← Back
Two family brick
29 MT MORRIS PARK WEST
MANHATTAN · BIN 1053402
💬 Discuss this project
1880Year Built
3Stories
B1Building Class
R7-2Zoning
3,060 sfGross Floor Area
2Units
Rent Stabilized0 Open Violations
Two family brick · 1,600 sf lot · 1.91 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Floor 316p · 1 filing · 20 docs
Floor 216p · 1 filing · 20 docs
Floor 116p · 1 filing · 20 docs
Cellar22p · 3 filings · 20 docs
Basement23p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/24/2020$2.6M—Private party → Private party$861/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
WILLIAM F. RYAN, JR. P.E. PC210/03/2024
MABBOTT SEIDEL ARCHITECTURE, PLLC1109/28/2022
VASILIOS ARTEMIOU PE203/28/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JENNY FLORES EXPEDITING1203/21/2026
MABBOTT SEIDEL BUILD203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MABBBOTT SEIDEL BUILD LLCGeneral Contractor507/08/2026
PATRICIA CAESAR THOMASElectrical103/21/2026
ORBIT SPRINKLER CORPFire Protection107/08/2026
AMN PLUMBING CORPPlumbing107/08/2026
ORBIT PLBG & HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
RYAN SPECIAL ENGINEERING2018110/03/2024
MABBOTT SEIDEL ARCHITECTU4475206/20/2022
MACIA INSPECTION & TESTIN402706/20/2022
Building Lifecycle
All (84)Filed (15)Permit Issued (6)Signed Off (4)Violation (17)Inspection (8)Objection (6)Special Inspection (28)
06/04/2025
Violation issued (HPD, closed)
A
02/10/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
11/22/2024
Violation issued (HPD, closed)
I
11/15/2024
Permit issued — Plumbing
M01110043-I1-PL
10/09/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
10/03/2024
Filed — Alteration
MODIFICATION TO EXISTING DOMESTIC WATER SERVICE AND PROPOSAL OF FIRESPRINKLER WATER SERVICE ONLY AT CELLAR WATER SERVICE AREA TO REFLECTNEW WATER SERVICE SIZE. NO WORK PERMIT REQUIRED.
M01110043-S1
10/02/2024
Special inspection requirement — Sprinkler Systems
William Ryan
10/01/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
09/17/2024
Filed — Alteration
MODIFICATION TO EXISTING DOMESTIC WATER SERVICE AND PROPOSAL OF FIRESPRINKLER WATER SERVICE ONLY AT CELLAR WATER SERVICE AREA TO REFLECTNEW WATER SERVICE SIZE. NO WORK PERMIT REQUIRED.
M01110043-I1
04/01/2024
Violation issued (HPD, closed)
A
11/15/2023
Violation issued (HPD, closed)
I
03/15/2023
Violation issued (HPD, closed)
A
11/16/2022
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
11/12/2022
Special inspection requirement — Mechanical Systems
DAVID MABBOTT
11/12/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
Jeffrey Stones
11/12/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
DAVID MABBOTT
11/12/2022
Special inspection requirement — Fire-Resistance Rated Construction
DAVID MABBOTT
11/12/2022
Special inspection requirement — Energy Code Compliance Inspections
DAVID MABBOTT
11/12/2022
Special inspection requirement — Final
DAVID MABBOTT
11/12/2022
Special inspection requirement — Masonry
Jeffrey Stones
11/12/2022
Special inspection requirement — Fenestration air leakage
DAVID MABBOTT
11/12/2022
Special inspection requirement — Lighting in dwelling units
DAVID MABBOTT
11/12/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
DAVID MABBOTT
11/12/2022
Special inspection requirement — Insulation placement and R values
DAVID MABBOTT
11/12/2022
Special inspection requirement — HVAC-R and service water heating equipment
DAVID MABBOTT
11/12/2022
Special inspection requirement — HVAC-R and service water heating system controls
DAVID MABBOTT
11/07/2022
Objection resolved — Addressed
11/02/2022
Violation issued (HPD, closed)
I
09/30/2022
Signed off — Alteration
HEREBY FILING FOR INSTALLATION AND RELOCATION OF PLUMBING FIXTURES. NO CHANGE TO USE OCCUPANCY OR EGRESS.
