Locations of Work
ArchitectureStructuralMechanicalPlumbingFire Protection
Roof20p · 1 filing · 20 docs
Floor 320p · 2 filings · 20 docs
Floor 221p · 2 filings · 20 docs
Floor 117p · 1 filing · 20 docs
Cellar20p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MNK ENTERPRISES LLC503/22/2026
284 SUYDAM LP103/22/2026
PATOMA103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/03/2022$2.0M—THE SALERNO QUALIFIED PERSONAL RESIDENCE TRUST → 284 SUYDAM LP$391/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SALEH & ASSOCIATES710/04/2023
ENTHINK ENGINEERS LLC112/22/2022
ALNOV ENGINEERING, P.C.203/29/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BMB BUILDING CONSULTING1803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PATOMA INCGeneral Contractor1507/08/2026
MNK ENTERPRISES LLCGeneral Contractor303/21/2026
ORBIT SPRINKLER CORPFire Protection107/08/2026
ORBIT PLBG & HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CITY-WIDE TESTING INC416910/04/2023
Building Lifecycle
All (166)Filed (10)Permit Issued (10)Signed Off (5)Violation (37)Inspection (10)Objection (64)Special Inspection (30)
05/06/2026
Violation issued (HPD, closed)
A
01/30/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
11/28/2023
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
11/22/2023
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
11/22/2023
Inspection — Certified Sprinkler - SP - Roughing
Certified
View inspection ↗
10/06/2023
Special inspection requirement — Metering
ELIAS RASABI
10/06/2023
Special inspection requirement — Fenestration areas
ELIAS RASABI
10/06/2023
Special inspection requirement — Interior lighting power
ELIAS RASABI
10/06/2023
Special inspection requirement — Air barrier - visual inspection
ELIAS RASABI
10/06/2023
Special inspection requirement — Fenestration air leakage
ELIAS RASABI
10/06/2023
Special inspection requirement — Fire-Resistance Rated Construction
ELIAS RASABI
10/06/2023
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
ELIAS RASABI
10/06/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
ELIAS RASABI
10/06/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
ELIAS RASABI
10/06/2023
Special inspection requirement — Insulation placement and R values
ELIAS RASABI
10/06/2023
Special inspection requirement — Energy Code Compliance Inspections
ELIAS RASABI
10/04/2023
Filed — Alteration CO
PROPOSE GENERAL CONSTRUCTION OF EXISTING 3-STORY NEW LAW TENEMENT BUILDING, INCREASE EXISTING 3 APTS TO 7 APTS. NO CHANGE TO EXISTING BUILDING BULK AREA & HEIGHT. OBTAIN A NEW C OF O. RELATED SPRINKLER, PLUMBING, MECHANICAL, & STRUCTURAL FILED SEPARATELY.
B00631918-P3
06/30/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/23/2023
Signed off — Alteration
PROPOSE PLUMBING WORK FOR EXISTING 3-STORY NEW LAW TENEMENT BUILDING FROM EXISTING 3 APTS TO 7 APTS FILED IN CONJUNCTION WITH ALT-CO JOB #B00631918-I1.
B00651955-I1
06/23/2023
Signed off — Alteration
PROPOSE NEW MECHANICAL WORK FOR EXISTING 3-STORY NEW LAW TENEMENT BUILDING FILED IN CONJUNCTION WITH ALT-CO JOB #B00631918-I1.
B00651808-I1
06/22/2023
Signed off — Alteration CO
PROPOSE GENERAL CONSTRUCTION OF EXISTING 3-STORY NEW LAW TENEMENT BUILDING, INCREASE EXISTING 3 APTS TO 7 APTS. NO CHANGE TO EXISTING BUILDING BULK AREA & HEIGHT. OBTAIN A NEW C OF O. RELATED SPRINKLER, PLUMBING, MECHANICAL, & STRUCTURAL FILED SEPARATELY.
B00631918-S1
06/22/2023
Signed off — Alteration CO
PROPOSE GENERAL CONSTRUCTION OF EXISTING 3-STORY NEW LAW TENEMENT BUILDING, INCREASE EXISTING 3 APTS TO 7 APTS. NO CHANGE TO EXISTING BUILDING BULK AREA & HEIGHT. OBTAIN A NEW C OF O. RELATED SPRINKLER, PLUMBING, MECHANICAL, & STRUCTURAL FILED SEPARATELY.
