CUNY SC > LC_392_Lehman College
2900 GOULDEN AVENUE · Bedford Park · BIN 2098696
💬 Discuss this project
1930Year Built
4Stories
W5Building Class
R6Zoning
1,237,424 sfGross Floor Area
9Units
LL97 Covered2 Open Violations ▸FISP: No Report Filed
City university · Owner of record: DORMITORY AUTHORITY OF THE STATE OF NEW YORK · 925,614 sf lot · 1.34 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingEquipmentCivilGeneralOther
Roof29p · 3 filings · 20 docs
Cellar4p · 1 filing · 4 docs
Basement1p · 1 filing · 4 docs
Site & exterior16p · 3 filings · 9 docs
Filed — no permit issued38p · 1 filing · 4 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
DASNY3807/08/2026
CUNY DPT OF DESIGN CONS MGMT1303/21/2026
DORMITORY AUTHORITY STATE OF NEW1103/21/2026
DORMITORY AUTHORITY OF THE STATE503/21/2026
DORMITORY AUTH THE STATE OF NY403/21/2026
DORMITORY203/21/2026
DORMITORY AUTH. STATE OF NY103/21/2026
MASTER FIRE PREVENTION SYSTEMS103/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
MERRITT ENGINEERING CONSULTANT DPC2603/21/2026
AK CONSULTING SERVICES603/21/2026
SUPERSTRUCTURES ENG + ARCH103/21/2026
BURNHAM NATIONWIDE INC103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
P B CONTRACTING CORPGeneral Contractor1407/08/2026
CUBE CONST SERVICES LLCGeneral Contractor303/21/2026
AMH MECHANICAL INCGeneral Contractor104/09/2026
BOYD MECHANICAL LLCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
UNIVERSAL TESTING AND INS400812/09/2025
IKRA CONSULTING LLC7032110/15/2024
TECTONIC ENGINEERING CONS106104/20/2021
Building Lifecycle
All (86)Filed (19)Permit Issued (11)Signed Off (4)Facade (FISP) (3)Violation (8)Inspection (8)Objection (14)Special Inspection (19)
07/31/2026
Signed off — Alteration
REPLACE/MODIFY EXISTING DUCTWORK TO ACCOMODATE ROOF COVER REPLACEMEN APPLICATION FILED UNDER DOBNOW APPLICATION X0061855-I1. NO CHANGE IN USE, OCCUPANCY OR EGRESS
X00693059-I1
07/30/2026
Signed off — Alteration
REMOVE EXISTING SBS MODIFIED ROOF COVER & ALL ASSOCIATED EQUIPMENT & PENETRATION FLASHINGS, INSTALL NEW SBS MODIFIED (3 PLY) SYSTEM. REPLACE/MODIFY EXISTING DUCTWORK TO ACCOMODATE ROOF COVER REPLACEMENT . NO CHANGE IN USE OCCUPANCY OR EGRESS.
X00661855-I1
07/27/2026
Signed off — Alteration
REPLACEMENT OF EXISTING ROOF DRAINS. INSTALL NEW ROOF DRAINS AND NEW OVERFLOW ROOF DRAINS. REPLACE 160 FEET OF 2" GAS PIPING. DISONNECT AND RECONNECT GAS BOOSTER PUMP AS PER PLANS SUBMITTED HEREWITH. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
X00661847-I1
03/19/2026
Filed — Alteration
REPLACEMENT OF EXISTING ROOF DRAINS. INSTALL NEW ROOF DRAINS AND NEW OVERFLOW ROOF DRAINS. REPLACE 160 FEET OF 2" GAS PIPING. DISONNECT AND RECONNECT GAS BOOSTER PUMP AS PER PLANS SUBMITTED HEREWITH. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
X00661847-P5
02/05/2026
Special inspection requirement — Masonry
NELSON LOPEZ
02/05/2026
Special inspection requirement — Energy Code Compliance Inspections
NELSON LOPEZ
02/05/2026
Special inspection requirement — Final
Christopher Krepcio
02/05/2026
Special inspection requirement — Insulation placement and R values
NELSON LOPEZ
02/05/2026
Special inspection requirement — Air barrier - visual inspection
NELSON LOPEZ
01/29/2026
Objection resolved — Addressed
01/28/2026
Objection raised — Scope
01/13/2026
Objection resolved — Addressed
12/30/2025
Objection resolved — Addressed
12/26/2025
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
12/24/2025
Objection raised — Scope
12/24/2025
Objection raised — Admin
12/09/2025
Filed — Alteration
REMOVE EXISTING SBS MODIFIED ROOF COVER & ALL ASSOCIATED EQUIPMENT & PENETRATION FLASHINGS, INSTALL NEW SBS MODIFIED (3 PLY) SYSTEM. REPLACE/MODIFY EXISTING DUCTWORK TO ACCOMODATE ROOF COVER REPLACEMENT . NO CHANGE IN USE OCCUPANCY OR EGRESS.
