← Back
Two family brick
291 EAST 51 STREET
BROOKLYN · East Flatbush-Rugby · BIN 3101456
💬 Discuss this project
1920Year Built
2Stories
B1Building Class
R6Zoning
2,400 sfGross Floor Area
2Units
Two family brick · 2,533 sf lot · 0.95 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 22p · 1 filing · 11 docs
Floor 12p · 1 filing · 11 docs
Cellar4p · 1 filing · 11 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
GARFINKEL ARCHITECT, PLLC211/30/2023
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TUR CONTRACTING INCGeneral Contractor107/08/2026
DPH PLUMBING & HTG CORPPlumbing107/08/2026
Building Lifecycle
All (23)Filed (2)Permit Issued (2)Signed Off (2)Inspection (3)Special Inspection (14)
06/11/2025
Signed off — Alteration
Plumbing application filed
B00947704-I1
06/26/2024
Signed off — Alteration
Plumbing application filed
B00947704-S1
04/17/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
04/17/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/13/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/12/2023
Permit issued — Plumbing
B00947704-S1-PL
11/30/2023
Filed — Alteration
Plumbing application filed
B00947704-S1
11/30/2023
Special inspection requirement — HVAC-R and service water heating system controls
LEWIS GARFINKEL
11/30/2023
Special inspection requirement — HVAC-R and service water heating equipment
LEWIS GARFINKEL
11/30/2023
Special inspection requirement — Energy Code Compliance Inspections
LEWIS GARFINKEL
11/09/2023
Permit issued — General Construction
B00947704-I1-GC
11/01/2023
Filed — Alteration
Plumbing application filed
B00947704-I1
11/01/2023
Special inspection requirement — Metering
IGOR LISOVENKO
11/01/2023
Special inspection requirement — Air barrier - visual inspection
IGOR LISOVENKO
11/01/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
IGOR LISOVENKO
11/01/2023
Special inspection requirement — Fenestration areas
IGOR LISOVENKO
11/01/2023
Special inspection requirement — Insulation placement and R values
IGOR LISOVENKO
11/01/2023
Special inspection requirement — Fenestration air leakage
IGOR LISOVENKO
11/01/2023
Special inspection requirement — Interior lighting power
IGOR LISOVENKO
11/01/2023
Special inspection requirement — Permanent certificate
IGOR LISOVENKO
11/01/2023
Special inspection requirement — Energy Code Compliance Inspections
IGOR LISOVENKO
11/01/2023
Special inspection requirement — Fire-Resistance Rated Construction
IGOR LISOVENKO
10/13/2023
Special inspection requirement — Final
IGOR LISOVENKO
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offDPH PLUMBING & HTG CORP12/12/2023
DOB NOWGeneral ConstructionSigned-offTUR CONTRACTING INC11/09/2023
2 projects · most recent 04/11/2025
General Wiring
FiledStatusContractorScope
04/11/2025CompleteOLLIS ELECTRIC INCGeneral Wiring
12/12/2023CompleteFOSTER ELEC'L SVC., INC.General Wiring
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
04/17/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/17/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/13/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 14
DateRequirementInspectorRole
11/30/2023HVAC-R and service water heating system controlsLEWIS GARFINKELenergy_progress
11/30/2023HVAC-R and service water heating equipmentLEWIS GARFINKELenergy_progress
11/30/2023Energy Code Compliance InspectionsLEWIS GARFINKELprogress
11/01/2023MeteringIGOR LISOVENKOenergy_progress
11/01/2023Air barrier - visual inspectionIGOR LISOVENKOenergy_progress
11/01/2023Fenestration and door U-factor and product ratingsIGOR LISOVENKOenergy_progress
11/01/2023Fenestration areasIGOR LISOVENKOenergy_progress
11/01/2023Insulation placement and R valuesIGOR LISOVENKOenergy_progress
11/01/2023Fenestration air leakageIGOR LISOVENKOenergy_progress
11/01/2023Interior lighting powerIGOR LISOVENKOenergy_progress
11/01/2023Permanent certificateIGOR LISOVENKOenergy_progress
11/01/2023Energy Code Compliance InspectionsIGOR LISOVENKOprogress
11/01/2023Fire-Resistance Rated ConstructionIGOR LISOVENKOprogress
10/13/2023FinalIGOR LISOVENKOprogress
▾Documents — 11 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/26/2026B00947704-I1Request digital key ↗
08/26/2026B00947704-S1Request digital key ↗
▸Seals & Professional Certifications7
▸DOB NOWProgress Inspector Seal & Signature5
09/12/2026B00947704-I1Open ↗
09/12/2026B00947704-I1Open ↗
09/01/2026B00947704-S1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/26/2026B00947704-S1Open ↗
08/26/2026B00947704-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/26/2026B00947704-S1Open ↗
08/26/2026B00947704-I1Open ↗