B00631918-S2
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/15/2023
Special inspection requirement — Sprinkler Systems
ELIAS RASABI
06/15/2023
Special inspection requirement — Maintenance information
ELIAS RASABI
06/15/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
ELIAS RASABI
06/15/2023
Special inspection requirement — Energy Code Compliance Inspections
ELIAS RASABI
06/13/2023
Filed — Alteration CO
PROPOSE GENERAL CONSTRUCTION OF EXISTING 3-STORY NEW LAW TENEMENT BUILDING, INCREASE EXISTING 3 APTS TO 7 APTS. NO CHANGE TO EXISTING BUILDING BULK AREA & HEIGHT. OBTAIN A NEW C OF O. RELATED SPRINKLER, PLUMBING, MECHANICAL, & STRUCTURAL FILED SEPARATELY.
B00631918-P2
06/12/2023
Objection resolved — Addressed
06/05/2023
Objection resolved — Addressed
05/31/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
05/31/2023
Objection raised — Scope
05/17/2023
Objection resolved — Addressed
05/17/2023
Objection resolved — Addressed
05/15/2023
Objection raised — Scope
05/12/2023
Objection raised — Admin
05/10/2023
Filed — Alteration
PROPOSE PLUMBING WORK FOR EXISTING 3-STORY NEW LAW TENEMENT BUILDING FROM EXISTING 3 APTS TO 7 APTS FILED IN CONJUNCTION WITH ALT-CO JOB #B00631918-I1.
B00651955-P1
05/09/2023
Objection raised — Scope
05/05/2023
Filed — Alteration CO
PROPOSE GENERAL CONSTRUCTION OF EXISTING 3-STORY NEW LAW TENEMENT BUILDING, INCREASE EXISTING 3 APTS TO 7 APTS. NO CHANGE TO EXISTING BUILDING BULK AREA & HEIGHT. OBTAIN A NEW C OF O. RELATED SPRINKLER, PLUMBING, MECHANICAL, & STRUCTURAL FILED SEPARATELY.
B00631918-P1
05/03/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
ELIAS RASABI
05/03/2023
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
ELIAS RASABI
05/03/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
ELIAS RASABI
05/03/2023
Special inspection requirement — Energy Code Compliance Inspections
ELIAS RASABI
05/03/2023
Special inspection requirement — Fire-Resistance Rated Construction
ELIAS RASABI
05/03/2023
Special inspection requirement — Fenestration air leakage
ELIAS RASABI
05/03/2023
Special inspection requirement — Fenestration areas
ELIAS RASABI
05/03/2023
Special inspection requirement — Air barrier - visual inspection
ELIAS RASABI
05/03/2023
Special inspection requirement — Metering
ELIAS RASABI
05/03/2023
Special inspection requirement — Interior lighting power
ELIAS RASABI
05/03/2023
Special inspection requirement — Insulation placement and R values
ELIAS RASABI
04/26/2023
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
04/25/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/13/2023
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
02/22/2023
Signed off — Alteration
B00802728-I1
02/07/2023
Permit issued — Mechanical Systems
B00651808-I1-MS
02/07/2023
Permit issued — Structural
B00631918-S1-ST
02/01/2023
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
02/01/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/26/2023
Permit issued — General Construction
B00631918-I1-GC
12/23/2022
Permit issued — Sidewalk Shed
B00802728-I1-SH
Latest 60 of 166 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offPATOMA INC02/07/2023
DOB NOWStructuralSigned-offPATOMA INC02/07/2023
DOB NOWGeneral ConstructionPermit IssuedPATOMA INC01/26/2023
DOB NOWSidewalk ShedSigned-offMNK ENTERPRISES LLC12/23/2022
DOB NOWPlumbingSigned-offORBIT SPRINKLER CORP09/23/2022
DOB NOWSprinklersSigned-offORBIT PLBG & HTG INC09/23/2022
DOB NOWMechanical SystemsSigned-offPATOMA INC09/05/2022
DOB NOWGeneral ConstructionPermit IssuedPATOMA INC06/17/2022
DOB NOWFoundationSigned-offPATOMA INC06/13/2022
DOB NOWStructuralSigned-offPATOMA INC06/13/2022
3 projects · most recent 06/16/2023
General Wiring
FiledStatusContractorScope
06/16/2023CompleteINFINITY ELECTRIC, INC8 meters, 8 new_meters
06/09/2023CompleteINFINITY ELECTRIC, INCGeneral Wiring
12/22/2022CompleteRICHARD NEU—
1 project · most recent 10/04/2023
Steel Concrete Masonry Wood
FiledStatusContractorScope
10/04/2023Signed-offPATOMA INCSteel, Concrete, Masonry, Wood
