← Back
Four families
29 MT HOPE PLACE
BRONX · BIN 2008241
💬 Discuss this project
1901Year Built
3Stories
C3Building Class
R8Zoning
4,096 sfGross Floor Area
4Units
Rent Stabilized11 Open Violations ▸
Four families · Owner of record: MT EMANUEL HOPE PROPERTIES LLC · 3,125 sf lot · 1.31 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionCivil
Permit Issued — active, not yet Signed-off
RoofUnder Construction9p · 5 filings · 20 docs
Floor 15Under Construction9p · 3 filings · 20 docs
Floor 14Under Construction7p · 3 filings · 20 docs
Floor 13Under Construction7p · 3 filings · 20 docs
Floor 12Under Construction7p · 3 filings · 20 docs
Floor 11Under Construction7p · 3 filings · 20 docs
Floor 10Under Construction7p · 3 filings · 20 docs
Floor 9Under Construction45p · 3 filings · 20 docs
Floor 8Under Construction7p · 3 filings · 20 docs
Floor 7Under Construction7p · 3 filings · 20 docs
Floor 6Under Construction7p · 3 filings · 20 docs
Floor 5Under Construction28p · 3 filings · 20 docs
Floor 4Under Construction41p · 3 filings · 20 docs
Floor 3Under Construction41p · 3 filings · 20 docs
Floor 2Under Construction41p · 3 filings · 20 docs
Floor 1Under Construction7p · 3 filings · 20 docs
CellarUnder Construction45p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
OWNERS REP709/16/2026
BUILDHOUSER3409/15/2026
LEAD IT BUILDERS203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
VASILIOS ARTEMIOU PE608/19/2026
SONI ENGINEERING CONSULTING507/08/2026
ADROIT ENGINEERING PLLC111/11/2025
NIKOLAI KATZ ARCHITECT509/10/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EXPRESS FILING INC2003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CORE SCAFFOLD SYSTEMS INC.General Contractor609/16/2026
LEAD IT BUILDERS, LLCGeneral Contractor507/14/2026
TARGET PIPING NY LLCFire Protection307/08/2026
N TECH DESIGN OF AMERICAGeneral Contractor104/09/2026
B&B MECH PLBG & HTG LLCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF SERVICES CORP5616808/19/2026
Building Lifecycle
All (89)Filed (18)Permit Issued (17)Signed Off (1)Violation (18)Inspection (5)Special Inspection (30)
09/15/2026
Permit issued — Sidewalk Shed
X01419134-I1-SH
09/01/2026
Permit issued — Mechanical Systems
X01222960-S6-MS
09/01/2026
Inspection — Certified StandPipe - SD - Alarm Sys 64/09 - Finish
Certified
View inspection ↗
09/01/2026
Inspection — Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)
Certified
View inspection ↗
08/19/2026
Filed — New Building
SPRINKLER & STANDPIPE SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION X01222960-I1
X01222960-P2
08/13/2026
Special inspection requirement — Maintenance information
SHAHRIAR QUAYYUM
08/13/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
SHAHRIAR QUAYYUM
08/13/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
SHAHRIAR QUAYYUM
08/13/2026
Special inspection requirement — HVAC-R and service water heating equipment
SHAHRIAR QUAYYUM
08/13/2026
Special inspection requirement — HVAC-R and service water heating system controls
SHAHRIAR QUAYYUM
08/04/2026
Violation issued (ECB, closed)
Construction
08/04/2026
Violation issued (ECB, open)
Construction
08/04/2026
Violation issued (ECB, closed)
Construction
07/30/2026
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
07/13/2026
Permit issued — Structural
X01222960-S2-ST
07/09/2026
Permit issued — Protection and Mechanical Methods
X01427828-I1-PMM
07/09/2026
Permit issued — Supported Scaffold
X01427827-I1-SF
07/09/2026
Permit issued — Protection and Mechanical Methods
X01426800-I1-PMM
07/08/2026
Filed — Alteration
INSTALLATION OF TEMPORARY ROOF PROTECTION AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
X01426800-I1
07/08/2026
Filed — Alteration
INSTALLATION OF TEMPORARY PIPE SCAFFOLD & SYSTEM SCAFFOLD AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