X00661855-P4
12/09/2025
Filed — Alteration
REPLACEMENT OF EXISTING ROOF DRAINS. INSTALL NEW ROOF DRAINS AND NEW OVERFLOW ROOF DRAINS. REPLACE 160 FEET OF 2" GAS PIPING. DISONNECT AND RECONNECT GAS BOOSTER PUMP AS PER PLANS SUBMITTED HEREWITH. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
X00661847-P4
12/04/2025
Special inspection requirement — Insulation placement and R values
NELSON LOPEZ
12/04/2025
Special inspection requirement — Masonry
NELSON LOPEZ
12/04/2025
Special inspection requirement — Energy Code Compliance Inspections
NELSON LOPEZ
12/04/2025
Special inspection requirement — Final
Christopher Krepcio
12/04/2025
Special inspection requirement — Air barrier - visual inspection
NELSON LOPEZ
12/03/2025
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
10/30/2025
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
09/26/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/10/2025
Special inspection requirement — Energy Code Compliance Inspections
NELSON LOPEZ
09/10/2025
Special inspection requirement — Final
Christopher Krepcio
09/10/2025
Special inspection requirement — Maintenance information
NELSON LOPEZ
09/10/2025
Special inspection requirement — Mechanical Systems
NELSON LOPEZ
09/09/2025
Objection resolved — Addressed
09/04/2025
Inspection — No Access-Final PL - Up to 3 Requested Floors
No Access
View inspection ↗
08/29/2025
Objection raised — Admin
08/25/2025
Filed — Alteration
REPLACE/MODIFY EXISTING DUCTWORK TO ACCOMODATE ROOF COVER REPLACEMEN APPLICATION FILED UNDER DOBNOW APPLICATION X0061855-I1. NO CHANGE IN USE, OCCUPANCY OR EGRESS
X00693059-P4
08/25/2025
Filed — Alteration
REPLACEMENT OF EXISTING ROOF DRAINS. INSTALL NEW ROOF DRAINS AND NEW OVERFLOW ROOF DRAINS. REPLACE 160 FEET OF 2" GAS PIPING. DISONNECT AND RECONNECT GAS BOOSTER PUMP AS PER PLANS SUBMITTED HEREWITH. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
X00661847-P3
08/22/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
08/11/2025
Filed — Alteration
REPLACEMENT OF EXISTING ROOF DRAINS. INSTALL NEW ROOF DRAINS AND NEW OVERFLOW ROOF DRAINS. REPLACE 160 FEET OF 2" GAS PIPING. DISONNECT AND RECONNECT GAS BOOSTER PUMP AS PER PLANS SUBMITTED HEREWITH. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
X00661847-P2
08/11/2025
Filed — Alteration
REPLACE/MODIFY EXISTING DUCTWORK TO ACCOMODATE ROOF COVER REPLACEMEN APPLICATION FILED UNDER DOBNOW APPLICATION X0061855-I1. NO CHANGE IN USE, OCCUPANCY OR EGRESS
X00693059-P3
08/11/2025
Filed — Alteration
REMOVE EXISTING SBS MODIFIED ROOF COVER & ALL ASSOCIATED EQUIPMENT & PENETRATION FLASHINGS, INSTALL NEW SBS MODIFIED (3 PLY) SYSTEM. REPLACE/MODIFY EXISTING DUCTWORK TO ACCOMODATE ROOF COVER REPLACEMENT . NO CHANGE IN USE OCCUPANCY OR EGRESS.
