← Back
Railroad, private ownership
281 11 AVENUE
MANHATTAN · BIN 1080275
💬 Discuss this project
0Year Built
—Stories
U6Building Class
M2-3Zoning
0 sfGross Floor Area
0Units
1 Open Violation ▸
Railroad, private ownership · 151,974 sf lot · 0 FAR built · Flood zone X500
Locations of Work
ArchitectureMechanical
Permit Issued — active, not yet Signed-off
Floor 2Under Construction70p · 1 filing · 20 docs
Floor 1
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
CON EDISON CO3009/13/2026
CON EDISON CO OF NY1303/22/2026
CONSOLIDATED EDISON CO2203/22/2026
CONSOLIDATED EDISON CO. OF NY1103/21/2026
CONSOLIDATED EDISON OF NEW YORK103/21/2026
CONSOLIDATED EDISON COMPANY NEW203/21/2026
CON EDISON CO OF N Y103/21/2026
CON ED CO203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LIRO ENGINEERS, INC.107/01/2026
LIRO-HILL206/30/2026
LIRO ARCHITECTS + PLANNERS, P.C.106/30/2026
THEODORE YEN108/26/2025
S.M. BERGER ARCHITECTURE PC111/06/2023
SIMPSON GUMPERTZ & HEGER309/26/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
FRIEDMAN ASSOCIATES II203/21/2026
JAM CONSULTANTS, INC.203/21/2026
BURNHAM NATIONWIDE INC303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JCC CONSTRUCTION CORPPlumbing403/22/2026
ACME INDUSTRIAL INCGeneral Contractor307/08/2026
ONSITE CONSTRUCTION ENTERPRISESGeneral Contractor307/08/2026
ON-TRAC CONSTRUCTION ASSOGeneral Contractor208/05/2026
MICHAEL GUNZERElectrical103/21/2026
PHILIP DEGALTINIElectrical103/21/2026
HEMNAUTH, SUDESHElectrical103/21/2026
D'ONOFRIO GENERAL CONTRACTORSGeneral Contractor103/21/2026
WALTON, MARCElectrical103/21/2026
HIRAM TIRADOElectrical103/21/2026
HUDSON SCENIC STUDIOElectrical103/21/2026
IVAN DUBBSElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
TECTONIC ENGINEERING CONS106707/01/2026
CATALPA SPECIAL INSPECTIO2004111/06/2023
Building Lifecycle
All (63)Filed (9)Permit Issued (7)Signed Off (2)Violation (15)Special Inspection (30)
10/10/2026
Violation issued (ECB, closed)
Boilers
08/04/2026
Permit issued — Mechanical Systems
M01342629-I1-MS
08/04/2026
Permit issued — General Construction
M01342629-S1-GC
07/01/2026
Filed — Alteration
Removal of existing gas-fired rooftop units, split systems, exhaust fans, indoor gas fired unit heaters, and gas fired boiler and domestic water heater and associated gas piping. Installation of new packaged air source heat pump rooftop systems, dedicated
M01342629-S3
06/30/2026
Filed — Alteration
Removal of existing gas-fired rooftop units, split systems, exhaust fans, indoor gas fired unit heaters, and gas fired boiler and domestic water heater and associated gas piping. Installation of new packaged air source heat pump rooftop systems, dedicated
M01342629-I1
06/30/2026
Filed — Alteration
Removal of existing gas-fired rooftop units, split systems, exhaust fans, indoor gas fired unit heaters, and gas fired boiler and domestic water heater and associated gas piping. Installation of new packaged air source heat pump rooftop systems, dedicated
M01342629-S1
06/30/2026
Filed — Alteration