X01427827-I1
07/08/2026
Filed — Alteration
INSTALLATION OF TEMPORARY ENGINEERED ENCLOSURE SYSTEM AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY
X01427828-I1
06/23/2026
Permit issued — Sidewalk Shed
X01419134-I1-SH
06/22/2026
Filed — Alteration
INSTALLATION OF TEMPORARY OVERHEAD PROTECTION AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
X01420180-I1
06/22/2026
Permit issued — Protection and Mechanical Methods
X01420180-I1-PMM
06/18/2026
Filed — Alteration
INSTALLATION OF TEMPORARY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
X01419134-I1
04/30/2026
Violation issued (HPD, open)
A
04/22/2026
Permit issued — Earth Work
X01222960-S3-FO-EA
04/15/2026
Permit issued — Support of Excavation
X01222960-S8-SE
04/15/2026
Permit issued — General Construction
X01222960-I1-GC
03/13/2026
Special inspection requirement — Subgrade Inspections
SHAHRIAR QUAYYUM
03/13/2026
Special inspection requirement — Structural Steel - Details
SHAHRIAR QUAYYUM
03/13/2026
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Bin Li
03/13/2026
Special inspection requirement — Construction Operations Influencing Adjacent Structures
SHAHRIAR QUAYYUM
03/13/2026
Special inspection requirement — Post-installed Anchors
SHAHRIAR QUAYYUM
03/13/2026
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
SHAHRIAR QUAYYUM
03/13/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
SHAHRIAR QUAYYUM
03/03/2026
Permit issued — Standpipe
X01222960-S5-EW-SD
03/03/2026
Permit issued — Standpipe
X01222960-S7-EW-SD
03/02/2026
Permit issued — Standpipe
X01222960-S5-EW-SP
03/02/2026
Permit issued — Plumbing
X01222960-S4-PL
02/24/2026
Inspection — Pass-Final SP - Up to 9 Requested Floors
Pass
View inspection ↗
01/17/2026
Signed off — Full Demolition
Full demolition to a two story house
X01251411-I1
12/30/2025
Permit issued — Full Demolition
X01251411-I1-FD
12/12/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
11/20/2025
Filed — New Building
SPRINKLER & STANDPIPE SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION X01222960-I1
X01222960-Z1
11/19/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
11/17/2025
Violation issued (HPD, open)
I
11/11/2025
Filed — Alteration
X01316529-I1
10/27/2025
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Bin Li
10/22/2025
Filed — Full Demolition
Full demolition to a two story house
X01251411-I1
09/10/2025
Filed — New Building
SPRINKLER & STANDPIPE SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION X01222960-I1
X01222960-S8
09/03/2025
Permit issued — Construction Fence
X01222960-S1-FN
08/29/2025
Filed — New Building
SPRINKLER & STANDPIPE SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION X01222960-I1
X01222960-S3
08/28/2025
Filed — New Building
SPRINKLER & STANDPIPE SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION X01222960-I1
X01222960-S2
08/28/2025
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
SHAHRIAR QUAYYUM
08/28/2025
Special inspection requirement — Construction Operations Influencing Adjacent Structures
SHAHRIAR QUAYYUM
08/28/2025
Special inspection requirement — Post-installed Anchors
SHAHRIAR QUAYYUM
08/28/2025
Special inspection requirement — Post-installed Anchors
SHAHRIAR QUAYYUM
08/28/2025
Special inspection requirement — Masonry
SHAHRIAR QUAYYUM
08/28/2025
Special inspection requirement — Subgrade Inspections
SHAHRIAR QUAYYUM
Latest 60 of 89 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSidewalk ShedPermit IssuedCORE SCAFFOLD SYSTEMS INC.09/15/2026
DOB NOWMechanical SystemsPermit IssuedLEAD IT BUILDERS, LLC09/01/2026
DOB NOWStructuralPermit IssuedLEAD IT BUILDERS, LLC07/13/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedCORE SCAFFOLD SYSTEMS INC.07/09/2026