X00661855-P3
08/05/2025
Special inspection requirement — Energy Code Compliance Inspections
NELSON LOPEZ
08/05/2025
Special inspection requirement — Mechanical Systems
NELSON LOPEZ
08/05/2025
Special inspection requirement — Final
Christopher Krepcio
08/05/2025
Special inspection requirement — Maintenance information
08/05/2025
Special inspection requirement — Duct leakage testing, insulation and design
07/29/2025
Permit issued — Mechanical Systems
X00693059-I1-MS
07/28/2025
Permit issued — Sidewalk Shed
X01117567-I1-SH
07/28/2025
Permit issued — Construction Fence
X01117548-I1-FN
07/28/2025
Permit issued — Plumbing
X00661847-I1-PL
07/28/2025
Permit issued — General Construction
X00661855-I1-GC
07/28/2025
Permit issued — Supported Scaffold
X01117565-I1-SF
06/24/2025
Objection resolved — Addressed
06/24/2025
Objection resolved — Addressed
06/24/2025
Objection resolved — Addressed
06/06/2025
Filed — Alteration
REPLACE/MODIFY EXISTING DUCTWORK TO ACCOMODATE ROOF COVER REPLACEMEN APPLICATION FILED UNDER DOBNOW APPLICATION X0061855-I1. NO CHANGE IN USE, OCCUPANCY OR EGRESS
X00693059-P2
06/05/2025
Filed — Alteration
REPLACEMENT OF EXISTING ROOF DRAINS. INSTALL NEW ROOF DRAINS AND NEW OVERFLOW ROOF DRAINS. REPLACE 160 FEET OF 2" GAS PIPING. DISONNECT AND RECONNECT GAS BOOSTER PUMP AS PER PLANS SUBMITTED HEREWITH. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
X00661847-P1
06/05/2025
Objection raised — Scope
06/05/2025
Objection raised — Admin
06/05/2025
Objection raised — Scope
05/19/2025
Filed — Alteration
REMOVE EXISTING SBS MODIFIED ROOF COVER & ALL ASSOCIATED EQUIPMENT & PENETRATION FLASHINGS, INSTALL NEW SBS MODIFIED (3 PLY) SYSTEM. REPLACE/MODIFY EXISTING DUCTWORK TO ACCOMODATE ROOF COVER REPLACEMENT . NO CHANGE IN USE OCCUPANCY OR EGRESS.
X00661855-P2
04/01/2025
Inspection — Pass-Final SP - Up to 3 Requested Floors
Pass
View inspection ↗
Latest 60 of 86 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offAMH MECHANICAL07/29/2025
DOB NOWSidewalk ShedPermit IssuedP B CONTRACTING CORP07/28/2025
DOB NOWConstruction FencePermit IssuedP B CONTRACTING CORP07/28/2025
DOB NOWPlumbingSigned-offBOYD MECHANICAL LLC07/28/2025
DOB NOWGeneral ConstructionSigned-offP B CONTRACTING CORP07/28/2025
DOB NOWSupported ScaffoldPermit IssuedP B CONTRACTING CORP07/28/2025
DOB NOWSupported ScaffoldPermit IssuedP B CONTRACTING CORP10/17/2024
DOB NOWConstruction FencePermit IssuedP B CONTRACTING CORP10/16/2024
DOB NOWSidewalk ShedPermit IssuedP B CONTRACTING CORP10/16/2024
DOB NOWGeneral ConstructionSigned-offP B CONTRACTING CORP09/12/2024
DOB NOWStructuralSigned-offCUBE CONST SERVICES LLC05/11/2021
BISOTISSUEDMINELLI CONSTRUCTION CO01/17/2018
BISOTISSUEDMINELLI CONSTRUCTION CO12/20/2017
BISPLISSUEDDELPHI PLBG. & HTG., INC12/08/2017
BISEQISSUEDMINELLI CONSTRUCTION CO I05/05/2017
BISEQISSUEDMINELLI CONSTRUCTION CO I05/03/2017
BISEQISSUEDMINELLI CONSTRUCTION CO I05/03/2017
BISOTISSUEDMINELLI CONSTRUCTION CO I12/20/2016
BISOTISSUEDSBLM ARCHITECTS10/27/2016
BISOTISSUEDMINELLI CONSTRUCTION CO I07/22/2016
BISEQISSUEDMINELLI CONSTRUCTION CO I04/29/2016
