← Back
Two family converted from one family
2842 SAMPSON AVENUE
BRONX · Throgs Neck-Schuylerville · BIN 2080585
💬 Discuss this project
1925Year Built
2Stories
B3Building Class
R3AZoning
1,892 sfGross Floor Area
2Units
Two family converted from one family · 3,800 sf lot · 0.5 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbingGeneral
Floor 27p · 2 filings · 20 docs
Floor 17p · 2 filings · 20 docs
Cellar8p · 2 filings · 20 docs
Site & exterior1p · 1 filing · 3 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ZMIROT1407/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/24/2023$910K—HASDAY, LLC → Private party$481/sf building
04/22/2021$480K—— → —$254/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
J.K.DESIGN404/11/2022
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
RASHBI DEVELOPMENT INCGeneral Contractor407/08/2026
PLBG P & H INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
TRIANGLE INSPECTION & TES7495304/11/2022
Building Lifecycle
All (71)Filed (4)Permit Issued (3)Signed Off (2)Inspection (10)Objection (22)Special Inspection (30)
05/16/2022
Signed off — Alteration
Installation of new gas fired equipment and plumbing fixtures for the renovation and conversion of the existing one family dwelling into a two family dwellings. Filed in conjunction with ALT I application #X00527244
X00592250-I1
05/03/2022
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
05/03/2022
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/29/2022
Special inspection requirement — Air barrier - visual inspection
Rajasekhar Sakhamuri
04/29/2022
Special inspection requirement — Chimneys and vents
Rajasekhar Sakhamuri
04/29/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Rajasekhar Sakhamuri
04/29/2022
Special inspection requirement — Concrete - Cast-In-Place
Rajasekhar Sakhamuri
04/29/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
Rajasekhar Sakhamuri
04/29/2022
Special inspection requirement — Subgrade Inspections
Rajasekhar Sakhamuri
04/29/2022
Special inspection requirement — Energy Code Compliance Inspections
Rajasekhar Sakhamuri
04/29/2022
Special inspection requirement — Fire-Resistance Rated Construction
Rajasekhar Sakhamuri
04/29/2022
Special inspection requirement — Footing and Foundation
Rajasekhar Sakhamuri
04/29/2022
Special inspection requirement — Structural Wood Frame
Rajasekhar Sakhamuri
04/29/2022
Special inspection requirement — Final
Rajasekhar Sakhamuri
04/29/2022
Special inspection requirement — Insulation placement and R values
Rajasekhar Sakhamuri
04/29/2022
Special inspection requirement — Permanent certificate
Rajasekhar Sakhamuri
04/29/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
Rajasekhar Sakhamuri
04/29/2022
Special inspection requirement — Fenestration air leakage
Rajasekhar Sakhamuri
04/29/2022
Special inspection requirement — Interior lighting power
Rajasekhar Sakhamuri
04/29/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
Rajasekhar Sakhamuri
04/29/2022
Special inspection requirement — Fenestration areas
Rajasekhar Sakhamuri
04/22/2022
Objection resolved — Addressed
04/21/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/21/2022
Objection raised — Other
04/11/2022
Filed — Alteration CO
Existing one family dwelling to be horizontally and vertically enlarged and converted into a two family dwellings. New drywall partitions ,and plumbing fixtures as per plans.
X00527244-P1
04/11/2022
Special inspection requirement — Fenestration air leakage
Rajasekhar Sakhamuri
04/11/2022
Special inspection requirement — Footing and Foundation
Rajasekhar Sakhamuri
04/11/2022
Special inspection requirement — Structural Wood Frame
Rajasekhar Sakhamuri
04/11/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
Rajasekhar Sakhamuri
04/11/2022
Special inspection requirement — Fenestration areas
Rajasekhar Sakhamuri
04/11/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
Rajasekhar Sakhamuri
04/11/2022
Special inspection requirement — Air barrier - visual inspection
Rajasekhar Sakhamuri
04/11/2022
Special inspection requirement — Interior lighting power
Rajasekhar Sakhamuri
04/11/2022
Special inspection requirement — Permanent certificate
Rajasekhar Sakhamuri
04/11/2022
Special inspection requirement — Insulation placement and R values
Rajasekhar Sakhamuri
04/11/2022
Special inspection requirement — Chimneys and vents
Rajasekhar Sakhamuri
04/11/2022
Special inspection requirement — Concrete - Cast-In-Place
Rajasekhar Sakhamuri
04/06/2022
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
03/29/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/11/2022
Signed off — Alteration
Installation of a temporary construction wood fence, for the renovation and conversion of one family dwelling into a two family dwelling ,filed in conjunction with A:LT CO app#X00527244-I1
X00637059-I1
03/08/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
03/07/2022
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
02/28/2022
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
01/25/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
01/25/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/08/2021
Permit issued — General Construction
X00527244-I1-GC-CX
11/30/2021
Permit issued — Construction Fence
X00637059-I1-FN
11/28/2021
Filed — Alteration
Installation of a temporary construction wood fence, for the renovation and conversion of one family dwelling into a two family dwelling ,filed in conjunction with A:LT CO app#X00527244-I1
X00637059-I1
09/16/2021