Removal of existing gas-fired rooftop units, split systems, exhaust fans, indoor gas fired unit heaters, and gas fired boiler and domestic water heater and associated gas piping. Installation of new packaged air source heat pump rooftop systems, dedicated
M01342629-S2
06/17/2026
Special inspection requirement — Fenestration air leakage
GEORGE GHEBRYAL
06/17/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
GEORGE GHEBRYAL
06/17/2026
Special inspection requirement — Fenestration areas
GEORGE GHEBRYAL
06/12/2026
Special inspection requirement — Energy Code Compliance Inspections
GEORGE GHEBRYAL
06/05/2026
Special inspection requirement — Concrete - Cast-In-Place
GEORGE GHEBRYAL
06/05/2026
Special inspection requirement — Structural Steel - High Strength Bolting
GEORGE GHEBRYAL
05/29/2026
Special inspection requirement — Structural Steel - Details
GEORGE GHEBRYAL
05/29/2026
Special inspection requirement — Structural Steel - Welding
GEORGE GHEBRYAL
05/27/2026
Special inspection requirement — Energy Code Compliance Inspections
GEORGE GHEBRYAL
05/27/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
GEORGE GHEBRYAL
05/27/2026
Special inspection requirement — Maintenance information
GEORGE GHEBRYAL
05/27/2026
Special inspection requirement — HVAC-R and service water heating system controls
GEORGE GHEBRYAL
05/27/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
GEORGE GHEBRYAL
05/27/2026
Special inspection requirement — HVAC-R and service water heating system controls
GEORGE GHEBRYAL
05/27/2026
Special inspection requirement — HVAC-R and service water heating equipment
GEORGE GHEBRYAL
05/27/2026
Special inspection requirement — Maintenance information
GEORGE GHEBRYAL
05/27/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
GEORGE GHEBRYAL
05/27/2026
Special inspection requirement — HVAC-R and service water heating equipment
GEORGE GHEBRYAL
05/27/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
GEORGE GHEBRYAL
04/23/2026
Special inspection requirement — Fire-Resistance Rated Construction
GEORGE GHEBRYAL
04/23/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
GEORGE GHEBRYAL
04/23/2026
Special inspection requirement — Final
GEORGE GHEBRYAL
01/06/2026
Special inspection requirement — Post-installed Anchors
GEORGE GHEBRYAL
01/06/2026
Special inspection requirement — Energy Code Compliance Inspections
GEORGE GHEBRYAL
01/06/2026
Special inspection requirement — Final
GEORGE GHEBRYAL
01/06/2026
Special inspection requirement — Final
GEORGE GHEBRYAL
01/06/2026
Special inspection requirement — Mechanical Systems
GEORGE GHEBRYAL
12/31/2025
Permit issued — Curb Cut
M01272657-I1-CC
08/26/2025
Filed — Alteration
M01272657-I1
12/09/2024
Signed off — Alteration
STRUCTURAL REPAIRS TO FLUSH TRUCK DUMPING FACILITY AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00450444-I1
08/06/2024
Signed off — Alteration
REPLACEMENT OF EXISTING RTU ON EXISTING DUNNAGE.
M00942651-I1
07/11/2024
Permit issued — Mechanical Systems
M00942651-I1-MS
11/09/2023
Permit issued — Mechanical Systems
M00942651-I1-MS
11/06/2023
Filed — Alteration
REPLACEMENT OF EXISTING RTU ON EXISTING DUNNAGE.