BISEQISSUEDMINELLI CONSTRUCTION CO I04/14/2016
BISEQISSUEDMINELLI CONSTRUCTION CO I04/14/2016
BISPLISSUEDDELPHI PLBG. & HTG., INC08/10/2015
BISPLISSUEDDONATO INC08/07/2014
BISPLISSUEDDONATO INC04/15/2013
BISFPISSUEDMASTER FIRE SYSTEMS, INC08/01/2012
BISOTISSUEDMANHATTAN BUSINESS INTERIORS05/10/2012
BISOTISSUEDMANHATTAN BUSINESS INTERIORS05/10/2012
BISMHISSUEDMANHATTAN BUSINESS INTERIORS05/10/2012
BISPLISSUEDDONATO INC04/20/2012
BISOTISSUEDMANHATTAN BUSINESS INTERIORS04/11/2012
BISMHISSUEDMANHATTAN BUSINESS INTERIORS04/11/2012
BISOTISSUEDMANHATTAN BUSINESS INTERIORS04/11/2012
BISMHISSUEDMARIC PLUMBING & HEATING08/05/2010
BISOTISSUEDRICK'S CONSTRUCTION & IRON WORKS10/14/2008
BISOTISSUEDEXCEL INTERIOR CONSTRUCTION08/24/2008
BISOTISSUEDEXCEL INTERIOR CONSTRUCTION08/24/2008
BISEQISSUEDCISCO GENERAL CONSTRUCTION10/01/2007
BISEQISSUEDMSS CONSTRUCTION CORP08/10/2007
+ 11 more permits on file
1 project · most recent 08/25/2025
Associated Ducts and Piping
FiledStatusContractorScopeMake / Model / Capacity
08/25/2025Signed-offAMH MECHANICAL INCAssociated Ducts and Piping
Ducts & Piping
1 project · most recent 03/19/2026
Gas Storm
FiledStatusContractorScope
03/19/2026Signed-offBOYD MECHANICAL LLCGas, Storm
2 projects · most recent 10/15/2024
Sidewalk Shed Scaffold
FiledStatusContractorScope
10/15/2024Permit IssuedP B CONTRACTING CORPSidewalk Shed
10/15/2024Permit IssuedP B CONTRACTING CORPScaffold
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
12/26/2025Fail-Final PL - Up to 3 Requested FloorsFailView ↗
12/03/2025Fail-Final PL - Up to 3 Requested FloorsFailView ↗
10/30/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
09/26/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/04/2025No Access-Final PL - Up to 3 Requested FloorsNo AccessView ↗
08/22/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
04/01/2025Pass-Final SP - Up to 3 Requested FloorsPassView ↗
03/18/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 19
DateRequirementInspectorRole
02/05/2026MasonryNELSON LOPEZspecial
02/05/2026Energy Code Compliance InspectionsNELSON LOPEZprogress
02/05/2026FinalChristopher Krepcioprogress
02/05/2026Insulation placement and R valuesNELSON LOPEZenergy_progress
02/05/2026Air barrier - visual inspectionNELSON LOPEZenergy_progress
12/04/2025Insulation placement and R valuesNELSON LOPEZenergy_progress
12/04/2025MasonryNELSON LOPEZspecial
12/04/2025Energy Code Compliance InspectionsNELSON LOPEZprogress
12/04/2025FinalChristopher Krepcioprogress
12/04/2025Air barrier - visual inspectionNELSON LOPEZenergy_progress
09/10/2025Energy Code Compliance InspectionsNELSON LOPEZprogress
09/10/2025FinalChristopher Krepcioprogress
09/10/2025Maintenance informationNELSON LOPEZenergy_progress
09/10/2025Mechanical SystemsNELSON LOPEZspecial
08/05/2025Energy Code Compliance InspectionsNELSON LOPEZprogress
08/05/2025Mechanical SystemsNELSON LOPEZspecial
08/05/2025FinalChristopher Krepcioprogress
08/05/2025Maintenance information—energy_progress
08/05/2025Duct leakage testing, insulation and design—energy_progress
▾Documents — 342 on file (BIS + DOB NOW)
