← Back
Two family brick
2813 AVENUE D
BROOKLYN · BIN 3119989
💬 Discuss this project
1910Year Built
2Stories
B1Building Class
R6Zoning
1,800 sfGross Floor Area
2Units
Rent Stabilized1 Open Violation ▸FDNY Report ↗
Two family brick · 1,040 sf lot · 1.73 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbing
Cellar12p · 1 filing · 20 docs
1 job · most recent 03/13/2024
Gas Water/Sanitary
FiledStatusContractorScope
03/13/2024Permit IssuedTRI CITY MECHANICAL GROUPGas, Water/Sanitary
Building Lifecycle
All (26)Filed (3)Permit Issued (2)Violation (4)Inspection (6)Objection (2)Special Inspection (9)
11/24/2025
Violation issued (HPD, open)
I
12/04/2024
Violation issued (HPD, closed)
I
08/05/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/25/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/22/2024
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
03/22/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
03/14/2024
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
03/14/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
03/13/2024
Filed — Alteration
SUBSEQUENT FILING FOR PLUMBING WORK TYPE ONLY TO ADD NEW 3 PCS BATHROOM IN CELLAR, ADD ONE NEW GAS METER FOR EXISTING BOILER EXISTING, NEW WATER HEATER, AND NEW DRYER.
B00967912-P1
03/11/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
KENNETH PHILOGENE
03/11/2024
Special inspection requirement — Energy Code Compliance Inspections
KENNETH PHILOGENE
03/11/2024
Special inspection requirement — Maintenance information
KENNETH PHILOGENE
03/11/2024
Special inspection requirement — HVAC-R and service water heating equipment
KENNETH PHILOGENE
03/11/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
KENNETH PHILOGENE
03/11/2024
Special inspection requirement — HVAC-R and service water heating system controls
KENNETH PHILOGENE
02/20/2024
Permit issued — Plumbing
B00967912-S1-PL
02/20/2024
Permit issued — General Construction
B00967912-I1-GC
02/05/2024
Objection resolved — Addressed
02/02/2024
Objection raised — Other
01/31/2024
Filed — Alteration
SUBSEQUENT FILING FOR PLUMBING WORK TYPE ONLY TO ADD NEW 3 PCS BATHROOM IN CELLAR, ADD ONE NEW GAS METER FOR EXISTING BOILER EXISTING, NEW WATER HEATER, AND NEW DRYER.
B00967912-I1
01/31/2024
Filed — Alteration
SUBSEQUENT FILING FOR PLUMBING WORK TYPE ONLY TO ADD NEW 3 PCS BATHROOM IN CELLAR, ADD ONE NEW GAS METER FOR EXISTING BOILER EXISTING, NEW WATER HEATER, AND NEW DRYER.
B00967912-S1
11/28/2023
Violation issued (HPD, closed)
I
11/27/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
KENNETH PHILOGENE
11/27/2023
Special inspection requirement — Energy Code Compliance Inspections
KENNETH PHILOGENE
11/27/2023
Special inspection requirement — Lighting in dwelling units
KENNETH PHILOGENE
11/18/2022
Violation issued (HPD, closed)
I
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
COBBLA HOLDINGS1007/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KCE CONSULTING ENGINEERING PLLC303/13/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KP CONSULTING ENGINEER603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PM MECHANICAL GROUP CORPGeneral Contractor303/21/2026
TRI CITY MECHANICAL GROUP CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
KMP DESIGN & ENGINEERING1630303/13/2024
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedFLAVIO MECHANICAL CORP02/20/2024
DOB NOWGeneral ConstructionPermit IssuedPM MECHANICAL GROUP CORP02/20/2024
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
08/05/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/25/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/22/2024Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
03/22/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/14/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
03/14/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
03/11/2024Fire-Resistant Penetrations and JointsKENNETH PHILOGENEspecial
03/11/2024Energy Code Compliance InspectionsKENNETH PHILOGENEprogress
03/11/2024Maintenance informationKENNETH PHILOGENEenergy_progress
03/11/2024HVAC-R and service water heating equipmentKENNETH PHILOGENEenergy_progress
03/11/2024HVAC-R and service water piping design and insulationKENNETH PHILOGENEenergy_progress
03/11/2024HVAC-R and service water heating system controlsKENNETH PHILOGENEenergy_progress
11/27/2023Fire-Resistant Penetrations and JointsKENNETH PHILOGENEspecial
11/27/2023Energy Code Compliance InspectionsKENNETH PHILOGENEprogress
11/27/2023Lighting in dwelling unitsKENNETH PHILOGENEenergy_progress
▾Documents — 25 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/26/2026B00967912-P2Request digital key ↗
08/26/2026B00967912-P1Request digital key ↗
08/26/2026B00967912-S1Request digital key ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records4
▸DOB NOWRestrictive Declaration/Easement 14
08/13/2026B00967912-P1Open ↗
08/13/2026B00967912-S1Open ↗
08/13/2026B00967912-I1Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications13
▸DOB NOWProgress Inspector Seal & Signature7
09/18/2026B00967912-I1Open ↗
09/18/2026B00967912-I1Open ↗
08/26/2026B00967912-P1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/26/2026B00967912-S1Open ↗
08/26/2026B00967912-I1Open ↗
08/26/2026B00967912-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
09/18/2026B00967912-I1Open ↗
08/26/2026B00967912-P1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/26/2026B00967912-P1Open ↗
08/26/2026B00967912-S1Open ↗
08/26/2026B00967912-P2Open ↗
Showing 3 of 4 on file for this type