← Back
Condo, residential tower (mixed-use, multi-family elevator) [derived]
The 282 South Fifth Street Condominium
284 SOUTH 5 STREET · Williamsburg · BIN 3335970
💬 Discuss this project
2014Year Built
13Stories
RMBuilding Class
C4-3Zoning
140,836 sfGross Floor Area
83Units
LL97 CoveredRent Stabilized
Condo, residential tower (mixed-use, multi-family elevator) [derived] · 28,000 sf lot · 5.03 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionGeneral
Roof7p · 2 filings · 20 docs
Floor 51p · 1 filing · 2 docs
Floor 41p · 1 filing · 2 docs
Floor 31p · 1 filing · 2 docs
Floor 25p · 2 filings · 9 docs
Floor 130p · 5 filings · 20 docs
Site & exterior9p · 12 filings · 20 docs
Filed — no permit issued3p · 1 filing · 6 docs
Nothing on file for this building.
Nothing on file for this building.
Nothing on file for this building.
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 12
DateTypeResultReport
09/09/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/19/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
03/18/2022Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
03/15/2022Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
03/09/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
11/24/2021Certified Gas-Gas-Piping-RoughingCertifiedView ↗
11/24/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/20/2021Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
08/17/2021Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
08/17/2021Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
06/29/2021Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/23/2021Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 25
DateRequirementInspectorRole
05/08/2026Public Assembly Emergency LightingDaniel Henkelprogress
05/08/2026FinalThomas Scibiliaprogress
04/24/2026Public Assembly Emergency LightingDaniel Henkelprogress
04/23/2026FinalThomas Scibiliaprogress
10/23/2025FinalRyan Hungprogress
10/23/2025FinalRyan Hungprogress
06/22/2022Sprinkler SystemsMichael Tobiasspecial
11/11/2021FinalRichard Wainerprogress
11/01/2021Maintenance informationERIC BERLENTenergy_progress
11/01/2021Mechanical SystemsERIC BERLENTspecial
11/01/2021FinalERIC BERLENTprogress
11/01/2021HVAC and service water heating equipment ERIC BERLENTenergy_progress
11/01/2021HVAC and service water heating system controls ERIC BERLENTenergy_progress
11/01/2021HVAC insulation and sealing ERIC BERLENTenergy_progress
11/01/2021Shutoff dampersERIC BERLENTenergy_progress
10/18/2021Mechanical SystemsERIC BERLENTspecial
10/18/2021HVAC and service water heating equipment ERIC BERLENTenergy_progress
10/18/2021HVAC and service water heating system controls ERIC BERLENTenergy_progress
10/18/2021FinalERIC BERLENTprogress
10/18/2021Shutoff dampersERIC BERLENTenergy_progress
10/18/2021Maintenance informationERIC BERLENTenergy_progress
10/18/2021HVAC insulation and sealing ERIC BERLENTenergy_progress
08/31/2021Sprinkler SystemsNicolas Crosettospecial
01/06/2021FinalRichard Wainerprogress
11/27/2017FinalRichard Wainerprogress
Nothing on file for this building.