▸Plans & Drawings19
▸DOB NOWPlans/Sketch19
08/25/2026X00503727-I1Request digital key ↗
08/21/2026X00996576-I1Request digital key ↗
08/20/2026X01117565-I1Request digital key ↗
Showing 3 of 19 on file for this type
▸Applications & Permits64
▸BISPLAN / WORK APPROVAL APPLICATION38
01/28/2020240099576Open ↗
12/05/2019240099576Open ↗
03/05/2019240099576Open ↗
Showing 3 of 38 on file for this type
▸BISWORK PERMIT APPLICATION24
01/18/2018220429873Open ↗
12/26/2017220429873Open ↗
12/08/2017240099576Open ↗
Showing 3 of 24 on file for this type
▸BISPLACE OF ASSEMBLY2
01/24/2017220563986Open ↗
01/24/2017220563922Open ↗
▸Seals & Professional Certifications90
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION29
03/23/2020240099576Open ↗
04/26/2019220429873Open ↗
04/16/2019220429873Open ↗
Showing 3 of 29 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature19
08/25/2026X00503727-I1Open ↗
08/21/2026X00996576-I1Open ↗
08/20/2026X01117567-I1Open ↗
Showing 3 of 19 on file for this type
▸DOB NOWProgress Inspector Seal & Signature13
09/19/2026X00693059-P3Open ↗
09/19/2026X00693059-P3Open ↗
08/31/2026X00661855-I1Open ↗
Showing 3 of 13 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST6
07/28/2015240099576Open ↗
07/31/2012220210073Open ↗
Showing 2 of 6 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM5
07/31/2012220210073Open ↗
07/12/2011220125656Open ↗
Showing 2 of 5 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY5
04/28/2016240140414Open ↗
04/13/2016240138999Open ↗
04/13/2016240138980Open ↗
Showing 3 of 5 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION4
04/28/2016240140414Open ↗
04/13/2016240138999Open ↗
04/13/2016240138980Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT4
04/28/2016240140414Open ↗
04/13/2016240138999Open ↗
04/13/2016240138980Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/19/2026X00693059-P3Open ↗
08/31/2026X00661855-I1Open ↗
08/25/2026X00693059-I1Open ↗
Showing 3 of 4 on file for this type
▸BISPC FULL REPORT1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Trade Schedules & Equipment32
▸BISSELF-CERT PLUMBING NOTICE9
12/03/2014220139375Open ↗
11/28/2014220139375Open ↗
11/19/2014220139375Open ↗
Showing 3 of 9 on file for this type
▸BISSCHEDULE B - PLUMBING9
07/13/2015240099576Open ↗
01/02/2013220245544Open ↗
01/02/2013220245562Open ↗
Showing 3 of 9 on file for this type
▸BISPLUMBING - SUPPORTING DOCUMENTATION6
12/08/2014220139375Open ↗
11/19/2014220139375Open ↗
11/19/2014220139375Open ↗
Showing 3 of 6 on file for this type
▸BISFA - FDNY APPROVAL : FD-FAA5
11/19/2014220139375Open ↗
10/14/2014220139375Open ↗
10/14/2014220139375Open ↗
Showing 3 of 5 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE3
01/28/2020240099576Open ↗
03/05/2019240099576Open ↗
07/28/2015240099576Open ↗
▸Environmental & Asbestos23
▸BISDEP ASBESTOS PROJECT COMPLETION FORM8
04/16/2019220429873Open ↗
04/16/2019220429873Open ↗
04/16/2019220429873Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form3
08/18/2026X00661855-I1Open ↗
08/18/2026X00693059-I1Open ↗
08/17/2026X00661847-I1Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISDEP FORM V5 - ASBESTOS VARIANCE2