M00942651-I1
09/27/2022
Special inspection requirement — Concrete - Cast-In-Place
EDUARDO LIEVANO
09/27/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
EDUARDO LIEVANO
09/27/2022
Special inspection requirement — Structural Steel - Welding
EDUARDO LIEVANO
09/26/2022
Filed — Alteration
STRUCTURAL REPAIRS TO FLUSH TRUCK DUMPING FACILITY AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00450444-P2
05/24/2021
Permit issued — Structural
M00450444-I1-ST
05/08/2021
Permit issued — Structural
M00450444-I1-ST
05/03/2021
Filed — Alteration
STRUCTURAL REPAIRS TO FLUSH TRUCK DUMPING FACILITY AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00450444-P1
03/01/2021
Filed — Alteration
STRUCTURAL REPAIRS TO FLUSH TRUCK DUMPING FACILITY AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00450444-I1
12/13/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/13/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/20/2003
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
03/20/2003
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
03/20/2003
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
02/19/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/08/2001
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/10/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/20/1999
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/06/1998
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/13/1997
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
Latest 60 of 63 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedON-TRAC CONSTRUCTION ASSO08/04/2026
DOB NOWGeneral ConstructionPermit IssuedON-TRAC CONSTRUCTION ASSO08/04/2026
DOB NOWCurb CutPermit IssuedD'ONOFRIO GENERAL CONTRAC12/31/2025
DOB NOWMechanical SystemsSigned-offACME INDUSTRIAL INC07/11/2024
DOB NOWMechanical SystemsSigned-offACME INDUSTRIAL INC11/09/2023
DOB NOWStructuralSigned-offONSITE CONSTRUCTION ENTER05/24/2021
DOB NOWStructuralSigned-offONSITE CONSTRUCTION ENTER05/08/2021
BISOTISSUEDJCC CONSTRUCTION CORP02/14/2019
BISPLISSUEDJCC CONSTRUCTION CORP02/14/2019
BISOTISSUEDE.C.I. BUILDING CORP07/27/2017
BISPLISSUEDBROOK PLUMBING & HTG CORP11/10/2016
BISOTRE-ISSUEDE.C.I. BUILDING CORP06/30/2016
BISPLISSUEDWIESENBERG INC12/14/2015
BISOTISSUEDD'ONOFRIO GENERAL CONTRACTORS10/13/2015
BISFPISSUEDEMDI LTD02/13/2015
BISOTISSUEDSWIFT CONTRACTING & MAINT10/15/2013
BISOTISSUEDSWIFT CONTRACTING & MAINT10/08/2013
BISMHISSUEDE.C.I. BUILDING CORP04/20/2006
BISMHISSUEDAIRMONT INC03/07/2006
BISEQISSUEDE.C.I. BUILDING CORP12/06/2005
BISPLISSUEDBROOK PLUMBING & HTG CORP10/14/2005
BISMHISSUEDE.C.I. BUILDING CORP10/03/2005
BISMHISSUEDCON EDISON COMPANY INC08/23/2005
BISFPISSUEDELITE ACTION FIRE EXTING. EQU S07/14/2005
BISFPISSUEDELITE ACTION FIRE EXTING. EQU S05/02/2005
BISOTISSUEDD'ONOFRIO GENERAL CONTRACTORS04/15/2005
BISMHISSUEDPROFEESIONAL ENVRMTL SYSTEMS11/05/2004
BISOTISSUEDCON EDISON COMPANY INC04/06/2004
BISMHISSUEDCON EDISON COMPANY INC05/10/2001
BISPLISSUEDBROOK PLUMBING & HTG CORP01/16/2001
BISOTISSUEDE.C.I. BUILDING CORP01/02/2001
BISOTISSUEDE.C.I. BUILDING CORP04/12/2000
BISOTISSUEDE.C.I. BUILDING CORP02/26/1999
BISPLISSUEDSHARP PLUMBING01/12/1999
BISOTISSUEDE.C.I. BUILDING CORP12/29/1998
BISOTISSUEDE.C.I. BUILDING CORP03/30/1998
BISPLISSUEDBROOK PLUMBING & HTG CORP07/25/1996