M00635700-I1
09/28/2022
Filed — Alteration
HEREBY FILING FOR INSTALLATION AND RELOCATION OF PLUMBING FIXTURES. NO CHANGE TO USE OCCUPANCY OR EGRESS.
M00635700-P4
08/09/2022
Signed off — Alteration
HEREBY FILING FOR THE INSTALLATION OF SPRINKLER HEADS. NO CHANGE TO USE OCCUPANCY OR EGRESS.
M00574049-I1
08/04/2022
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
08/01/2022
Filed — Alteration
HEREBY FILING FOR INSTALLATION AND RELOCATION OF PLUMBING FIXTURES. NO CHANGE TO USE OCCUPANCY OR EGRESS.
M00635700-P3
08/01/2022
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
07/28/2022
Signed off — Alteration
CONSTRUCTION FENCE
M00643948-I1
07/13/2022
Signed off — Alteration
HEREBY FILING FOR LIMITED INTERIOR AND EXTERIOR REMOVALS ANS CORRESPONDING STRUCTURAL WORK. NO CHANGE TO USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION
M00581849-I1
07/07/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
06/23/2022
Objection raised — Inspections
06/20/2022
Filed — Alteration CO
HEREBY FILING TO CONVERT SRO TO SINGLE FAMILY. INTERIOR RENOVATION. INSTALLATION OF MECHANCIAL EQUIPMENT.
M00493158-P1
05/05/2022
Filed — Alteration
HEREBY FILING FOR LIMITED INTERIOR AND EXTERIOR REMOVALS ANS CORRESPONDING STRUCTURAL WORK. NO CHANGE TO USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION
M00581849-P2
05/02/2022
Special inspection requirement — Structural Steel - High Strength Bolting
Jeffrey Stones
05/02/2022
Special inspection requirement — Final
DAVID MABBOTT
05/02/2022
Special inspection requirement — Masonry
Jeffrey Stones
05/02/2022
Special inspection requirement — Structural Cold-Formed Steel
Jeffrey Stones
05/02/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
Jeffrey Stones
05/02/2022
Special inspection requirement — Structural Steel - Welding
Jeffrey Stones
03/28/2022
Filed — Alteration
HEREBY FILING FOR THE INSTALLATION OF SPRINKLER HEADS. NO CHANGE TO USE OCCUPANCY OR EGRESS.
M00574049-P1
03/28/2022
Special inspection requirement — Sprinkler Systems
Jeffrey Stones
03/22/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/15/2022
Filed — Alteration
HEREBY FILING FOR INSTALLATION AND RELOCATION OF PLUMBING FIXTURES. NO CHANGE TO USE OCCUPANCY OR EGRESS.
M00635700-P2
03/07/2022
Filed — Alteration
HEREBY FILING FOR INSTALLATION AND RELOCATION OF PLUMBING FIXTURES. NO CHANGE TO USE OCCUPANCY OR EGRESS.
M00635700-P1
02/16/2022
Violation issued (HPD, closed)
A
02/16/2022
Violation issued (HPD, closed)
I
12/09/2021
Permit issued — Construction Fence
M00643948-I1-FN
12/08/2021
Filed — Alteration
CONSTRUCTION FENCE
M00643948-I1
12/08/2021
Special inspection requirement — Final
DAVID MABBOTT
12/04/2021
Permit issued — Plumbing
M00635700-I1-PL
11/24/2021
Permit issued — Mechanical Systems
M00493158-I1-GC-CX
11/23/2021
Filed — Alteration
HEREBY FILING FOR INSTALLATION AND RELOCATION OF PLUMBING FIXTURES. NO CHANGE TO USE OCCUPANCY OR EGRESS.
