← Back
BuildNYC
Church, synagogue, chapel
285 VANDERBILT AVENUE
STATEN ISLAND · BIN 5014183
💬 Discuss this project
1931Year Built
1Stories
M1Building Class
R3AZoning
7,420 sfGross Floor Area
1Units
0 Active ViolationsFDNY Report ↗
Church, synagogue, chapel · Owner of record: The Vanderbilt Avenue Moravian Church · 21,250 sf lot · 0.35 FAR built · Flood zone X
Locations of Work
MechanicalPlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofVanderbilt Avenue Moravian Church2p · 1 filing · 12 docs
Site & exteriorVanderbilt Avenue Moravian Church2p · 1 filing · 12 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
YMCA of Greater New York603/21/2026
YMCA503/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Permanen Engineering International212/09/2019
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KAS103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Scaran Oil ServiceGeneral Contractor203/21/2026
High Beam ElectricElectrical103/21/2026
Scaran PlumbingPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Reliance Engineering322112/04/2019
Building Lifecycle
All (26)Filed (2)Permit Issued (2)Signed Off (1)Violation (15)Special Inspection (6)
12/12/2025
Violation issued (FDNY_ORDER, closed)
12/12/2025
Violation issued (FDNY_ORDER, closed)
09/23/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/30/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/30/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/25/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/19/2022
Violation issued (FDNY_NOV, closed)
03/05/2020
Signed off — Alteration
MECHANICAL WORK TYPE FILED FOR REPLACEMENT OF 2 HVAC UNIT AT ROOF AND OSP OF BUILDING ON EXISTING STEEL DUNNAGE CONNECTING TO EX. DUCT SYSTEM AND PIPING. NO CHANGE TO USE EGRESS AND/OR OCCUPANCY.PREVIOUSLY FILED UNDER APPLICATION 500521848
S00215723-S1
01/09/2020
Permit issued — Plumbing
S00215723-S1-PL
01/08/2020
Permit issued — Mechanical Systems
S00215723-I1-MS
12/09/2019
Filed — Alteration
MECHANICAL WORK TYPE FILED FOR REPLACEMENT OF 2 HVAC UNIT AT ROOF AND OSP OF BUILDING ON EXISTING STEEL DUNNAGE CONNECTING TO EX. DUCT SYSTEM AND PIPING. NO CHANGE TO USE EGRESS AND/OR OCCUPANCY.PREVIOUSLY FILED UNDER APPLICATION 500521848
S00215723-S1
12/09/2019
Special inspection requirement — Maintenance information
Ralph Giorgio
12/04/2019
Filed — Alteration
MECHANICAL WORK TYPE FILED FOR REPLACEMENT OF 2 HVAC UNIT AT ROOF AND OSP OF BUILDING ON EXISTING STEEL DUNNAGE CONNECTING TO EX. DUCT SYSTEM AND PIPING. NO CHANGE TO USE EGRESS AND/OR OCCUPANCY.PREVIOUSLY FILED UNDER APPLICATION 500521848
S00215723-I1
08/22/2019
Special inspection requirement — Mechanical Systems
Ralph Giorgio
08/22/2019
Special inspection requirement — Heating Systems
Ralph Giorgio
08/22/2019
Special inspection requirement — Final
Ralph Giorgio
08/22/2019
Special inspection requirement — HVAC insulation and sealing
Ralph Giorgio
08/22/2019
Special inspection requirement — Maintenance information
Ralph Giorgio
03/03/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/08/2010
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/22/2003
Violation issued (ECB, closed)
Construction
05/04/1998
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/29/1995
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/08/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offScaran Plumbing01/09/2020
DOB NOWMechanical SystemsSigned-offScaran Oil Service01/08/2020
BISOTISSUEDJoseph Rizzuti08/23/2012
BISPLISSUEDCharles J. Dehart JR P&H06/25/2002
BIS—ISSUEDAvid Construction06/24/2002
BISMHISSUEDAvid Construction06/24/2002
BISOTISSUEDAvid Construction06/17/2002
BIS—ISSUEDAvid Construction03/07/2002
BISEQISSUEDAvid Construction03/07/2002
BISMHISSUEDAvid Construction03/05/2002
1 project · most recent 12/09/2019
Air Conditioning Systems Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
12/09/2019Signed-offScaran Oil ServiceAir Conditioning Systems, Heating Systems
Cooling
Trane YHC072F3 120,000 BTU · Condensing Unit ×1
Heating
Trane TRA4YCC4060A 115,000 BTU · Condensing Unit ×1
1 project · most recent 12/09/2019
Gas
FiledStatusContractorScope
12/09/2019Signed-offScaran PlumbingGas
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
12/09/2019Maintenance informationRalph Giorgioenergy_progress
08/22/2019Mechanical SystemsRalph Giorgiospecial
08/22/2019Heating SystemsRalph Giorgiospecial
08/22/2019FinalRalph Giorgioprogress
08/22/2019HVAC insulation and sealing Ralph Giorgioenergy_progress
08/22/2019Maintenance informationRalph Giorgioenergy_progress
▾Tenants in the building
TenantSpaceFloorsRenovation projects
Vanderbilt Avenue Moravian ChurchReligiousRoof
Project S00215723 Alteration · Permit Entire · 12/04/2019
Names are taken automatically from the text of each project’s filed documents (title blocks and cover sheets) and screened to exclude owners, landlords and designers. They may be incomplete or wrong; check the filing.
▾Documents — 26 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch - Mechanical Systems1
08/26/2026S00215723-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing1
08/26/2026S00215723-S1Request digital key ↗
▸Applications & Permits3
▸BISPLAN / WORK APPROVAL APPLICATION2
05/21/2012520096477Open ↗
04/12/2012520096477Open ↗
▸BISWORK PERMIT APPLICATION1
08/23/2012520096477Open ↗
▸Seals & Professional Certifications11
▸DOB NOWProgress Inspector Seal & Signature4
09/02/2026S00215723-I1Open ↗
09/02/2026S00215723-I1Open ↗
09/02/2026S00215723-I1Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
09/26/2012520096477Open ↗
08/23/2012520096477Open ↗
04/12/2012520096477Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/02/2026S00215723-I1Open ↗
09/02/2026S00215723-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026S00215723-I1Open ↗
08/13/2026S00215723-S1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026S00215723-I1Open ↗
08/13/2026S00215723-S1Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
04/12/2012520096477Open ↗
▸Approvals, Objections & Sign-offs4
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter2
08/13/2026S00215723-I1Open ↗
08/13/2026S00215723-S1Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
04/12/2012520096477Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
09/26/2012520096477Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
09/26/2012520096477Open ↗
05/22/2012520096477Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
04/12/2012520096477Open ↗