BISMHISSUEDE.CI. BUILDING CORP01/30/1996
BIS—ISSUEDNORTH SHORE NEON SIGN01/24/1996
BISOTISSUEDE.C.I. BUILDING CORPORATION11/09/1994
1 project · most recent 07/01/2026
Air Conditioning Systems Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
07/01/2026Permit IssuedON-TRAC CONSTRUCTION ASSOAir Conditioning Systems, Heating and Air Conditioning Systems, Ventilation Systems
Cooling
Daikin RTXA60AAVJU 5 tons · Condensing Unit ×3
RXTA24AAVJU 2 tons · Vrf Outdoor ×3
5MXM48VJU9 4 tons · Condensing Unit ×1
Heat / Cool
Daikin DPHS15B 3,800 CFM · Heat Pump Outdoor ×1
DPHS17B 6,200 CFM · Heat Pump Outdoor ×1
DPSH15B 6,200 CFM · Heat Pump Outdoor ×1
Ventilation
Daikin DPSH12B 4,000 CFM · Doas ×1
DPSH20B 5,400 CFM · Doas ×1
1 project · most recent 07/01/2026
Gas Water/Sanitary
FiledStatusContractorScope
07/01/2026——Gas, Water/Sanitary
9 projects · most recent 05/26/2026
General Wiring Lighting
FiledStatusContractorScope
05/26/2026Permit IssuedCONSOLIDATED EDISON COGeneral Wiring
07/31/2024CompleteR. GUNZER, INC.Lighting
01/19/2024CompleteCONSOLIDATED EDISON CO—
11/28/2023CompletePOWERONE ELECT'L CONTRGGeneral Wiring
08/23/2023CompleteCONSOLIDATED EDISON CO—
06/08/2023CompleteCONSOLIDATED EDISON CO—
02/15/2023CompleteCONSOLIDATED EDISON CO—
03/11/2022CompleteCONSOLIDATED EDISON CO—
02/02/2021CompleteCONSOLIDATED EDISON COGeneral Wiring
1 project · most recent 07/01/2026
Steel Concrete
FiledStatusContractorScope
07/01/2026Permit IssuedON-TRAC CONSTRUCTION ASSOSteel, Concrete
▾Special Inspection Requirements (DOB NOW) — 41
DateRequirementInspectorRole
06/17/2026Fenestration air leakageGEORGE GHEBRYALenergy_progress
06/17/2026Fenestration and door U-factor and product ratingsGEORGE GHEBRYALenergy_progress
06/17/2026Fenestration areasGEORGE GHEBRYALenergy_progress
06/12/2026Energy Code Compliance InspectionsGEORGE GHEBRYALprogress
06/05/2026Concrete - Cast-In-PlaceGEORGE GHEBRYALspecial
06/05/2026Structural Steel - High Strength BoltingGEORGE GHEBRYALspecial
05/29/2026Structural Steel - DetailsGEORGE GHEBRYALspecial
05/29/2026Structural Steel - WeldingGEORGE GHEBRYALspecial
05/27/2026Energy Code Compliance InspectionsGEORGE GHEBRYALprogress
05/27/2026HVAC-R and service water piping design and insulationGEORGE GHEBRYALenergy_progress
05/27/2026Maintenance informationGEORGE GHEBRYALenergy_progress
05/27/2026HVAC-R and service water heating system controlsGEORGE GHEBRYALenergy_progress
05/27/2026HVAC-R and service water piping design and insulationGEORGE GHEBRYALenergy_progress
05/27/2026HVAC-R and service water heating system controlsGEORGE GHEBRYALenergy_progress
05/27/2026HVAC-R and service water heating equipmentGEORGE GHEBRYALenergy_progress
05/27/2026Maintenance informationGEORGE GHEBRYALenergy_progress
05/27/2026Fire-Resistant Penetrations and JointsGEORGE GHEBRYALspecial
05/27/2026HVAC-R and service water heating equipmentGEORGE GHEBRYALenergy_progress
05/27/2026Fire-Resistant Penetrations and JointsGEORGE GHEBRYALspecial
04/23/2026Fire-Resistance Rated ConstructionGEORGE GHEBRYALprogress
04/23/2026Fire-Resistant Penetrations and JointsGEORGE GHEBRYALspecial
04/23/2026FinalGEORGE GHEBRYALprogress
01/06/2026Post-installed AnchorsGEORGE GHEBRYALspecial
01/06/2026Energy Code Compliance InspectionsGEORGE GHEBRYALprogress
01/06/2026FinalGEORGE GHEBRYALprogress
Latest 25 of 41.