DOB NOWSupported ScaffoldPermit IssuedCORE SCAFFOLD SYSTEMS INC.07/09/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedCORE SCAFFOLD SYSTEMS INC.07/09/2026
DOB NOWSidewalk ShedPermit IssuedCORE SCAFFOLD SYSTEMS INC.06/23/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedCORE SCAFFOLD SYSTEMS INC.06/22/2026
DOB NOWEarth WorkPermit IssuedLEAD IT BUILDERS, LLC04/22/2026
DOB NOWSupport of ExcavationPermit IssuedLEAD IT BUILDERS, LLC04/15/2026
DOB NOWGeneral ConstructionPermit IssuedLEAD IT BUILDERS, LLC04/15/2026
DOB NOWStandpipePermit IssuedTARGET PIPING NY LLC03/03/2026
DOB NOWStandpipePermit IssuedTARGET PIPING NY LLC03/03/2026
DOB NOWStandpipePermit IssuedTARGET PIPING NY LLC03/02/2026
DOB NOWPlumbingPermit IssuedTARGET PIPING NY LLC03/02/2026
DOB NOWFull DemolitionSigned-offN TECH DESIGN OF AMERICA12/30/2025
DOB NOWConstruction FencePermit IssuedLEAD IT BUILDERS, LLC09/03/2025
1 project · most recent 08/19/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
08/19/2026Permit IssuedTARGET PIPING NY LLCGas, Storm, Water/Sanitary
3 projects · most recent 09/22/2026
General Wiring
FiledStatusContractorScope
09/22/2026Permit IssuedPOWER DIRECT ELECTRIC INCGeneral Wiring
06/22/2026Permit IssuedSOLAS ELECTRICAL CORP—
12/16/2025Permit IssuedHIVOLTS ELECTRICAL INCGeneral Wiring
1 project · most recent 08/19/2026
Concrete
FiledStatusContractorScope
08/19/2026Permit IssuedLEAD IT BUILDERS, LLCConcrete
2 projects · most recent 07/08/2026
Scaffold Sidewalk Shed
FiledStatusContractorScope
07/08/2026Permit IssuedCORE SCAFFOLD SYSTEMS INCScaffold
06/18/2026Permit IssuedCORE SCAFFOLD SYSTEMS INCSidewalk Shed
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
09/01/2026Certified StandPipe - SD - Alarm Sys 64/09 - FinishCertifiedView ↗
09/01/2026Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)CertifiedView ↗
07/30/2026Pass-Final PL - UndergroundPassView ↗
02/24/2026Pass-Final SP - Up to 9 Requested FloorsPassView ↗
12/12/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 63
DateRequirementInspectorRole
08/13/2026Fire-Resistant Penetrations and JointsSHAHRIAR QUAYYUMspecial
08/13/2026HVAC-R and service water piping design and insulationSHAHRIAR QUAYYUMenergy_progress
08/13/2026Maintenance informationSHAHRIAR QUAYYUMenergy_progress
08/13/2026HVAC-R and service water heating equipmentSHAHRIAR QUAYYUMenergy_progress
08/13/2026HVAC-R and service water heating system controlsSHAHRIAR QUAYYUMenergy_progress
03/13/2026Excavations - Sheeting, Shoring, and BracingSHAHRIAR QUAYYUMspecial
03/13/2026Subsurface Conditions – Fill Placement & In-Place DensitySHAHRIAR QUAYYUMspecial
03/13/2026Subgrade InspectionsSHAHRIAR QUAYYUMspecial
03/13/2026Structural Steel - DetailsSHAHRIAR QUAYYUMspecial
03/13/2026Subsurface Investigations (Borings/Test Pits)Bin Lispecial
03/13/2026Post-installed AnchorsSHAHRIAR QUAYYUMspecial
03/13/2026Construction Operations Influencing Adjacent StructuresSHAHRIAR QUAYYUMspecial
11/19/2025Fire-Resistant Penetrations and Joints—special
10/27/2025Subsurface Investigations (Borings/Test Pits)Bin Lispecial
08/28/2025Post-installed AnchorsSHAHRIAR QUAYYUMspecial
08/28/2025Concrete - Cast-In-PlaceSHAHRIAR QUAYYUMspecial
08/28/2025Construction Operations Influencing Adjacent StructuresSHAHRIAR QUAYYUMspecial
08/28/2025MasonrySHAHRIAR QUAYYUMspecial
08/28/2025Subsurface Conditions – Fill Placement & In-Place DensitySHAHRIAR QUAYYUMspecial
08/28/2025Subgrade InspectionsSHAHRIAR QUAYYUMspecial
08/28/2025Post-installed AnchorsSHAHRIAR QUAYYUMspecial
08/28/2025Construction Operations Influencing Adjacent StructuresSHAHRIAR QUAYYUMspecial
08/28/2025Concrete - Cast-In-PlaceSHAHRIAR QUAYYUMspecial
08/26/2025HVAC-R and service water heating system controlsSHAHRIAR QUAYYUMenergy_progress
08/26/2025Fire-Resistant Penetrations and JointsSHAHRIAR QUAYYUMspecial
Latest 25 of 63.