M00635700-I1
11/01/2021
Permit issued — Sprinklers
M00574049-I1-EW-SP
Latest 60 of 84 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offAMN PLUMBING CORP11/15/2024
DOB NOWConstruction FenceSigned-offMABBBOTT SEIDEL BUILD LLC12/09/2021
DOB NOWPlumbingSigned-offORBIT PLBG & HTG INC12/04/2021
DOB NOWMechanical SystemsPermit IssuedMABBBOTT SEIDEL BUILD LLC11/24/2021
DOB NOWSprinklersSigned-offORBIT SPRINKLER CORP11/01/2021
DOB NOWStructuralSigned-offMABBBOTT SEIDEL BUILD LLC09/08/2021
BISPLISSUEDWATSON'S PLBG, HTG, & BDG01/16/2018
1 project · most recent 06/20/2022
Air Conditioning Systems Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
06/20/2022Permit IssuedMABBBOTT SEIDEL BUILD LLCAir Conditioning Systems, Heating Systems
Cooling
Daikin FXSQ18TAVJU 18,000 BTU · Vrf Indoor ×2
FXTQ18TAVJUAAC 18,000 BTU · Vrf Indoor ×2
FXSQ07TAVJU 7,500 BTU · Vrf Indoor ×1
FXSQ12TAVJU 12,000 BTU · Vrf Indoor ×1
FXSQ24TAVJU 24,000 BTU · Vrf Indoor ×1
Heating
Daikin RXTQ60TAVJU 57,000 BTU · Vrf Outdoor ×2
1 project · most recent 10/03/2024
FiledStatusContractorScope
10/03/2024———
1 project · most recent 10/03/2024
Water/Sanitary
FiledStatusContractorScope
10/03/2024Signed-offAMN PLUMBING CORPWater/Sanitary
2 projects · most recent 11/04/2022
General Wiring
FiledStatusContractorScope
11/04/2022CompletePW & SONS ELECTRICAL CORPGeneral Wiring
12/06/2021CompletePW & SONS ELECTRICAL CORP—
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
02/10/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
10/09/2024Pass-Final CND-Occupancy InspectionPassView ↗
10/01/2024Pass-Final CND-Occupancy InspectionPassView ↗
11/16/2022Pass-Final CND-Occupancy InspectionPassView ↗
08/04/2022Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
08/01/2022Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
07/07/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/22/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 28
DateRequirementInspectorRole
10/02/2024Sprinkler SystemsWilliam Ryanspecial
11/12/2022Mechanical SystemsDAVID MABBOTTspecial
11/12/2022Structural Stability – Alterations of existing buildingsJeffrey Stonesspecial
11/12/2022Fire-Resistant Penetrations and JointsDAVID MABBOTTspecial
11/12/2022Fire-Resistance Rated ConstructionDAVID MABBOTTprogress
11/12/2022Energy Code Compliance InspectionsDAVID MABBOTTprogress
11/12/2022FinalDAVID MABBOTTprogress
11/12/2022MasonryJeffrey Stonesspecial
11/12/2022Fenestration air leakageDAVID MABBOTTenergy_progress
11/12/2022Lighting in dwelling unitsDAVID MABBOTTenergy_progress
11/12/2022Fenestration and door U-factor and product ratingsDAVID MABBOTTenergy_progress
11/12/2022Insulation placement and R valuesDAVID MABBOTTenergy_progress
11/12/2022HVAC-R and service water heating equipmentDAVID MABBOTTenergy_progress
11/12/2022HVAC-R and service water heating system controlsDAVID MABBOTTenergy_progress
05/02/2022Structural Steel - High Strength BoltingJeffrey Stonesspecial
05/02/2022FinalDAVID MABBOTTprogress
05/02/2022MasonryJeffrey Stonesspecial
05/02/2022Structural Cold-Formed SteelJeffrey Stonesspecial
05/02/2022Structural Stability – Alterations of existing buildingsJeffrey Stonesspecial
05/02/2022Structural Steel - WeldingJeffrey Stonesspecial
03/28/2022Sprinkler SystemsJeffrey Stonesspecial
12/08/2021FinalDAVID MABBOTTprogress
10/21/2021MasonryJeffrey Stonesspecial
10/21/2021Structural Cold-Formed SteelJeffrey Stonesspecial
10/21/2021Structural Stability – Alterations of existing buildingsJeffrey Stonesspecial
Latest 25 of 28.
