| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 03/10/2026 | Permit Issued | ARNELL CONSTRUCTION CORP | Air Conditioning Systems, Refrigeration Systems, Ventilation Systems | Ventilation New York Blower Compact Pressure Blower 100506 300 CFM · Exhaust Fan ×1 Compact Pressure Blower Model 100506 300 CFM · Exhaust Fan ×1 Pennbarry Z12GP 400 CFM · Exhaust Fan ×2 DX12B 1,355 CFM · Exhaust Fan ×1 FX12BH 1,600 CFM · Exhaust Fan ×1 FX24BH 3,850 CFM · Exhaust Fan ×1 MXI - 222 A9 9,000 CFM · Exhaust Fan ×1 SX100BC 600 CFM · Exhaust Fan ×1 SX115VCGP 500 CFM · Exhaust Fan ×1 SX120BC 2,150 CFM · Exhaust Fan ×1 TXD-030A4 9,000 CFM · Exhaust Fan ×1 Z8GP 80 CFM · Exhaust Fan ×1 Annexair ERP-E-07-EW03-H-H-C-SS 6,500 CFM · Rooftop Unit ×1 ERP-E-09-EW04-H-H-C-SW-SS 10,000 CFM · Rooftop Unit ×1 ERP-E-20-EW07-H-H-C-SW-SS 21,350 CFM · Rooftop Unit ×1 MAU-I-04-H-C-SS 3,750 CFM · Ahu ×1 Cooling Lg Indoor Unit: LSN363HLV3 33,000 BTU · Packaged Unit ×3 LSU363HLV3 33,000 BTU · Heat Pump Outdoor ×3 Indoor Unit: ARNU303SVA4 30,000 BTU · Vrf Indoor ×2 Indoor Unit: LSN243HLV3 22,000 BTU · Packaged Unit ×2 LSU243HLV3 22,000 BTU · Heat Pump Outdoor ×2 ARUN060GSS4 60,000 BTU · Vrf Outdoor ×1 Indoor Unit: LSN120HSV5 12,000 BTU · Packaged Unit ×1 LSU120HSV5 12,000 BTU · Heat Pump Outdoor ×1 Refrigeration Arctic Chill Overall Model # AXM030
Typical Module Model No.: AXMA0304XXCAAXXXXGXX1TXXA1AANX 143 tons · Chiller ×5 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/30/2025 | Complete | TRU-VAL ELECTRIC CORP. | General Wiring, Lighting |
| 08/11/2023 | Complete | RAIDEN ELECTRIC LLC | — |
| Owner | Filings | Most Recent |
|---|---|---|
| NYC SCHOOL CONSTRUCTION AUTHORITY | 87 | 07/31/2026 |
| ARNELL CONSTRUCTION | 1 | 03/22/2026 |
| NYCSCA | 1 | 03/22/2026 |
| SCHOOL CONSTRUCTION AUTHORITY | 1 | 03/21/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| STANTEC ARCHITECTURE INC. | 29 | 03/10/2026 |
| LEVIN ENGINEERING PLLC | 4 | 09/17/2024 |
| 360 ENGINEERING P.C. | 4 | 03/22/2024 |
| DSENY ENGINEERING SERVICES, PC | 1 | 07/13/2023 |
| ROYAL CONST. PROFES. ENG. SER. P.C. | 1 | 02/10/2023 |
| MACRO ENTERPRISES, LTD | 1 | 01/05/2023 |
| AKRF, INC. | 1 | 04/29/2022 |
| Representative | Filings | Most Recent |
|---|---|---|
| SOL BUILDING CONSULTING SERVICES | 4 | 03/21/2026 |
| JMV ASSOCIATES | 6 | 03/21/2026 |
| STANTEC ARCHITECTURE | 17 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| ARNELL CONSTRUCTION CORP | General Contractor | 46 | 07/31/2026 |
| EAGLE 1 MECHANICAL, INC | Plumbing | 10 | 07/08/2026 |
| A & F FIRE PROTECTION CO | Fire Protection | 6 | 07/08/2026 |
| PJP INSTALLERS INC | General Contractor | 6 | 07/08/2026 |
| RAIDEN ELECTRIC, LLC | Electrical | 1 | 03/22/2026 |
| TRU-VAL ELECTRIC CORP. | Electrical | 1 | 03/22/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| MUNICIPAL TESTING LABORAT | 230 | 32 | 03/10/2026 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | General Construction | Permit Issued | ARNELL CONSTRUCTION CORP | 07/30/2026 |
| DOB NOW | Plumbing | Permit Issued | EAGLE 1 MECHANICAL, INC | 04/22/2026 |
| DOB NOW | Plumbing | Permit Issued | EAGLE 1 MECHANICAL, INC | 04/06/2026 |
| DOB NOW | Structural | Signed-off | ARNELL CONSTRUCTION CORP | 07/07/2025 |