Permit issued — Plumbing
X00592250-I1-PL
09/14/2021
Filed — Alteration
Installation of new gas fired equipment and plumbing fixtures for the renovation and conversion of the existing one family dwelling into a two family dwellings. Filed in conjunction with ALT I application #X00527244
X00592250-I1
09/03/2021
Objection raised — Structural
09/03/2021
Objection resolved — Addressed
09/03/2021
Objection raised — Other
09/03/2021
Objection resolved — Addressed
09/03/2021
Objection raised — Inspections
09/03/2021
Objection resolved — Addressed
09/03/2021
Objection raised — Other
09/03/2021
Objection resolved — Addressed
09/03/2021
Objection raised — Other
09/03/2021
Objection resolved — Addressed
Latest 60 of 71 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedRASHBI DEVELOPMENT INC12/08/2021
DOB NOWConstruction FenceSigned-offRASHBI DEVELOPMENT INC11/30/2021
DOB NOWPlumbingSigned-offPLBG P & H INC09/16/2021
1 project · most recent 06/02/2022
General Wiring Lighting
FiledStatusContractorScope
06/02/2022CompleteBDS ELECTRIC CORP.General Wiring, Lighting
1 project · most recent 04/11/2022
Concrete Wood
FiledStatusContractorScope
04/11/2022Permit IssuedRASHBI DEVELOPMENT INCConcrete, Wood
▾Field Inspections (DOB CAP) — 10
DateTypeResultReport
05/03/2022Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
05/03/2022Pass-Final CND-Occupancy InspectionPassView ↗
04/21/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/06/2022Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
03/29/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/08/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
03/07/2022Pass-Final CND-Occupancy InspectionPassView ↗
02/28/2022Fail-Final CND-Occupancy InspectionFailView ↗
01/25/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
01/25/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 45
DateRequirementInspectorRole
04/29/2022Air barrier - visual inspectionRajasekhar Sakhamurienergy_progress
04/29/2022Chimneys and ventsRajasekhar Sakhamurispecial
04/29/2022Fire-Resistant Penetrations and JointsRajasekhar Sakhamurispecial
04/29/2022Concrete - Cast-In-PlaceRajasekhar Sakhamurispecial
04/29/2022Structural Stability – Alterations of existing buildingsRajasekhar Sakhamurispecial
04/29/2022Subgrade InspectionsRajasekhar Sakhamurispecial
04/29/2022Energy Code Compliance InspectionsRajasekhar Sakhamuriprogress
04/29/2022Fire-Resistance Rated ConstructionRajasekhar Sakhamuriprogress
04/29/2022Footing and FoundationRajasekhar Sakhamuriprogress
04/29/2022Structural Wood FrameRajasekhar Sakhamuriprogress
04/29/2022FinalRajasekhar Sakhamuriprogress
04/29/2022Insulation placement and R valuesRajasekhar Sakhamurienergy_progress
04/29/2022Permanent certificateRajasekhar Sakhamurienergy_progress
04/29/2022Fenestration and door U-factor and product ratingsRajasekhar Sakhamurienergy_progress
04/29/2022Fenestration air leakageRajasekhar Sakhamurienergy_progress
04/29/2022Interior lighting powerRajasekhar Sakhamurienergy_progress
04/29/2022HVAC-R and service water piping design and insulationRajasekhar Sakhamurienergy_progress
04/29/2022Fenestration areasRajasekhar Sakhamurienergy_progress
04/11/2022Fenestration air leakageRajasekhar Sakhamurienergy_progress
04/11/2022Footing and FoundationRajasekhar Sakhamuriprogress
04/11/2022Structural Wood FrameRajasekhar Sakhamuriprogress
04/11/2022Fenestration and door U-factor and product ratingsRajasekhar Sakhamurienergy_progress
04/11/2022Fenestration areasRajasekhar Sakhamurienergy_progress
04/11/2022HVAC-R and service water piping design and insulationRajasekhar Sakhamurienergy_progress
04/11/2022Air barrier - visual inspectionRajasekhar Sakhamurienergy_progress
Latest 25 of 45.
▾Documents — 74 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/25/2026X00592250-I1Request digital key ↗
08/25/2026X00637059-I1Request digital key ↗
08/15/2026X00527244-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZoning Exhibit form (1-5)2
08/13/2026X00527244-P1Open ↗
08/13/2026X00527244-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026X00527244-P1Open ↗
08/13/2026X00527244-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026X00527244-I1Open ↗
▸Seals & Professional Certifications50
▸DOB NOWProgress Inspector Seal & Signature32
08/31/2026X00637059-I1Open ↗
08/28/2026X00527244-I1Open ↗
08/28/2026X00527244-I1Open ↗
Showing 3 of 32 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature14
08/28/2026X00527244-I1Open ↗
08/28/2026X00527244-I1Open ↗
08/28/2026X00527244-I1Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/25/2026X00592250-I1Open ↗
08/24/2026X00527244-P1Open ↗
08/24/2026X00527244-I1Open ↗
Showing 3 of 4 on file for this type
▸Safety & Tenant Protection5
▸DOB NOWStreet Tree Checklist2
08/13/2026X00527244-P1Open ↗
08/13/2026X00527244-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026X00527244-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026X00527244-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026X00527244-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/25/2026X00592250-I1Open ↗
08/15/2026X00527244-I1Open ↗
08/14/2026X00527244-P1Open ↗
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis.2
08/13/2026X00592250-I1Open ↗
08/13/2026X00527244-I1Open ↗
▸Other Documents5
▸DOB NOWPlot Diagram2
08/13/2026X00527244-I1Open ↗
08/13/2026X00527244-P1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026X00527244-I1Open ↗
08/13/2026X00527244-P1Open ↗
▸DOB NOWFinal Survey1
08/13/2026X00527244-I1Open ↗