| Owner | Filings | Most Recent |
|---|---|---|
| RIVERSIDE DEVELOPERS | 47 | 09/07/2026 |
| OWNERS REP | 7 | 08/05/2026 |
| RIVERSIDE DEVELOPERS USA | 1 | 03/22/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| DANIEL CONDATORE, RA | 11 | 04/23/2026 |
| TITAN ENGINEERS PC | 10 | 09/05/2025 |
| PAUL PERDEK, PROF. ENG. PLLC | 2 | 08/05/2025 |
| REVAP CONSULTING ENGINEERS LLC | 1 | 03/23/2022 |
| Representative | Filings | Most Recent |
|---|---|---|
| BAC Developers Group | 20 | 03/21/2026 |
| ZV Drafting | 1 | 03/21/2026 |
| AE DESIGN SOLUTION | 4 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| RIVERSIDE DEVELOPERS USA | General Contractor | 18 | 08/11/2026 |
| CORE SCAFFOLD SYSTEMS INC. | General Contractor | 4 | 08/05/2026 |
| MMI PLUMBING & HEATING INC. | Plumbing | 2 | 07/22/2026 |
| TRISTATE FIRE SPRINK INC | Fire Protection | 2 | 09/07/2026 |
| HMF VENTURES LLC | General Contractor | 1 | 04/09/2026 |
| CITY WIDE BUILDERS GRP IN | General Contractor | 1 | 04/09/2026 |
| B&B MECH PLBG & HTG LLC | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| TECNICO SPECIAL INSPECTIO | 5939 | 17 | 04/23/2026 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Sprinklers | Permit Issued | TRISTATE FIRE SPRINK INC | 09/01/2026 |
| DOB NOW | General Construction | Permit Issued | RIVERSIDE DEVELOPERS USA | 08/10/2026 |
| DOB NOW | Structural | Signed-off | RIVERSIDE DEVELOPERS USA | 08/06/2026 |
| DOB NOW | Supported Scaffold | Permit Issued | CORE SCAFFOLD SYSTEMS INC. | 08/04/2026 |
| DOB NOW | Sidewalk Shed | Permit Issued | CORE SCAFFOLD SYSTEMS INC. | 08/03/2026 |
| DOB NOW | Construction Fence | Permit Issued | RIVERSIDE DEVELOPERS USA | 07/27/2026 |
| DOB NOW | Plumbing | Permit Issued | MMI PLUMBING & HEATING INC. | 07/21/2026 |
| DOB NOW | Plumbing | Permit Issued | MMI PLUMBING & HEATING INC. | 06/01/2026 |
| DOB NOW | Mechanical Systems | Permit Issued | RIVERSIDE DEVELOPERS USA | 05/15/2026 |
| DOB NOW | General Construction | Permit Issued | RIVERSIDE DEVELOPERS USA | 03/04/2026 |
| DOB NOW | Support of Excavation | Signed-off | RIVERSIDE DEVELOPERS USA | 11/19/2025 |
| DOB NOW | Foundation | Signed-off | RIVERSIDE DEVELOPERS USA | 11/19/2025 |
| DOB NOW | Earth Work | Permit Issued | RIVERSIDE DEVELOPERS USA | 11/19/2025 |
| DOB NOW | General Construction | Permit Issued | RIVERSIDE DEVELOPERS USA | 10/28/2025 |
| DOB NOW | Support of Excavation | Signed-off | RIVERSIDE DEVELOPERS USA | 09/11/2025 |
| DOB NOW | Foundation | Signed-off | RIVERSIDE DEVELOPERS USA | 09/10/2025 |
| DOB NOW | Sprinklers | Permit Issued | TRISTATE FIRE SPRINK INC | 09/04/2025 |
| DOB NOW | Structural | Signed-off | RIVERSIDE DEVELOPERS USA | 08/19/2025 |
| DOB NOW | Supported Scaffold | Permit Issued | CORE SCAFFOLD SYSTEMS INC | 08/05/2025 |
| DOB NOW | Sidewalk Shed | Permit Issued | CORE SCAFFOLD SYSTEMS INC | 08/05/2025 |
| DOB NOW | Construction Fence | Permit Issued | RIVERSIDE DEVELOPERS USA | 07/28/2025 |
| DOB NOW | Construction Fence | Permit Issued | RIVERSIDE DEVELOPERS USA | 05/14/2025 |
| DOB NOW | Plumbing | Permit Issued | TARGET PIPING NY LLC | 11/14/2024 |
| DOB NOW | Foundation | Permit Issued | RIVERSIDE DEVELOPERS USA | 10/10/2024 |
| DOB NOW | Support of Excavation | Signed-off | RIVERSIDE DEVELOPERS USA | 09/10/2024 |
| DOB NOW | Foundation | Signed-off | RIVERSIDE DEVELOPERS USA | 09/10/2024 |
| DOB NOW | Construction Fence | Permit Issued | CITY WIDE BUILDERS GRP IN | 05/23/2024 |