| DOB NOW | Standpipe | Signed-off | ADVANCED AUTO SPR.CO.,INC | 07/03/2025 |
| DOB NOW | General Construction | Signed-off | ARNELL CONSTRUCTION CORP | 07/03/2025 |
| DOB NOW | Mechanical Systems | Signed-off | ARNELL CONSTRUCTION CORP | 07/03/2025 |
| DOB NOW | Sprinklers | Signed-off | ADVANCED AUTO SPR.CO.,INC | 07/03/2025 |
| DOB NOW | Plumbing | Permit Issued | EAGLE 1 MECHANICAL, INC | 04/23/2025 |
| DOB NOW | Plumbing | Permit Issued | EAGLE 1 MECHANICAL, INC | 04/08/2025 |
| DOB NOW | General Construction | Permit Issued | ARNELL CONSTRUCTION CORP | 03/26/2025 |
| DOB NOW | General Construction | Permit Issued | ARNELL CONSTRUCTION CORP | 12/20/2024 |
| DOB NOW | Earth Work | Signed-off | ARNELL CONSTRUCTION CORP | 11/20/2024 |
| DOB NOW | Mechanical Systems | Signed-off | ARNELL CONSTRUCTION CORP | 11/20/2024 |
| DOB NOW | Boiler Equipment | Signed-off | EAGLE 1 MECHANICAL, INC | 08/26/2024 |
| DOB NOW | Sprinklers | Signed-off | ADVANCED AUTO SPR.CO.,INC | 08/02/2024 |
| DOB NOW | Sprinklers | Signed-off | ADVANCED AUTO SPR.CO.,INC | 08/02/2024 |
| DOB NOW | Protection and Mechanical Methods | Signed-off | PJP INSTALLERS INC | 07/25/2024 |
| DOB NOW | Plumbing | Permit Issued | EAGLE 1 MECHANICAL, INC | 04/22/2024 |
| DOB NOW | Plumbing | Permit Issued | EAGLE 1 MECHANICAL, INC | 04/09/2024 |
| DOB NOW | General Construction | Permit Issued | ARNELL CONSTRUCTION CORP | 04/01/2024 |
| DOB NOW | General Construction | Signed-off | ARNELL CONSTRUCTION CORP | 04/01/2024 |
| DOB NOW | Earth Work | Signed-off | ARNELL CONSTRUCTION CORP | 04/01/2024 |
| DOB NOW | General Construction | Permit Issued | ARNELL CONSTRUCTION CORP | 12/29/2023 |
| DOB NOW | Earth Work | Signed-off | ARNELL CONSTRUCTION CORP | 12/29/2023 |
| DOB NOW | General Construction | Signed-off | ARNELL CONSTRUCTION CORP | 12/29/2023 |
| DOB NOW | Support of Excavation | Signed-off | ARNELL CONSTRUCTION CORP | 12/29/2023 |
| DOB NOW | Support of Excavation | Signed-off | ARNELL CONSTRUCTION CORP | 12/29/2023 |
| DOB NOW | Structural | Signed-off | ARNELL CONSTRUCTION CORP | 12/29/2023 |
| DOB NOW | Construction Fence | Signed-off | ARNELL CONSTRUCTION CORP | 12/29/2023 |
| DOB NOW | Mechanical Systems | Signed-off | ARNELL CONSTRUCTION CORP | 12/29/2023 |
| DOB NOW | Foundation | Signed-off | ARNELL CONSTRUCTION CORP | 12/29/2023 |
| DOB NOW | General Construction | Permit Issued | ARNELL CONSTRUCTION CORP | 11/29/2023 |
| DOB NOW | General Construction | Signed-off | ARNELL CONSTRUCTION CORP | 11/13/2023 |
| DOB NOW | Boiler Equipment | Signed-off | EAGLE 1 MECHANICAL, INC | 10/24/2023 |
| DOB NOW | Mechanical Systems | Signed-off | ARNELL CONSTRUCTION CORP | 10/24/2023 |
| DOB NOW | Mechanical Systems | Signed-off | ARNELL CONSTRUCTION CORP | 10/18/2023 |
| DOB NOW | General Construction | Permit Issued | ARNELL CONSTRUCTION CORP | 10/18/2023 |
| DOB NOW | Mechanical Systems | Signed-off | ARNELL CONSTRUCTION CORP | 10/18/2023 |
| DOB NOW | Support of Excavation | Signed-off | ARNELL CONSTRUCTION CORP | 10/18/2023 |
| Date | Type | Result | Report |
|---|---|---|---|
| 07/15/2026 | Fail-Final PL - Up to 3 Requested Floors | Fail | View ↗ |
