← Back
BuildNYC
Two stories - detached, small or mid-size
28 AMELIA COURT
STATEN ISLAND · BIN 5001895
💬 Discuss this project
1925Year Built
2.5Stories
A1Building Class
R2Zoning
2,126 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 5,280 sf lot · 0.4 FAR built · Flood zone X500
Locations of Work
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofHorizontal enlargement of existing one-family building1 filing · 20 docs
Floor 2Horizontal enlargement of existing one-family building2 filings · 20 docs
Floor 1Horizontal enlargement of existing one-family building2 filings · 20 docs
CellarPlumbing fixture installation for dwelling1 filing · 5 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
2436 E 2 ST203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Neville Engineering Group406/07/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Scarano Architect803/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SRA Planning & Expediting5677206/07/2022
Building Lifecycle
06/13/2022
Special inspection requirement — Concrete - Cast-In-Place
06/13/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
06/13/2022
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
BRIAN FLYNN
06/13/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
06/13/2022
Special inspection requirement — Final
40 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Nothing on file for this building.
1 project · most recent 01/19/2022
Gas Storm Water/Sanitary
FiledStatusContractorScope
01/19/2022——Gas, Storm, Water/Sanitary
1 project · most recent 06/07/2022
Concrete Wood
FiledStatusContractorScope
06/07/2022——Concrete, Wood
▾Special Inspection Requirements (DOB NOW) — 56
DateRequirementInspectorRole
06/13/2022Concrete - Cast-In-Place—special
06/13/2022Fire-Resistant Penetrations and Joints—special
06/13/2022Subsurface Investigations (Borings/Test Pits)BRIAN FLYNNspecial
06/13/2022Structural Stability – Alterations of existing buildings—special
06/13/2022Final—progress
06/13/2022Energy Code Compliance Inspections—progress
06/13/2022Structural Wood Frame—progress
06/13/2022Footing and Foundation—progress
06/13/2022Lighting controls—energy_progress
06/13/2022Protection of exposed foundation insulation—energy_progress
06/13/2022Interior lighting power—energy_progress
06/13/2022Lighting in dwelling units—energy_progress
06/13/2022Insulation placement and R values—energy_progress
06/13/2022Fenestration air leakage—energy_progress
06/13/2022Air barrier - visual inspection—energy_progress
06/13/2022Fenestration and door U-factor and product ratings—energy_progress
06/13/2022Fenestration areas—energy_progress
06/13/2022Exterior lighting power—energy_progress
05/26/2022FinalWILLIAM MONTAGUEprogress
05/26/2022Concrete - Cast-In-PlaceWILLIAM MONTAGUEspecial
05/26/2022Fire-Resistant Penetrations and JointsWILLIAM MONTAGUEspecial
05/26/2022Structural Stability – Alterations of existing buildingsWILLIAM MONTAGUEspecial
05/26/2022Subsurface Investigations (Borings/Test Pits)BRIAN FLYNNspecial
05/26/2022Energy Code Compliance InspectionsWILLIAM MONTAGUEprogress
05/26/2022Footing and FoundationWILLIAM MONTAGUEprogress
Latest 25 of 56.
54 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account