← Back
Three families
28-31 36 STREET
QUEENS · BIN 4009235
💬 Discuss this project
1930Year Built
2Stories
C0Building Class
R5BZoning
1,900 sfGross Floor Area
3Units
0 Open Violations
Three families · 2,500 sf lot · 0.76 FAR built · Flood zone X
Locations of Work
Architecture
Permit Issued — active, not yet Signed-off
Floor 2Under Construction5p · 1 filing · 11 docs
Floor 1Under Construction5p · 1 filing · 11 docs
CellarUnder Construction6p · 1 filing · 11 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/14/2015$1.4M—Private party → Private party$713/sf building
07/29/2014$850K—Private party → Private party$447/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MAYERFELD ARCHITECTURE PLLC212/30/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
PDG BUILDING CONSULTANTS LLC LLC403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DESIGN 2 BUILD NEW YORK IGeneral Contractor507/08/2026
GIANNELLI, ANTHONYElectrical103/21/2026
M. BLAUSTEIN & SON, INCElectrical103/21/2026
PRASSAKOS, GEORGEElectrical103/21/2026
AP PLUMBING & HVAC LLCPlumbing106/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SHAHRISH SHUVO ENGINEERIN8524112/30/2024
Building Lifecycle
All (21)Filed (2)Permit Issued (4)Violation (3)Inspection (1)Objection (8)Special Inspection (3)
06/10/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
01/12/2026
Permit issued — General Construction
Q01107928-I1-GC
05/20/2025
Permit issued — Plumbing
Q01107928-S1-PL
04/24/2025
Objection resolved — Addressed
03/07/2025
Objection raised — Energy
02/26/2025
Objection resolved — Addressed
02/07/2025
Permit issued — General Construction
Q01107928-I1-GC
01/20/2025
Objection resolved — Addressed
01/15/2025
Objection resolved — Addressed
01/15/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Shahrish Shuvo
01/09/2025
Objection raised — Plumbing
01/09/2025
Objection raised — Structural
01/09/2025
Objection raised — Plumbing
12/30/2024
Filed — Alteration CO
Application filed to convert a two family Dwelling to a one family dwelling. As per plans filed.
Q01107928-S1
12/23/2024
Special inspection requirement — Energy Code Compliance Inspections
Shahrish Shuvo
12/23/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Shahrish Shuvo
12/19/2024
Permit issued — General Construction
Q01107928-I1-GC
09/25/2024
Filed — Alteration CO
Application filed to convert a two family Dwelling to a one family dwelling. As per plans filed.
Q01107928-I1
05/14/2015
Violation issued (ECB, closed)
Construction
10/10/2014
Violation issued (ECB, closed)
Construction
10/10/2014
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedDESIGN 2 BUILD NEW YORK I01/12/2026
DOB NOWPlumbingSigned-offCROSSFIELD PLBG.&HTG05/20/2025
DOB NOWGeneral ConstructionPermit IssuedDESIGN 2 BUILD NEW YORK I02/07/2025
DOB NOWGeneral ConstructionPermit IssuedDESIGN 2 BUILD NEW YORK I12/19/2024
BISMHISSUEDN/A04/23/2015
BISPLISSUEDVITELLO SEWER W.M H&P SER04/21/2015
1 project · most recent 12/30/2024
Gas Water/Sanitary
FiledStatusContractorScope
12/30/2024Signed-offCROSSFIELD PLBG.&HTGGas, Water/Sanitary
1 project · most recent 10/17/2025
General Wiring
FiledStatusContractorScope
10/17/2025Permit IssuedLENS ELECTRIC, INCGeneral Wiring
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
06/10/2026Pass-Final CND-Occupancy InspectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
01/15/2025Fire-Resistant Penetrations and JointsShahrish Shuvospecial
12/23/2024Energy Code Compliance InspectionsShahrish Shuvoprogress
12/23/2024HVAC-R and service water piping design and insulationShahrish Shuvoenergy_progress
▾Documents — 29 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/21/2026Q01107928-S1Request digital key ↗
08/21/2026Q01107928-I1Request digital key ↗
▸Applications & Permits4
▸BISWORK PERMIT APPLICATION2
04/30/2015421074465Open ↗
04/28/2015421074465Open ↗
▸BISNon-Directive 14 Construction Sign Off Including Sign Applications1
07/14/2015421074465Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
04/17/2015421074465Open ↗
▸Seals & Professional Certifications8
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
07/14/2015421074465Open ↗
04/17/2015421074465Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/26/2026Q01107928-S1Open ↗
08/26/2026Q01107928-S1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026Q01107928-I1Open ↗
08/13/2026Q01107928-S1Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
04/17/2015421074465Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/26/2026Q01107928-S1Open ↗
▸Trade Schedules & Equipment3
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
04/17/2015421074465Open ↗
▸BISPLUMBING - SUPPORTING DOCUMENTATION1
07/16/2015421074465Open ↗
▸BISSELF-CERT PLUMBING NOTICE1
07/16/2015421074465Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/13/2026Q01107928-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026Q01107928-S1Open ↗
08/13/2026Q01107928-I1Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
07/14/2015421074465Open ↗
04/17/2015421074465Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
07/14/2015421074465Open ↗
▸Approvals, Objections & Sign-offs2
▸BISLETTERS - SUPPORTING DOCUMENTATION1
07/16/2015421074465Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
07/14/2015421074465Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
07/14/2015421074465Open ↗
04/17/2015421074465Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
04/17/2015421074465Open ↗
▸Other Documents1
▸DOB NOWProperty Ownership Certification1
08/13/2026Q01107928-I1Open ↗