| 06/22/2026 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 05/01/2026 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 04/28/2026 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 04/23/2026 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 11/17/2025 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 08/28/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 07/16/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 03/21/2025 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 02/26/2025 | Pass-Final SD - Up to 9 Requested Floors | Pass | View ↗ |
| 02/26/2025 | Pass-Final SP - Up to 9 Requested Floors | Pass | View ↗ |
| 02/14/2025 | Pass-Final PL - Underground | Pass | View ↗ |
| 02/14/2025 | Pass-Final PL - Up to 9 Requested Floors | Pass | View ↗ |
| 02/05/2025 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 02/05/2025 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 02/05/2025 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 02/05/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 02/05/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 11/22/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 10/23/2024 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 10/11/2024 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 10/11/2024 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 10/11/2024 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 10/11/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 10/11/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 03/11/2026 | Concrete - Precast | CLOUD LEE | special |
| 03/11/2026 | Wall Panels, Curtain Walls, and Veneers | CLOUD LEE | special |
| 03/11/2026 | Energy Code Compliance Inspections | CLOUD LEE | progress |
| 03/11/2026 | Fire-Resistance Rated Construction | CLOUD LEE | progress |
| 03/11/2026 | Protection of exposed foundation insulation | CLOUD LEE | energy_progress |
| 03/11/2026 | Air barrier continuity plan testing | CLOUD LEE | energy_progress |
| 03/11/2026 | Air barrier - visual inspection | CLOUD LEE | energy_progress |
| 03/11/2026 | Fenestration air leakage | CLOUD LEE | energy_progress |
| 03/11/2026 | Vestibules | CLOUD LEE | energy_progress |
| 03/11/2026 | Maintenance information | CLOUD LEE | energy_progress |
| 03/11/2026 | Insulation placement and R values | CLOUD LEE | energy_progress |
| 03/11/2026 | Post-installed Anchors | CLOUD LEE | special |
| 03/11/2026 | Sprayed fire-resistant materials | CLOUD LEE | special |
| 03/11/2026 | Concrete - Cast-In-Place | CLOUD LEE | special |
| 03/11/2026 | Air barrier — testing | CLOUD LEE | energy_progress |
| 03/11/2026 | Fenestration areas | CLOUD LEE | energy_progress |
| 03/11/2026 | Fenestration and door U-factor and product ratings | CLOUD LEE | energy_progress |
| 03/11/2026 | Fire-Resistant Penetrations and Joints | CLOUD LEE | special |
| 03/09/2026 | Vestibules | CLOUD LEE | energy_progress |
| 03/09/2026 | Protection of exposed foundation insulation | CLOUD LEE | energy_progress |
| 03/09/2026 | Maintenance information | CLOUD LEE | energy_progress |
| 03/09/2026 | Air barrier - visual inspection | CLOUD LEE | energy_progress |
| 03/09/2026 | Air barrier — testing | CLOUD LEE | energy_progress |
| 03/09/2026 | Air barrier continuity plan testing | CLOUD LEE | energy_progress |
| 03/09/2026 | Fenestration air leakage | CLOUD LEE | energy_progress |