▾Field Inspections (DOB CAP) — 10
DateTypeResultReport
01/30/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
11/28/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
11/22/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
11/22/2023Certified Sprinkler - SP - RoughingCertifiedView ↗
05/31/2023Pass-Final CND-Occupancy InspectionPassView ↗
04/26/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
04/13/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
02/01/2023Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
02/01/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/16/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 40
DateRequirementInspectorRole
10/06/2023MeteringELIAS RASABIenergy_progress
10/06/2023Fenestration areasELIAS RASABIenergy_progress
10/06/2023Interior lighting powerELIAS RASABIenergy_progress
10/06/2023Air barrier - visual inspectionELIAS RASABIenergy_progress
10/06/2023Fenestration air leakageELIAS RASABIenergy_progress
10/06/2023Fire-Resistance Rated ConstructionELIAS RASABIprogress
10/06/2023Exterior Insulation and Finish Systems (EIFS)ELIAS RASABIspecial
10/06/2023Fire-Resistant Penetrations and JointsELIAS RASABIspecial
10/06/2023Fenestration and door U-factor and product ratingsELIAS RASABIenergy_progress
10/06/2023Insulation placement and R valuesELIAS RASABIenergy_progress
10/06/2023Energy Code Compliance InspectionsELIAS RASABIprogress
06/15/2023Sprinkler SystemsELIAS RASABIspecial
06/15/2023Maintenance informationELIAS RASABIenergy_progress
06/15/2023Fire-Resistant Penetrations and JointsELIAS RASABIspecial
06/15/2023Energy Code Compliance InspectionsELIAS RASABIprogress
05/03/2023Fenestration and door U-factor and product ratingsELIAS RASABIenergy_progress
05/03/2023Exterior Insulation and Finish Systems (EIFS)ELIAS RASABIspecial
05/03/2023Fire-Resistant Penetrations and JointsELIAS RASABIspecial
05/03/2023Energy Code Compliance InspectionsELIAS RASABIprogress
05/03/2023Fire-Resistance Rated ConstructionELIAS RASABIprogress
05/03/2023Fenestration air leakageELIAS RASABIenergy_progress
05/03/2023Fenestration areasELIAS RASABIenergy_progress
05/03/2023Air barrier - visual inspectionELIAS RASABIenergy_progress
05/03/2023MeteringELIAS RASABIenergy_progress
05/03/2023Interior lighting powerELIAS RASABIenergy_progress
Latest 25 of 40.
▾Documents — 57 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
08/31/2026B00651955-I1Request digital key ↗
08/30/2026B00631918-P3Request digital key ↗
08/30/2026B00631918-P2Request digital key ↗
Showing 3 of 10 on file for this type
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B00631918-I1Open ↗
▸Seals & Professional Certifications25
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/30/2026B00631918-P1Open ↗
08/30/2026B00631918-S2Open ↗
08/30/2026B00631918-S1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWProgress Inspector Seal & Signature8
09/01/2026B00651955-I1Open ↗
09/01/2026B00651955-I1Open ↗
09/01/2026B00631918-S1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
09/01/2026B00651955-I1Open ↗
09/01/2026B00631918-S1Open ↗
08/28/2026B00631918-P1Open ↗
Showing 3 of 7 on file for this type
▸Safety & Tenant Protection4
▸DOB NOWStreet Tree Checklist4
08/30/2026B00631918-P2Open ↗
08/30/2026B00631918-P3Open ↗
08/15/2026B00631918-P1Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form5
08/15/2026B00631918-S1Open ↗
08/14/2026B00631918-S2Open ↗
08/14/2026B00631918-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/30/2026B00631918-P3Open ↗
08/30/2026B00631918-P2Open ↗
08/15/2026B00631918-P1Open ↗
Showing 3 of 4 on file for this type
▸Energy Compliance3
▸DOB NOWEN2: As Built Energy Analysis3
08/13/2026B00631918-I1Open ↗
08/13/2026B00651808-I1Open ↗
08/13/2026B00651955-I1Open ↗
▸Other Documents5
▸DOB NOWProperty Ownership Certification4
08/30/2026B00631918-P2Open ↗
08/30/2026B00631918-P3Open ↗
08/15/2026B00631918-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWFinal Survey1
08/13/2026B00631918-I1Open ↗