HPD01/11/2026§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL
HPD01/11/2026§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT CELLER AT BOILER ROOM
HPD01/11/2026§27-2045(B)(5) HMC, § 12-06, 12-10 RCNY POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN PRIVATE DWELLINGS THAT IS MISSING
HPD01/11/2026§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR THAT IS MISSING AT PUBLIC HALL, 1st STORY
HPD01/11/2026§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY
HPD01/11/2026§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL
HPD01/11/2026§27-2045(B)(5) HMC, § 12-01 RCNY POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAILBOX THAT IS MISSING AT PUBLIC HALL, 1st STORY
HPD01/11/2026§ 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE 2nd ROOM FROM NORTH LOCATED AT B-ROOM 616, 6th STORY, 2nd B-ROOM FROM NORTH AT EAST
HPD04/14/2025§ 27-2042 ADM CODE PROVIDE A MIRROR IN SELF-SERVICE ELEVATOR ARRANGED SO AS TO ENABLE A PERSON ENTERING, TO VIEW INSIDE OF ELEVATOR NUMBER 3P11933
HPD04/14/2025§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE HEATING AND AIR CONDITIONING UNIT IN THE 2nd ROOM FROM NORTH LOCATED AT B-ROOM 308, 3rd STORY, 4th B-ROOM FROM EAST AT SOUTH
HPD04/14/2025§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT B-ROOM 308, 3rd STORY, 4th B-ROOM FROM EAST AT SOUTH
ECB09/16/2025CLASS 1 CEASE USE ITEM: CONTROLLER F7 FUSE BYPASSED, ELIMINATING REQUIRED OVERCURRENT PROTECTION IN ELEVATOR CONTROL CIRCUIT. THIS CONSTITUTES A HAZARDOUS CONDITION PER ASME A17.1 SECTION 2.26 AND NYC BUILDINGNothing owed — awaiting certificate of correction
ECB05/22/20251) THERE IS OIL IN THE PIT. CLEAN THE PIT AND THE REPLACE THE OIL WITH CLEAN OIL. 2) PROVIDE FIRE BLOCKING FOR THE HOISTWAY AT THE POINT WHERE THE PIPE LINE COMES INTO THE HOISTWAY.Nothing owed — awaiting certificate of correction