| DOB NOW | Foundation | Permit Issued | HMF VENTURES | 06/07/2022 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 04/23/2026 | Permit Issued | RIVERSIDE DEVELOPERS USA | Air Conditioning Systems, Heating Systems, Ventilation Systems | Cooling Mitsubishi Electric MXZ-SM48NAM2-U1 48,000 BTU · Heat Pump Outdoor ×5 MXZ-SM36NAM2-U1 36,000 BTU · Heat Pump Outdoor ×4 MXZ-SM60NAM2-U1 60,000 BTU · Heat Pump Outdoor ×3 PUZ-A12NKA7 12,000 BTU · Heat Pump Outdoor ×2 Heating Mitsubishi Electric MXZ-SM48NAM2-U1 50,000 BTU · Heat Pump Outdoor ×5 MXZ-SM60NAM2-U1 660,000 BTU · Heat Pump Outdoor ×3 PUZ-A12NKA7 14,000 BTU · Heat Pump Outdoor ×2 MXZ-SM36NAM2-U1 41,000 BTU · Heat Pump Outdoor ×1 Ventilation Greenheck SP-B90 50 CFM · Exhaust Fan ×21 SP-B110 100 CFM · Exhaust Fan ×8 CUE-100-VG 800 CFM · Exhaust Fan ×1 G-120-VG 1,050 CFM · Exhaust Fan ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 04/23/2026 | Permit Issued | MMI PLUMBING & HEATING IN | Gas, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 12/18/2025 | Permit Issued | HIGH STANDARD ELECTRIC | General Wiring |
| 08/27/2025 | Permit Issued | HIGH STANDARD ELECTRIC | — |
| 08/07/2025 | Permit Issued | SOLAS ELECTRICAL CORP | — |
| 08/02/2025 | Permit Issued | DENALI ELECTRIC CORP | — |
| 07/08/2025 | Permit Issued | HIGH STANDARD ELECTRIC | 7 meters, 7 new_meters |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 04/23/2026 | Permit Issued | TRISTATE FIRE SPRINK INC | Concrete, Masonry |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/05/2025 | Permit Issued | CORE SCAFFOLD SYSTEMS INC | Sidewalk Shed |
| 08/05/2025 | Permit Issued | CORE SCAFFOLD SYSTEMS INC | Scaffold |
| 03/23/2022 | Permit Issued | RIVERSIDE DEVELOPERS USA | Fence |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 04/30/2026 | Wall Panels, Curtain Walls, and Veneers | Jose Lockhart | special |
| 04/30/2026 | Fenestration air leakage | Jose Lockhart | energy_progress |
| 04/30/2026 | Air barrier — testing | Jose Lockhart | energy_progress |
| 04/30/2026 | Air barrier - visual inspection | Jose Lockhart | energy_progress |
| 04/30/2026 | Metering | Jose Lockhart | energy_progress |
| 04/30/2026 | Vestibules | Jose Lockhart | energy_progress |
| 04/30/2026 | Fireplaces | Jose Lockhart | energy_progress |
| 04/30/2026 | Interior lighting power | Jose Lockhart | energy_progress |
| 04/30/2026 | Fenestration areas | Jose Lockhart | energy_progress |
| 04/30/2026 | Fenestration and door U-factor and product ratings | Jose Lockhart | energy_progress |
| 04/30/2026 | Air barrier continuity plan testing | Jose Lockhart | energy_progress |
| 04/30/2026 | Exterior lighting power | Jose Lockhart | energy_progress |
| 04/30/2026 | Lighting in dwelling units | Jose Lockhart | energy_progress |
| 04/30/2026 | Electrical motors and elevators | Jose Lockhart | energy_progress |
| 04/30/2026 | Lighting controls | Jose Lockhart | energy_progress |
| 04/30/2026 | Maintenance information | Jose Lockhart | energy_progress |
| 04/30/2026 | Insulation placement and R values | Jose Lockhart | energy_progress |
| 04/30/2026 | Protection of exposed foundation insulation | Jose Lockhart | energy_progress |
| 04/30/2026 | Energy Code Compliance Inspections | Jose Lockhart | progress |
| 04/30/2026 | Fire-Resistance Rated Construction | Jose Lockhart | progress |
| 04/30/2026 | Post-installed Anchors | Jose Lockhart | special |
| 04/30/2026 | Exterior Insulation and Finish Systems (EIFS) | Jose Lockhart | special |
| 04/30/2026 | Fire-Resistant Penetrations and Joints | Jose Lockhart | special |
| 04/30/2026 | Masonry | Jose Lockhart | special |
| 04/30/2026 | Mastic and Intumescent Fire-resistant Coatings | Jose Lockhart | special |