BROOKLYN
2765 HOMECREST AVENUE
BROOKLYN · BIN 3429467
💬 Discuss this project
—Year Built
—Stories
—Building Class
—Zoning
—Gross Floor Area
—Units
Flood zone X500
Locations of Work
ArchitectureStructuralMechanicalFire ProtectionFire AlarmGeneral
Roof5p · 1 filing · 20 docs
Bulkhead4p · 1 filing · 20 docs
Floor 63p · 1 filing · 20 docs
Floor 52p · 1 filing · 20 docs
Floor 42p · 1 filing · 20 docs
Floor 33p · 1 filing · 20 docs
Floor 23p · 1 filing · 20 docs
Floor 15p · 2 filings · 20 docs
Cellar1p · 1 filing · 20 docs
Basement1p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
2761 HOMECREST LLC1703/22/2026
HAZEL BLUE BUILDER403/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
YAKER ENGINEERING, P.C.605/31/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BANJI ARCHITECT PC603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DOMOVOY LLCGeneral Contractor203/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
YAKER ENGINEERING, P.C.4892105/31/2023
Building Lifecycle
All (77)Filed (6)Permit Issued (1)Objection (40)Special Inspection (30)
08/11/2023
Objection resolved — Addressed
07/31/2023
Objection resolved — Addressed
07/31/2023
Special inspection requirement — HVAC-R and service water heating system controls
07/31/2023
Special inspection requirement — Shutoff dampers
07/31/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
07/31/2023
Special inspection requirement — HVAC-R and service water heating equipment
07/31/2023
Special inspection requirement — Maintenance information
07/28/2023
Special inspection requirement — HVAC-R and service water heating system controls
07/28/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
07/28/2023
Special inspection requirement — Maintenance information
07/28/2023
Special inspection requirement — HVAC-R and service water heating equipment
06/14/2023
Objection resolved — Addressed
06/14/2023
Objection resolved — Addressed
06/14/2023
Objection resolved — Addressed
06/07/2023
Objection raised — Energy
06/06/2023
Objection resolved — Addressed
06/05/2023
Objection raised — Energy
06/02/2023
Objection raised — Scope
06/01/2023
Objection raised — Other
06/01/2023
Objection raised — Inspections
06/01/2023
Objection raised — Structural
05/31/2023
Filed — New Building
Application is being filed for installation of mechanical system.
B08000518-S5
05/31/2023
Filed — New Building
Application is being filed for installation of mechanical system.
B08000518-S4
05/31/2023
Filed — New Building
Application is being filed for installation of mechanical system.
B08000518-S6
05/26/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
05/25/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Aleksandr Yaker
05/24/2023
Special inspection requirement — Sprinkler Systems
05/10/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
05/10/2023
Special inspection requirement — Energy Code Compliance Inspections
05/10/2023
Special inspection requirement — Heating Systems
05/10/2023
Special inspection requirement — Fire-Resistance Rated Construction
05/09/2023
Special inspection requirement — Final
05/09/2023
Special inspection requirement — Mechanical Systems
04/03/2023
Objection resolved — Addressed
04/03/2023
Objection resolved — Addressed
04/03/2023
Objection resolved — Addressed
04/03/2023
Objection resolved — Addressed
04/03/2023
Objection resolved — Addressed
03/14/2023
Objection resolved — Addressed
03/14/2023
Objection resolved — Addressed
03/14/2023
Objection resolved — Addressed
03/14/2023
Objection resolved — Addressed
03/14/2023
Objection resolved — Addressed
03/14/2023
Objection resolved — Addressed
03/09/2023
Objection raised — Structural
03/09/2023
Objection raised — Structural
03/09/2023
Objection raised — Structural
03/09/2023
Objection raised — Admin
03/09/2023
Objection raised — Scope
03/09/2023
Objection raised — Admin
03/09/2023
Objection raised — Other
03/09/2023
Objection raised — Energy
03/09/2023
Objection raised — Structural
03/09/2023
Objection raised — Scope
03/09/2023
Objection raised — Admin
03/08/2023
Filed — New Building
Application is being filed for installation of mechanical system.
