← Back
Two family frame
291 ALTER AVENUE
STATEN ISLAND · BIN 5174866
💬 Discuss this project
2021Year Built
2Stories
B2Building Class
R3XZoning
2,410 sfGross Floor Area
2Units
Two family frame · 4,042 sf lot · 0.6 FAR built · Flood zone X500
Locations of Work
Architecture
Floor 11p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
291 ALTER AVE LLC703/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ROGERS CALVANICO GROUP PLLC204/05/2022
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DELTAMER, INCGeneral Contractor203/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
A TECH ENGINEERING NYC, P6738204/05/2022
Building Lifecycle
All (25)Filed (2)Permit Issued (1)Inspection (2)Special Inspection (20)
04/26/2022
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/20/2022
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
anthony santoro
04/20/2022
Special inspection requirement — Concrete - Cast-In-Place
anthony santoro
04/20/2022
Special inspection requirement — Subgrade Inspections
anthony santoro
04/20/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
anthony santoro
04/20/2022
Special inspection requirement — Fire-Resistance Rated Construction
anthony santoro
04/20/2022
Special inspection requirement — Structural Wood Frame
anthony santoro
04/20/2022
Special inspection requirement — Energy Code Compliance Inspections
anthony santoro
04/20/2022
Special inspection requirement — Final
anthony santoro
04/20/2022
Special inspection requirement — Footing and Foundation
anthony santoro
04/20/2022
Special inspection requirement — Interior lighting power
anthony santoro
04/05/2022
Filed — New Building
CONSTRUCT DETACHED ONE CAR GARAGE FOR NEW DWELLING UNIT (FILED UNDER APPLICATION S00515592)
S00518595-P1
04/04/2022
Special inspection requirement — Concrete - Cast-In-Place
anthony santoro
04/04/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
anthony santoro
04/04/2022
Special inspection requirement — Subgrade Inspections
anthony santoro
04/04/2022
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
anthony santoro
04/04/2022
Special inspection requirement — Energy Code Compliance Inspections
anthony santoro
04/04/2022
Special inspection requirement — Final
anthony santoro
04/04/2022
Special inspection requirement — Fire-Resistance Rated Construction
anthony santoro
04/04/2022
Special inspection requirement — Footing and Foundation
anthony santoro
04/04/2022
Special inspection requirement — Structural Wood Frame
anthony santoro
04/04/2022
Special inspection requirement — Interior lighting power
anthony santoro
03/09/2022
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
07/16/2021
Permit issued — General Construction
S00518595-I1-GC-CX
05/26/2021
Filed — New Building
CONSTRUCT DETACHED ONE CAR GARAGE FOR NEW DWELLING UNIT (FILED UNDER APPLICATION S00515592)
S00518595-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedDELTAMER, INC07/16/2021
1 project · most recent 03/03/2022
General Wiring
FiledStatusContractorScope
03/03/2022CompleteA & R ELEC'L CONTR'G INC.General Wiring
1 project · most recent 04/05/2022
Wood
FiledStatusContractorScope
04/05/2022Permit IssuedDELTAMER, INCWood
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
04/26/2022Pass-Final CND-Occupancy InspectionPassView ↗
03/09/2022Fail-Final CND-Occupancy InspectionFailView ↗
▾Special Inspection Requirements (DOB NOW) — 20
DateRequirementInspectorRole
04/20/2022Subsurface Investigations (Borings/Test Pits)anthony santorospecial
04/20/2022Concrete - Cast-In-Placeanthony santorospecial
04/20/2022Subgrade Inspectionsanthony santorospecial
04/20/2022Fire-Resistant Penetrations and Jointsanthony santorospecial
04/20/2022Fire-Resistance Rated Constructionanthony santoroprogress
04/20/2022Structural Wood Frameanthony santoroprogress
04/20/2022Energy Code Compliance Inspectionsanthony santoroprogress
04/20/2022Finalanthony santoroprogress
04/20/2022Footing and Foundationanthony santoroprogress
04/20/2022Interior lighting poweranthony santoroenergy_progress
04/04/2022Concrete - Cast-In-Placeanthony santorospecial
04/04/2022Fire-Resistant Penetrations and Jointsanthony santorospecial
04/04/2022Subgrade Inspectionsanthony santorospecial
04/04/2022Subsurface Investigations (Borings/Test Pits)anthony santorospecial
04/04/2022Energy Code Compliance Inspectionsanthony santoroprogress
04/04/2022Finalanthony santoroprogress
04/04/2022Fire-Resistance Rated Constructionanthony santoroprogress
04/04/2022Footing and Foundationanthony santoroprogress
04/04/2022Structural Wood Frameanthony santoroprogress
04/04/2022Interior lighting poweranthony santoroenergy_progress
▾Documents — 30 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/24/2026S00518595-I1Request digital key ↗
08/24/2026S00518595-P1Request digital key ↗
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026S00518595-I1Open ↗
08/13/2026S00518595-P1Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/13/2026S00518595-I1Open ↗
08/13/2026S00518595-P1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026S00518595-I1Open ↗
▸Seals & Professional Certifications10
▸DOB NOWProgress Inspector Seal & Signature4
08/31/2026S00518595-P1Open ↗
08/31/2026S00518595-P1Open ↗
08/26/2026S00518595-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/31/2026S00518595-P1Open ↗
08/31/2026S00518595-P1Open ↗
08/26/2026S00518595-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/24/2026S00518595-I1Open ↗
08/24/2026S00518595-P1Open ↗
▸Trade Schedules & Equipment3
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/13/2026S00518595-I1Open ↗
08/13/2026S00518595-P1Open ↗
▸DOB NOWStandpipe Alarms Drawings1
08/13/2026S00518595-I1—
▸Safety & Tenant Protection2
▸DOB NOWStreet Tree Sign Off1
08/13/2026S00518595-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026S00518595-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026S00518595-I1Open ↗
▸Inspections & Test Reports4
▸DOB NOWSOIL REPORT2
08/13/2026S00518595-I1Open ↗
08/13/2026S00518595-P1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/13/2026S00518595-I1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026S00518595-I1Open ↗
▸Other Documents3
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026S00518595-P1Open ↗
08/13/2026S00518595-I1Open ↗
▸DOB NOWFinal Survey1
08/13/2026S00518595-I1Open ↗