← Back
BuildNYC
One story - permanent living quarter
287 RIDGECREST AVENUE
STATEN ISLAND · BIN 5066626
💬 Discuss this project
1960Year Built
1Stories
A2Building Class
R1-2Zoning
1,100 sfGross Floor Area
1Units
One story - permanent living quarter · 4,100 sf lot · 0.27 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Floor 25p · 1 filing · 20 docs
Floor 17p · 1 filing · 20 docs
Cellar7p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Madriaga Engineering311/20/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NY Building AssociatesGeneral Contractor203/21/2026
A Electrical Main ServiceElectrical103/22/2026
American Standard P&H CororpPlumbing107/08/2026
Venture Home SolarGeneral Contractor105/17/2017
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
J&R Design and Inspection6637311/20/2025
Building Lifecycle
04/02/2026
Signed off — Alteration
FILE PLUMBING WORK OF 1-FAMILY BUILDING WITH INSTALL NEW/REPLACE PLUMBING FIXTURES AND GAS APPLIANCES AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
S01281948-S1
04/02/2026
Signed off — Alteration
FILE PLUMBING WORK OF 1-FAMILY BUILDING WITH INSTALL NEW/REPLACE PLUMBING FIXTURES AND GAS APPLIANCES AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
S01281948-I1
03/19/2026
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
03/06/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
11/21/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Robert Truskosky
23 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offAmerican Standard P&H Cororp10/03/2025
DOB NOWGeneral ConstructionSigned-offNY Building Associates09/19/2025
BISOTISSUEDVenture Home Solar05/17/2017
1 project · most recent 10/01/2025
FiledStatusContractorScope
10/01/2025CompleteA Electrical Main Service—
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
03/19/2026Pass-Final General Construction Non-Directive 14PassView ↗
03/06/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
11/14/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
11/14/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/14/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 11
DateRequirementInspectorRole
11/21/2025Fire-Resistant Penetrations and JointsRobert Truskoskyspecial
11/21/2025Energy Code Compliance InspectionsRobert Truskoskyprogress
11/18/2025Fire-Resistant Penetrations and JointsRobert Truskoskyspecial
11/18/2025Energy Code Compliance InspectionsRobert Truskoskyprogress
09/11/2025Air barrier - visual inspectionRobert Truskoskyenergy_progress
09/11/2025Fire-Resistant Penetrations and JointsRobert Truskoskyspecial
09/11/2025Fenestration areasRobert Truskoskyenergy_progress
09/11/2025Fenestration air leakageRobert Truskoskyenergy_progress
09/11/2025Energy Code Compliance InspectionsRobert Truskoskyprogress
09/11/2025Fire-Resistance Rated ConstructionRobert Truskoskyprogress
09/11/2025Fenestration and door U-factor and product ratingsRobert Truskoskyenergy_progress
44 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account