▾Documents — 112 on file (BIS + DOB NOW)
▸Plans & Drawings19
▸DOB NOWPlans/Sketch19
08/18/2026X01222960-S8Request digital key ↗
08/18/2026X01222960-S7Request digital key ↗
08/18/2026X01222960-S6Request digital key ↗
Showing 3 of 19 on file for this type
▸Applications & Permits1
▸DOB NOWHPD - Permit Notice1
08/18/2026X01222960-I1Open ↗
▸Zoning, Tax Lot & Property Records21
▸DOB NOWRestrictive Declaration/Easement 28
08/18/2026X01222960-S8Open ↗
08/18/2026X01222960-S3Open ↗
08/18/2026X01222960-S2Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWRestrictive Declaration/Easement 18
08/18/2026X01222960-S8Open ↗
08/18/2026X01222960-S3Open ↗
08/18/2026X01222960-S2Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWZD1: DOB Zoning Diagram2
08/18/2026X01222960-I1Open ↗
08/18/2026X01222960-P1Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/18/2026X01222960-I1Open ↗
08/18/2026X01222960-P1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/18/2026X01222960-I1Open ↗
▸Seals & Professional Certifications42
▸DOB NOWDPL-1: Design Professional Seal & Signature18
08/18/2026X01222960-S7Open ↗
08/18/2026X01222960-S6Open ↗
08/18/2026X01222960-S5Open ↗
Showing 3 of 18 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature12
09/01/2026X01222960-S6Open ↗
08/31/2026X01222960-S8Open ↗
08/31/2026X01222960-S8Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWProgress Inspector Seal & Signature11
09/01/2026X01222960-S6Open ↗
09/01/2026X01222960-S6Open ↗
08/30/2026X01222960-P2Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWCONTRACTOR SEAL & SIGNATURE1
08/13/2026X01251411-I1Open ↗
▸Trade Schedules & Equipment6
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)1
08/18/2026X01222960-I1Open ↗
▸DOB NOWGas Cut-Off1
08/13/2026X01251411-I1Open ↗
▸DOB NOWElectric Cut-Off1
08/13/2026X01251411-I1Open ↗
▸DOB NOWWater Cut-Off1
08/13/2026X01251411-I1Open ↗
▸DOB NOWStandpipe Alarms Drawings1
08/18/2026X01222960-I1—
▸DOB NOWSewer Cut-Off1
08/13/2026X01251411-I1Open ↗
▸Safety & Tenant Protection5
▸DOB NOWHPD-3: Single Room Occupancy Multiple Dwelling (SRO MD) Anti-Harassment Checklist2
08/18/2026X01222960-I1Open ↗
08/18/2026X01222960-P1Open ↗
▸DOB NOWStreet Tree Checklist2
08/18/2026X01222960-I1Open ↗
08/18/2026X01222960-P1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/18/2026X01222960-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWRodent Control1
08/13/2026X01251411-I1Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026X01251411-I1Open ↗
▸Inspections & Test Reports4
▸DOB NOWTR4 Test Report and Plot Diagram2
08/18/2026X01222960-S8Open ↗
08/13/2026X01222960-S3Open ↗
▸DOB NOWSOIL REPORT2
08/18/2026X01222960-S8Open ↗
08/13/2026X01222960-S3Open ↗
▸Other Documents12
▸DOB NOWProperty Ownership Certification3
08/18/2026X01222960-I1Open ↗
08/18/2026X01222960-P1Open ↗
08/13/2026X01251411-I1Open ↗
▸DOB NOWSite Survey: Initial2
08/18/2026X01222960-I1Open ↗
08/18/2026X01222960-P1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/18/2026X01222960-I1Open ↗
08/18/2026X01222960-P1Open ↗
▸DOB NOWAdjoining Owners Notification2
08/18/2026X01222960-S3Open ↗
08/18/2026X01222960-S8Open ↗
▸DOB NOWStructure Photographs1
08/13/2026X01251411-I1Open ↗
▸DOB NOWFull Demo: 10-Day Notice1
08/13/2026X01251411-I1Open ↗
▸DOB NOWCommunity Board Notification1
08/13/2026X01251411-I1Open ↗