07/12/2011220125656Open ↗
Showing 1 of 2 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
04/28/2016240140414Open ↗
07/13/2015240099576Open ↗
▸BISASBESTOS INSPECTION REPORT2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/25/2026X00503727-I1Open ↗
08/21/2026X00996576-I1Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISASBESTOS: COMPLETION OR CLOSEOUT (ACP20/21/5)1
07/22/2016220429873Open ↗
▸Energy Compliance9
▸BISTECHNICAL REPORT: ENERGY4
04/13/2012220139375Open ↗
09/15/2011220139375Open ↗
Showing 2 of 4 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
04/16/2019220429873Open ↗
05/28/2015220429873Open ↗
▸DOB NOWEN2: As Built Energy Analysis2
08/18/2026X00661855-I1Open ↗
08/18/2026X00693059-I1Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
04/16/2019220429873Open ↗
▸Inspections & Test Reports4
▸BISHYDRAULIC FLOW CALCULATIONS2
01/08/2013220245562Open ↗
01/02/2013220245562Open ↗
▸BISHYDRO FLOW TEST LETTER1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY1
07/13/2015240099576Open ↗
▸Approvals, Objections & Sign-offs50
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter19
08/25/2026X00503727-I1Open ↗
08/21/2026X00996576-I1Open ↗
08/18/2026X00693059-P3Open ↗
Showing 3 of 19 on file for this type
▸BISADMINISTRATIVE OBJECTIONS12
01/02/2013220245544Open ↗
12/28/2012220245562Open ↗
07/31/2012220210073Open ↗
Showing 3 of 12 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST7
03/23/2020240099576Open ↗
04/26/2019220429873Open ↗
04/16/2019220429873Open ↗
Showing 3 of 7 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION4
03/03/2014220210073Open ↗
07/12/2011220125656Open ↗
Showing 2 of 4 on file for this type
▸BISSUPERSEDING LETTER4
12/26/2017220429873Open ↗
05/05/2017240138999Open ↗
05/03/2017240138980Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDEP Variance (V5) letter3
08/18/2026X00693059-I1Open ↗
08/13/2026X00661847-I1Open ↗
08/13/2026X00661855-I1Open ↗
▸BISSHED LETTER1
05/05/2017240138999Open ↗
▸Cost, Insurance & Ownership15
▸BISCOST AFFIDAVIT15
03/23/2020240099576Open ↗
04/16/2019220429873Open ↗
07/13/2015240099576Open ↗
Showing 3 of 15 on file for this type
▸Filing & Intake Forms30
▸BISEFILING COVER SHEET16
06/20/2016220537220Open ↗
05/28/2015220429873Open ↗
01/02/2013220245544Open ↗
Showing 3 of 16 on file for this type
▸BISADDITIONAL INFORMATION5
09/15/2015240099576Open ↗
07/25/2012220139375Open ↗
07/23/2012220139375Open ↗
Showing 3 of 5 on file for this type
▸BISBOROUGH INTAKE FORM5
03/23/2020240099576Open ↗
01/23/2020240099576Open ↗
04/26/2019220429873Open ↗
Showing 3 of 5 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET4
04/28/2016240140414Open ↗
04/13/2016240138999Open ↗
04/13/2016240138980Open ↗
Showing 3 of 4 on file for this type
▸Other Documents6
▸BISOP-129 INTERNAL (SECONDARY) BACKFLOW PREVENTION DEVICE TEST REPORT5
11/28/2014220139375Open ↗
11/28/2014220139375Open ↗
10/14/2014220139375Open ↗
Showing 3 of 5 on file for this type
▸BISINTERNAL (SECONDARY) BACKFLOW PREVENTION DEVICE TEST REPORT1
10/14/2014220139375Open ↗