← Back
Miscellaneous two family
286 22 STREET
BROOKLYN · BIN 3324922
💬 Discuss this project
1910Year Built
2Stories
B9Building Class
R6BZoning
992 sfGross Floor Area
2Units
2 Open Violations ▸
Miscellaneous two family · Owner of record: LOBUE HOUSING CORPORATION · 2,504 sf lot · 0.4 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
LOBUE HOUSING209/13/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/30/2018$400K—Private party → LOBUE HOUSING CORPORATION$403/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ABC ENGINEERING PLLC105/07/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
RACCOON CONSTRUCTION INCGeneral Contractor107/22/2026
Building Lifecycle
All (10)Filed (1)Permit Issued (1)Violation (3)Objection (2)Special Inspection (3)
07/20/2026
Permit issued — General Construction
B01394911-I1-GC
05/27/2026
Objection resolved — Addressed
05/12/2026
Objection raised — Scope
05/07/2026
Filed — Alteration
REPLACE EXISTING EXTERIOR FINISH AND WINDOWS AT EXP #1 & 2 TO RESOLVE ECB VIOLATION #39186161M. REPAIR EXIST. FRONT EXTERIOR TRAP DOOR. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B01394911-I1
04/29/2026
Special inspection requirement — Energy Code Compliance Inspections
HUI ZENG
04/29/2026
Special inspection requirement — Fenestration air leakage
HUI ZENG
04/29/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
HUI ZENG
04/27/2026
Violation issued (ECB, closed)
Unknown
04/27/2026
Violation issued (ECB, open)
Construction
04/27/2026
Violation issued (ECB, open)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedRACCOON CONSTRUCTION INC07/20/2026
1 project · most recent 04/28/2026
HVAC Wiring
FiledStatusContractorScope
04/28/2026Permit IssuedJKL ELECTRIC LLCHVAC Wiring
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
04/29/2026Energy Code Compliance InspectionsHUI ZENGprogress
04/29/2026Fenestration air leakageHUI ZENGenergy_progress
04/29/2026Fenestration and door U-factor and product ratingsHUI ZENGenergy_progress
▾Documents — 5 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/15/2026B01394911-I1Request digital key ↗
▸Seals & Professional Certifications3
▸DOB NOWProgress Inspector Seal & Signature2
08/31/2026B01394911-I1Open ↗
08/31/2026B01394911-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/17/2026B01394911-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/15/2026B01394911-I1Open ↗