▾Documents — 192 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch6
08/28/2026M00942651-I1Request digital key ↗
08/21/2026M01272657-I1Request digital key ↗
08/16/2026M01342629-I1Request digital key ↗
Showing 3 of 6 on file for this type
▸DOB NOWPlans/Sketch - Structural3
09/03/2026M00450444-P2Request digital key ↗
09/03/2026M00450444-I1Request digital key ↗
09/03/2026M00450444-P1Request digital key ↗
▸Applications & Permits26
▸BISPLAN / WORK APPROVAL APPLICATION15
01/16/2019123658096Open ↗
01/26/2016122655260Open ↗
01/25/2016122655260Open ↗
Showing 3 of 15 on file for this type
▸BISWORK PERMIT APPLICATION11
02/14/2019123658096Open ↗
02/14/2019123658096Open ↗
11/16/2016122655260Open ↗
Showing 3 of 11 on file for this type
▸Seals & Professional Certifications73
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION27
01/16/2019123658096Open ↗
01/07/2019122655260Open ↗
11/27/2018122655260Open ↗
Showing 3 of 27 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature17
08/30/2026M01342629-S3Open ↗
08/30/2026M01342629-S3Open ↗
08/29/2026M00450444-I1Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWProgress Inspector Seal & Signature10
08/30/2026M01342629-S3Open ↗
08/29/2026M00450444-I1Open ↗
08/27/2026M01342629-I1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature9
09/03/2026M00450444-P1Open ↗
09/03/2026M00450444-P2Open ↗
09/03/2026M00450444-I1Open ↗
Showing 3 of 9 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST5
01/16/2019123658096Open ↗
02/10/2016122655260Open ↗
10/10/2015122535541Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT4
01/16/2019123658096Open ↗
01/26/2016122655260Open ↗
10/10/2015122535541Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
09/06/2013121764778Open ↗
▸Trade Schedules & Equipment6
▸BISFA - FDNY APPROVAL : FD-FAA3
07/08/2024104015281Open ↗
12/17/2018121763458Open ↗
12/11/2014121764787Open ↗
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE3
01/16/2019123658096Open ↗
01/25/2016122655260Open ↗
10/10/2015122535541Open ↗
▸Environmental & Asbestos17
▸BISASBESTOS: CERTIFICATION (DEP ACP5)8
01/16/2019123658096Open ↗
01/26/2016122655260Open ↗
06/30/2014122045688Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
09/03/2026M00450444-P2Open ↗
09/03/2026M00450444-P1Open ↗
09/03/2026M00450444-I1Open ↗
Showing 3 of 7 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
03/21/2008110120716Open ↗
▸BISASBESTOS: EXEMPTION (ASB4)1
10/10/2015122535541Open ↗
▸Energy Compliance10
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS5
03/06/2018122535541Open ↗
10/10/2015122535541Open ↗
06/30/2014122045688Open ↗
Showing 3 of 5 on file for this type
▸BISTR8: Energy Code Progress Inspections4
11/11/2014121764778Open ↗
11/03/2014121764778Open ↗
10/15/2014122041049Open ↗
Showing 3 of 4 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS1
03/06/2018122535541Open ↗
▸Inspections & Test Reports10
▸BISTECHNICAL REPORT: CONCRETE/TEST CYLINDER5
11/27/2018122655260Open ↗
11/27/2018122655260Open ↗
03/06/2018122535541Open ↗
Showing 3 of 5 on file for this type
▸BISTECHNICAL REPORT: CONCRETE DESIGN MIX2
07/01/2016122655260Open ↗
11/03/2015122535541Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY1
05/30/2024123658096Open ↗
▸BISTECHNICAL REPORT: PILE DRIVING1
11/27/2018122655260Open ↗
▸BISTECHNICAL REPORT: SOIL INSPECTION1
01/25/2016122655260Open ↗
▸Approvals, Objections & Sign-offs3
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
01/07/2019122655260Open ↗
11/28/2018122655260Open ↗
03/06/2018122535541Open ↗
▸Cost, Insurance & Ownership19
▸BISCOST AFFIDAVIT17
01/16/2019123658096Open ↗
01/07/2019122655260Open ↗
03/06/2018122535541Open ↗
Showing 3 of 17 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW32
12/09/2025121763458Open ↗
03/09/2022104015281Open ↗
▸Filing & Intake Forms16
▸BISEFILING COVER SHEET12
01/16/2019123658096Open ↗
01/26/2016122655260Open ↗
01/25/2016122655260Open ↗
Showing 3 of 12 on file for this type
▸BISBOROUGH INTAKE FORM3
01/07/2019122655260Open ↗
11/28/2018122655260Open ↗
03/06/2018122535541Open ↗
▸BISADDITIONAL INFORMATION1
06/17/2014121764778Open ↗
▸Other Documents3
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION2
11/27/2018122655260Open ↗
02/09/2016122655260Open ↗
▸BISSupporting Document: Fee Exempt1
06/30/2014122045688Open ↗