DOB11/14/2025Violation issued-failure to file 2024 external low pressure inspection2 identical filings
DOB09/23/2024Violation issued-failure to file 2023 external low pressure inspection2 identical filings
DOB03/05/2024Failure to maintain building in code-compliant manner: facade condition in a state of disrepair observed vertical stress cracks running from 1 st floor to roof at corner of exposure #1, stucco missing exposing bricks in various area.
ECB02/20/2020At time of inspection, at apartment #31 at third floor of premises, 100 square feet of missing fire stopping at drywall ceiling, compromising the fire rating of said ceiling at premises, an occupied loft/interi$312 due
HPD01/02/2018§ 27-2005 ADM code properly repair the broken or defective os&y valve near east wall at cellar
HPD01/02/2018§ 27-2005, 2050 hmc: provide an adequate supply of water for the wet sprinkler and/or standpipe system at all apartments, public halls throughout entire building
HPD01/02/2018§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE SPRINKLER SUPPLY PIPE AT CEILING NEAR WEST WALL , 1st STORY
HPD07/30/2007SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DISCONNECTED RADIATOR, AT PUBLIC HALL, 4th STORY
HPD07/30/2007SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. LOCATED AT APT 32, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST
HPD07/30/2007SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WINDOW GLASS PANE, AT PUBLIC HALL STAIRS, 3rd STORY
HPD07/30/2007Section 27-2005 ADM code properly repair with similar material the broken or defective fire retarding ceilings and walls, all stories, at public hall stairs
HPD07/30/2007Section 27-2013 ADM code paint with light colored paint to the satisfaction of this department , the ceilings and walls, all stories, at public hall stairs
HPD07/30/2007SECTION 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES .. IN THE ENTIRE APARTMENT LOCATED AT APT 32, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST
ECB02/22/2024Failure to maintain building in code-compliant manner. At time of inspection, observed facade condition in a state of disrepair. Observed vertical stress cracks running from 1ST to roof at the corner of EXP1, sNothing owed — awaiting certificate of correction
ECB12/07/2017Gas being supplied to building without inspection and certification by DOB. At the time of inspection at the above address on the above date i observed gas piping supplying boiler for heat and hot water withoutNothing owed — awaiting certificate of correction
ECB12/07/2017Failure to have new or altered plumbing system tested. At the time of inspection at the above address on the above date. I observed on 2ND floor a wall hang boiler on hallway without any testing performed boileNothing owed — awaiting certificate of correction
ECB12/04/2013Failure to maintain bldg minimum head roon in required stairway is 83 inches as required by C26-275.0 of 1938 bldg code. (at time of inspection head room is 72 inches) remedy: maintain bldg.Nothing owed — awaiting certificate of correction
ECB12/04/2013Failure to maintain bldg stairway from 4TH fl to the roof is not enclosed & partially obstructed by household items violating C26-282.0 & C26-292 (6.4.11) K3 of 1938 bldg code. Remedy: maintain bldg.Nothing owed — awaiting certificate of correction
ECB12/04/2013Failure to maintain bldg egress door to the roof doesn't have requiredhardware door secured w/a device that is not readily operable as requ ired by C26-285 of 1938 bldg code. Remedy: maintain bldg.Nothing owed — awaiting certificate of correction
ECB12/04/2013Failure to maintain bldg 1)no fire stopping provided around multiple pipe penetration between floors. 2)fire escape ladder in ally way missing treads at the bottom 3)broken skylight at roof. 4)1ST fl rear roofNothing owed — awaiting certificate of correction
ECB02/12/2008Failure to maintain bldg. Defect is: flue pipe detached from bldg exterior side wall adjoin to parking lot. Flue pipe loose & hanging at 4 flr side of bldg over parking lot at 270 nevins st. Window glass brokenNothing owed — awaiting certificate of correction
ECB10/17/2005Failure to maintain building note: rusty and loose metal sheeting at bulkhead incloser wall, along with vertical crack in east interior wallat 4TH story. (2) vertical cracks at east facade at various locationNothing owed — awaiting certificate of correction
Likely answered · the city's own records show a filing, but DOB's feed still lists these as active
DOB09/15/2017Violation issued to elevator-failure to file category 1 2016 inspection/testThe owner has filed since: Category 1 elevator reports are on file for later years (latest 2018). This one is not shown as answered
DOB11/14/2016Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tstThe owner has filed since: Category 1 elevator reports are on file for later years (latest 2018). This one is not shown as answered
Old · issued 3+ years ago and still listed by DOB; nothing on the city's records either way
DOB08/02/2023Failure to file benchmarking report of energy use as per ad. Code sec. 28-309.4Issued 2023; DOB's record still lists it as active
DOB06/30/2023Violation issued-failure to file 2020 external low pressure inspectionIssued 2023; DOB's record still lists it as active2 identical filings
DOB06/30/2023Violation issued-failure to file 2021 external low pressure inspectionIssued 2023; DOB's record still lists it as active2 identical filings
DOB06/20/2023Violation issued-failure to file 2019 external low pressure inspectionIssued 2023; DOB's record still lists it as active2 identical filings
DOB06/20/2023Violation issued-failure to file 2018 external low pressure inspectionIssued 2023; DOB's record still lists it as active2 identical filings
DOB05/02/2023Failure to file benchmarking report of energy use as per ad. Code sec. 28-309.4Issued 2023; DOB's record still lists it as active
DOB04/25/2023Violation issued-failure to file 2022 external low pressure inspectionIssued 2023; DOB's record still lists it as active2 identical filings
DOB02/02/2022Failure to file benchmarking report of energy use as per ad. Code sec. 28-309.4Issued 2022; DOB's record still lists it as active
DOB12/01/2021Failure to display energy efficiency score and energy efficiency grade as per Admin. Code sec. 28-309.12.3Issued 2021; DOB's record still lists it as active
DOB11/02/2021Failure to file benchmarking report of energy use as per ad. Code sec. 28-309.4Issued 2021; DOB's record still lists it as active
DOB08/02/2021Failure to file benchmarking report of energy use as per ad. Code sec. 28-309.4Issued 2021; DOB's record still lists it as active
DOB06/02/2021Failure to file benchmarking report of energy use as per ad. Code sec. 28-309.4Issued 2021; DOB's record still lists it as active
DOB11/08/2019Violation issued for failure to file annual boiler 2017 inspection reportIssued 2019; DOB's record still lists it as active2 identical filings
DOB05/20/2019Failure to perform category 5 inspectionIssued 2019; DOB's record still lists it as active
DOB04/06/2018Violation issued for failure to file annual boiler 2016 inspection reportIssued 2018; DOB's record still lists it as active2 identical filings
DOB03/07/2018Failure to certify correction on immediately hazardous (class 1) ECB violationIssued 2018; DOB's record still lists it as active2 identical filings
DOB02/24/2017Violation issued for failure to file annual boiler 2015 inspection reportIssued 2017; DOB's record still lists it as active2 identical filings