ECB05/07/2026FAILURE TO OBTAIN A TEMPORARY CONTRACTION PERMIT PRIOR TO INSTALLATION/USE OF TEMPORARY CONSTRUCTION EQUIPMENT. AT THE TIME OF INSPECTION I OBSERVED CONSTRUCTION FENCE IN PLACE WITHOUT ISSUED PERMIT. REMEDY: OB$6K due
ECB05/07/2026FAILURE TO OBTAIN A TEMPORARY CONTRACTION PERMIT PRIOR TO INSTALLATION/USE OF TEMPORARY CONSTRUCTION EQUIPMENT. AT THE TIME OF INSPECTION I OBSERVED PIPE SCAFFOLDING ON EXPOSURE 4 WITH NO PERMIT ISSUED. REMEDY:$6K due
DOB05/07/2026FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.AS NOTED AT TH E TIME OF INSPECTION,OBSERVED ON EXP1 WEST ELEV,SPALLING STONE,MISSING /DAMAGED MORTAR JOINTS IN STONE WALL.EXP2 NORTH ELEV ERODED MORTAR JOI NTS IN BRICK WALL IN MULTIPLE LOCATIONS.EXP3 EAST ELEV ERODED MORAT JO INTS IN BRICK AND STONE WALL IN MULTI LOCATIONS.REMEDY:REPAIR/REPLACE
ECB05/05/2026AT TIME OF INSPECTION OF 2 STORY VACANT CHURCH OBSERVED SIDEWALK SHED IN PLACE WITH VALID PERMITS AND MISSING INFORMATION PANEL CAUSING HAZARDOUS CONDITIONS.PROVIDE INFORMATION PANEL$1K due
DOB11/14/2025VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
ECB03/11/2025AT TIME OF INSPECTION OBSERVED THAT PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION. OBSERVED SHED PARAPET PANEL, LOOSE/DETACH AND DAMAGE SECTIONS ON WEST 141 STREET. REMEDY: COMPLY WITH CODE SPECIFICATI$10K due
DOB03/07/2025EMERGENCY WORK ORDER DUE TO LOOSE/DETACH SHED PANEL AT EXPOSURE 1 WEST 141 STREET. THIS CONDITION IS VERY DETRIMENTAL TO PUBLIC SAFETY REMEDY: IMMEDIATELY MAKE REPAIR OF UNDER A SUPERVISION OF A PROFESSIONAL PERSONS
DOB03/07/2025FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: OBSERVED AT EXP 1 WEST ELEVATION DAMAGED BROWN STONES AND DAMAGED JOINTS. EXPOSURE 2 DAMAGED JOINTS AND SPALLING. EXPOSURE 3 MISSING STONE DAMAGED JOINTS AND SPALLING. EXPOSURE 1 DAMAGED ROOF. REMEDY: REPAIR AND/OR REPLACE
ECB02/10/2025AT TIME OF INSPECTION OF A 2 STORY VACATE BUILDING OBSERVED NO SIGN OF CONSTRUCTION ACTIVITIES DURING MY INSPECTION I OBSERVED SIDEWALK SHED MAINTAIN AS PER CODE 3307.6.4.10 FOUNDING.OBSERVED VARIOUS VERTICAL P$10K due
ECB11/14/2024AT TIME OF INSPECTION OBSERVED SIDEWALK SHED IN PLACE WITH LIGHTING NOT IN OPERATING CONDITIONS CAUSING A HAZARD.PROVIDE LIGHTING AS REQUIRED$10K due
ECB10/31/2024AT TIME OF INSPECTION ON A 2 STORIES OBSERVED SIDEWALK SHED AT EXPO#1 WITH NO LIGHT UNDER THE SIDEWALK SHED AT 5:30AM CREATING UNSAFE CONDITION FOR PEDESTRIAN 3307.6.4.8 LIGHTING..$10K due
ECB10/03/2024TEMPORARY CONSTRUCTION EQUIPPMENT ON SITE EXPIRED PERMIT. NOTE: AT TIME OF INSPECTION OBSERVED GREEN CONSTRUCTION FENCE LOCATED ON THE PREMISES. NO PERMITS WERE POSTED NOR WAS THERE ANY VALID PERMIT ON BIS OR D$6K due
ECB10/03/2024SIDEWALK SHED DOES NOT MEET CODE SPECIFICATIONS. NOTE-OBSERVED ROTTEN/BROKEN SWS MUDSILLS AT MULTIPLE LOCATIONS OBSEVRED SHED PARAPET WALLS FALLEN ON TO THE SHED/NOT PROPER TO SPECIFICATIONS. REMEDY: CONFORM SH$10K due
DOB10/03/2024FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. NOTE: AT TIME OF INSPECTION AT EXPOSURE #4 OBSERVED DAMAGED ROOF WITH HOLE IN ROOF AT MULTIPLE LOCATIONS. AT EXPOSURE #2 OBSERVED DAMAGE MORTAR JOINTS. REMEDY: REPAIR/REPLACE
DOB09/23/2024VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION
DOB05/14/2024FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.NOTE OBSERVED SINKING/DETERIORATING ROOF THROUGHOUT ITS PERIMETER.REMEDY:FIX AND/OR REPLACE
ECB05/14/2024SIDEWALK SHED DOES NOT MEET CODE SPECIFICATIONS. NOTE:-OBSERVED ROTTEN/BROKEN SWS MUDSILLS AT MULTIPLE LOCATIONS. REMEDY: CONFORM SHED TO ODE SPECIFICATIONS.$10K due