B08000518-S3
03/06/2023
Special inspection requirement — Subgrade Inspections
03/06/2023
Special inspection requirement — Structural Steel - Welding
03/06/2023
Special inspection requirement — Structural Steel - Details
03/06/2023
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Latest 60 of 77 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FencePermit IssuedDOMOVOY LLC04/08/2022
BISEQISSUEDHUDSON MAINTENANCE CORP02/12/2010
BISEQISSUEDHUDSON MAINTENANCE CORP03/18/2009
BISEQISSUEDALKROM BUILDERS LTD06/19/2007
1 project · most recent 05/31/2023
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
05/31/2023——Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Daikin FXAQ18PVJU, FXAQ07PVJU 54,000 BTU · Vrf Indoor ×30
RXTQ36TAVJ9A 304,000 BTU · Vrf Outdoor ×19
FXMQ48PBVJU 408,000 BTU · Vrf Indoor ×10
RXTQ48TAVJUA 40,000 BTU · Vrf Outdoor ×10
FXAQ12PVJU, FXAQ07PVJU 42,000 BTU · Vrf Indoor ×8
FXMQ36PBVJU, FXMQ36PBVJU 178,000 BTU · Vrf Indoor ×3
RXTQ48TAVJUA, RXTQ36TAVJ9A 176,000 BTU · Vrf Outdoor ×3
Ventilation
Renewaire HE1XINH 700 CFM · Erv ×4
1 project · most recent 05/31/2023
Sprinkler System
FiledStatusContractorScope
05/31/2023——Sprinkler System
1 project · most recent 05/31/2023
Water/Sanitary
FiledStatusContractorScope
05/31/2023——Water/Sanitary
1 project · most recent 05/31/2023
Steel Concrete
FiledStatusContractorScope
05/31/2023——Steel, Concrete
▾Special Inspection Requirements (DOB NOW) — 50
DateRequirementInspectorRole
07/31/2023HVAC-R and service water heating system controls—energy_progress
07/31/2023Shutoff dampers—energy_progress
07/31/2023HVAC-R and service water piping design and insulation—energy_progress
07/31/2023HVAC-R and service water heating equipment—energy_progress
07/31/2023Maintenance information—energy_progress
07/28/2023HVAC-R and service water heating system controls—energy_progress
07/28/2023HVAC-R and service water piping design and insulation—energy_progress
07/28/2023Maintenance information—energy_progress
07/28/2023HVAC-R and service water heating equipment—energy_progress
05/26/2023Fire-Resistant Penetrations and Joints—special
05/25/2023Fire-Resistant Penetrations and JointsAleksandr Yakerspecial
05/24/2023Sprinkler Systems—special
05/10/2023Fire-Resistant Penetrations and Joints—special
05/10/2023Energy Code Compliance Inspections—progress
05/10/2023Heating Systems—special
05/10/2023Fire-Resistance Rated Construction—progress
05/09/2023Final—progress
05/09/2023Mechanical Systems—special
03/06/2023Subgrade Inspections—special
03/06/2023Structural Steel - Welding—special
03/06/2023Structural Steel - Details—special
03/06/2023Subsurface Investigations (Borings/Test Pits)—special
03/06/2023Deep Foundation Elements—special
03/06/2023Concrete - Cast-In-Place—special
03/06/2023Structural Cold-Formed Steel—special
Latest 25 of 50.
▾Documents — 28 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/31/2026B00682788-I1Request digital key ↗
08/15/2026B08000518-I1Request digital key ↗
08/15/2026B08000518-S4Request digital key ↗
Showing 3 of 6 on file for this type
▸Zoning, Tax Lot & Property Records3
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B08000518-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026B08000518-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/13/2026B08000518-I1Open ↗
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/28/2026B08000518-S3Open ↗
08/28/2026B08000518-I1Open ↗
08/28/2026B08000518-S5Open ↗
Showing 3 of 6 on file for this type
▸Trade Schedules & Equipment1
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)1
08/13/2026B08000518-I1Open ↗
▸Safety & Tenant Protection2
▸DOB NOWStreet Tree Checklist2
08/15/2026B08000518-I1Open ↗
08/14/2026B08000518-S3Open ↗
▸Inspections & Test Reports2
▸DOB NOWSOIL REPORT1
08/13/2026B08000518-S3Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026B08000518-S3Open ↗
▸Other Documents8
▸DOB NOWFlood Plan Emergency Temporary Flood Shields3
08/15/2026B08000518-I1Open ↗
08/15/2026B08000518-I1Open ↗
08/14/2026B08000518-S3Open ↗
▸DOB NOWSite Survey: Initial2
08/13/2026B08000518-I1Open ↗
08/13/2026B08000518-S3Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026B08000518-I1Open ↗
08/13/2026B08000518-S3Open ↗
▸DOB NOWProperty Ownership Certification1
08/15/2026B08000518-I1Open ↗