▾Documents — 121 on file (BIS + DOB NOW)
▸Plans & Drawings15
▸DOB NOWPlans/Sketch15
09/03/2026M00643948-I1Request digital key ↗
09/02/2026M00635700-P1Request digital key ↗
09/02/2026M00635700-P2Request digital key ↗
Showing 3 of 15 on file for this type
▸Applications & Permits14
▸DOB NOWLPC Approval/Permit10
09/02/2026M00635700-P1Open ↗
09/02/2026M00635700-P2Open ↗
09/02/2026M00635700-P3Open ↗
Showing 3 of 10 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION3
01/22/2020123053300Open ↗
01/15/2020123053300Open ↗
04/12/2017123053300Open ↗
▸BISWORK PERMIT APPLICATION1
01/17/2018123053300Open ↗
▸Seals & Professional Certifications37
▸DOB NOWDPL-1: Design Professional Seal & Signature15
09/03/2026M00643948-I1Open ↗
09/02/2026M00635700-I1Open ↗
09/02/2026M00635700-P1Open ↗
Showing 3 of 15 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature15
09/01/2026M00581849-P1Open ↗
09/01/2026M00581849-P1Open ↗
09/01/2026M00581849-P1Open ↗
Showing 3 of 15 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
09/01/2026M00581849-P1Open ↗
08/30/2026M00581849-P2Open ↗
08/28/2026M00493158-I1Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
01/17/2018123053300Open ↗
▸Trade Schedules & Equipment2
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
04/27/2018123053300Open ↗
04/12/2017123053300Open ↗
▸Safety & Tenant Protection18
▸DOB NOWHPD-3: Single Room Occupancy Multiple Dwelling (SRO MD) Anti-Harassment Checklist12
09/03/2026M00643948-I1Open ↗
09/02/2026M00635700-I1Open ↗
09/02/2026M00635700-P1Open ↗
Showing 3 of 12 on file for this type
▸BISTenant Protection Plan and Notes3
11/27/2017123053300Open ↗
11/27/2017123053300Open ↗
10/19/2017123053300Open ↗
▸DOB NOWStreet Tree Checklist2
08/13/2026M00493158-I1Open ↗
08/13/2026M00493158-P1Open ↗
▸BISANTI-HARASSMENT CHECKLIST1
12/19/2017123053300Open ↗
▸Environmental & Asbestos15
▸DOB NOWDEP ACP-5: Asbestos Assessment Report14
09/02/2026M00635700-I1Open ↗
09/02/2026M00635700-P1Open ↗
09/02/2026M00635700-P2Open ↗
Showing 3 of 14 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
12/19/2017123053300Open ↗
▸Energy Compliance6
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
01/17/2018123053300Open ↗
12/19/2017123053300Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
05/24/2021123053300Open ↗
05/24/2021123053300Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
05/24/2021123053300Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026M00493158-I1Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
05/24/2021123053300Open ↗
05/24/2021123053300Open ↗
▸Approvals, Objections & Sign-offs2
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
05/24/2021123053300Open ↗
▸BISLANDMARKS APPROVAL1
12/19/2017123053300Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
05/24/2021123053300Open ↗
12/19/2017123053300Open ↗
04/12/2017123053300Open ↗
▸Filing & Intake Forms3
▸BISBOROUGH INTAKE FORM2
01/15/2020123053300Open ↗
04/27/2018123053300Open ↗
▸BISADDITIONAL INFORMATION1
05/16/2018123053300Open ↗
▸Other Documents4
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026M00493158-P1Open ↗
08/13/2026M00493158-I1Open ↗
▸DOB NOWPlot Diagram2
08/13/2026M00493158-P1Open ↗
08/13/2026M00493158-I1Open ↗