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
ECB06/19/2023AT TIME OF INSPECTION OF 2 STORY BUILDING INACTIVE JOBSITE OBSERVED SWS INSTALLED AT EXP1,4 UPON REVIEW DOB RECORDS IT WAS OBSERVED THE SWS PERMIT # M00104770 WAS EXPIRED ON 04/13/2023 AND HAS NOT BEEN RENEWED,$10K due
DOB06/17/2023VEHICLE IMPACTING SIDEWALK SHED
DOB04/25/2023VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
ECB06/13/2022SIDEWALK SHED LIGHTS NOT IN OPERATING CONDITION.PROVIDED$10K due
DOB05/19/2022EWO-THE FLOOR ASSEMBLY OVER ORGAN PARTLY COLLPSD ON 5/17/22PE RPRT ALSO STATES WATER DMG & DTERIORATN WAS OBSVD AROUND AREA UNDRACTIVE ROOF LEAK IN EXP2/3 CORNER OF BLDG & DTERIORTD JOIST @EXP1 1FL IMMED INSTALL TEMP SHORING & BRACING & OVERHEAD PROTECTN PER PE ONSITE .FILE FOR PRMT W/IN 2 BUS DAYS WRK STRTS
DOB04/26/2022EMERG WORK-INSPCTN 2/1/19-APPRX 6"W X 12"D HOLE IN VALLEYROOF ADJ TO REAR CHIMNEY@EXP2 BLDG SIDE WHICH ALLOWS EXCESSIVE WATER INFILTRATION INTO BLDG.AREAS DETERIORTD ROOF DECK &JOIST APPRX 2'X8' IMMED INSTL NEW TEMP ROOF W/TEMP ROOF DECKNG&FRMNG AS REQRD PER PE ENGR TO DIRCTLY SUPERV&DIRCT ALL WRK ON SITE BY CONTR
ECB10/01/2021TEMPORARY CONSTRUCTION EQUIPMENT ONSITE - EXPIRED PERMIT. APPROXIMATELY 200 LF OF SWS PRESENT AT EXP #1 & #2 UNDER PERMIT #M00104770-I1-SH WHICH EXPIRED 04/06/2019. NO UPDATED PERMIT FOR SWS OBSERVED., RENEW PE$1K due
DOB11/08/2019VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
DOB10/29/2018FAILURE TO MAINTAIN-NYS PE&RA TO EVALUATE ENT BLDG IMMED TO INSTALL BARRIERS TO BLOCK ACCESS TO UNSAFE AREAS REMEDIATE SAFETY HAZARDS AND EVALUATE REQUIRED EGRESS SUBMIT ACCESS&PROTECTION PLAN TO DOB 11/8/18 SPACE FOR SERVICES NOT ALLOWED ON 1ST FL LEVEL W/O DOB APPROVAL OF SAF ETY PLAN SUBMIT BUILDING EVALUATION REPORTS BY PE&RA BY 11/21/18
DOB10/29/2018EMERGENCY WORK-IMMEDIATELY INSTALL NETTING AT DIRECTION OF PE TO REMED IATE SAFETY HAZARDS. NYS PE TO DIRECT AND OVERSEE ALL WORK ON SITE.FIL E FOR PERMIT WITH IN TWO DAYS OF WORK START. WORK TO START NO LATER THAN 11/1/18
DOB10/19/2018V-DOB VIOLATION - ACTIVE
DOB04/06/2018VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
DOB02/24/2017VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT
DOB03/01/2013VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT
DOB10/24/2012FAILURE TO MAINTAIN BUILDING DUE TO CAR ACCIDENT
DOB12/13/2011VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT
DOB01/19/2007V-DOB VIOLATION - ACTIVE
DOB09/16/1997V-DOB VIOLATION - ACTIVE
DOB02/10/1997V-DOB VIOLATION - ACTIVE
ECB04/16/2024AT THE TIME OF INSPECTION, I OBSERVED A CONSTRUCTION SITE FENCE AT ABOVE LOCATION THAT IS NOT MAINTAINED. CONSTRUCTION SITE FENCE IS COVERED IN GRAFFITI, POSTERS, AND NOT FULLY MAINTAINED WITH HUNTER GREEN AS RNothing owed — awaiting certificate of correction
ECB10/16/2021FAILURE TO MAINTAIN ACTIVE PERMIT FOR TEMPORARY CONSTRUCTION EQUIPMENTSIDEWALK SHED.AT TIME OF INSPECTION ON AN INACTIVE 2 STORY ALT CONSTRUCTION SITE NOTICE AT TWO EXPOSURES OF THE BUILDING 2 SIDEWALK SHED WHENothing owed — awaiting certificate of correction
ECB10/19/2018FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES. NOTED: THE EXTERIOR WALLS AT EXP #3 & #4 WERE IN DISREPAIR & COVERED BY A NET TO AVOID BRICKS/DEBRIS FALLING ON THE SIDEWALK. REM: MAINTAIN THE EXTERIOR BUILNothing owed — awaiting certificate of correction
ECB10/19/2018FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: OBSERVED THE CEILING & WALLS WERE IN DISREPAIR. MANY VERTICAL & HORZONTAL CRACKS ARE PRESENT ON THE WALLS & COLUMNS. THE MOST OF THE DEFECTS ARE LOCNothing owed — awaiting certificate of correction