← Back
Three families
291 WYTHE AVENUE
BROOKLYN · BIN 3062898
💬 Discuss this project
1910Year Built
3Stories
C0Building Class
R6Zoning
3,348 sfGross Floor Area
3Units
Rent StabilizedFDNY Report ↗
Three families · Owner of record: 347 BLEECKER LLC · 1,560 sf lot · 2.15 FAR built · Flood zone X
Locations of Work
ArchitectureStructural
Roof7p · 1 filing · 9 docs
Floor 22p · 1 filing · 6 docs
Floor 18p · 1 filing · 9 docs
Cellar2p · 1 filing · 6 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
347 BLEECKER LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/22/2024$3.7M—— → —$1,101/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FOCUS STRUCTURAL ENGINEERING102/27/2026
LAWRENCE MAREK ARCHITECT109/16/2025
CHERICO KING ARCHITECT, P.C.205/21/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CHERICO KING ARCHITECT P.C.403/21/2026
CHERICO KING ARCHITECT P C C403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NYC BUILDERS & RENOVATIONGeneral Contractor308/25/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CHERICO KING ARCHITECT PC5674302/27/2026
INTEGRITY CONSULTING SERV666102/27/2026
Building Lifecycle
All (45)Filed (4)Permit Issued (3)Objection (27)Special Inspection (11)
08/24/2026
Permit issued — Structural
B01343945-I1-ST
02/27/2026
Filed — Alteration
STRUCTURAL REPAIR TO EXISTING BUILDING FIRST FLOOR FRAMING, REPLACEMENT OF CORRODED WINDOW LINTELS AT GROUND FLOOR AND REINFORCEMENT OF EXISTING FIRST FLOOR TERRACE FRAMING. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01343945-I1
01/08/2026
Special inspection requirement — Preliminary
ALEKSANDR LEVIN
01/08/2026
Special inspection requirement — Tenant Protection Plan Compliance
LAWRENCE MAREK
01/08/2026
Special inspection requirement — Structural Steel - Details
ALEKSANDR LEVIN
01/08/2026
Special inspection requirement — Masonry
ALEKSANDR LEVIN
01/08/2026
Special inspection requirement — Post-installed Anchors
ALEKSANDR LEVIN
01/08/2026
Special inspection requirement — Post-installed anchors in masonry
ALEKSANDR LEVIN
01/08/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
ALEKSANDR LEVIN
01/08/2026
Special inspection requirement — Structural Steel - High Strength Bolting
ALEKSANDR LEVIN
01/08/2026
Special inspection requirement — Structural Steel - Welding
ALEKSANDR LEVIN
01/08/2026
Special inspection requirement — Final
ALEKSANDR LEVIN
09/24/2025
Permit issued — General Construction
B01168939-I1-GC-CX
09/19/2025
Permit issued — Construction Fence
B01168939-S2-FN
09/16/2025
Filed — Alteration
RENOVATE EXISTING RESTAURANT ON 1ST FLOOR AS PER CO# 100493. INSTALL MINOR PARTITIONS, BATHROOMS, KITCHEN EQUIPMENT, KITCHEN EXHAUST SYSTEM, & HVAC SYSTEM. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01168939-S2
06/16/2025
Objection resolved — Addressed
06/06/2025
Objection raised — Cost
06/06/2025
Objection resolved — Addressed
06/02/2025
Objection resolved — Addressed
05/23/2025
Objection raised — Scope
05/21/2025
Filed — Alteration
RENOVATE EXISTING RESTAURANT ON 1ST FLOOR AS PER CO# 100493. INSTALL MINOR PARTITIONS, BATHROOMS, KITCHEN EQUIPMENT, KITCHEN EXHAUST SYSTEM, & HVAC SYSTEM. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01168939-S1
05/15/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Cherico King
05/12/2025
Objection resolved — Addressed
05/12/2025
Objection resolved — Addressed
04/29/2025
Objection resolved — Addressed
04/04/2025
Objection raised — Other
04/04/2025
Objection resolved — Addressed
04/04/2025
Objection resolved — Addressed
03/24/2025
Objection resolved — Addressed
03/24/2025
Objection resolved — Addressed
03/24/2025
Objection resolved — Addressed
03/24/2025
Objection resolved — Addressed
03/24/2025
Objection resolved — Addressed
03/12/2025
Objection raised — Scope
03/12/2025
Objection raised — Scope
03/12/2025
Objection raised — Fire_Protection
03/12/2025
Objection raised — Accessibility
03/12/2025
Objection raised — Structural
03/12/2025
Objection raised — Inspections
03/12/2025
Objection raised — Other
03/12/2025
Objection raised — Admin
03/12/2025
Objection raised — Structural
03/12/2025
Objection raised — Fire_Protection
03/12/2025
Objection raised — Structural
03/05/2025
Filed — Alteration
RENOVATE EXISTING RESTAURANT ON 1ST FLOOR AS PER CO# 100493. INSTALL MINOR PARTITIONS, BATHROOMS, KITCHEN EQUIPMENT, KITCHEN EXHAUST SYSTEM, & HVAC SYSTEM. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01168939-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offNYC BUILDERS & RENOVATION08/24/2026
DOB NOWGeneral ConstructionPermit IssuedNYC BUILDERS & RENOVATION09/24/2025
DOB NOWConstruction FencePermit IssuedNYC BUILDERS & RENOVATION09/19/2025
1 project · most recent 09/16/2025
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
09/16/2025Permit IssuedNYC BUILDERS & RENOVATIONHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MODEL# MXZ-SM60NAM 120,000 BTU · Heat Pump Outdoor ×2
Ventilation
__Junk__ CUSTOM MAKE & SIZE 1,800 CFM · Kitchen Exhaust ×1
1 project · most recent 09/16/2025
Gas Water/Sanitary
FiledStatusContractorScope
09/16/2025——Gas, Water/Sanitary
2 projects · most recent 09/21/2026
General Wiring
FiledStatusContractorScope
09/21/2026Permit IssuedE & M ELECTRICAL NY CORPGeneral Wiring
12/03/2025Permit IssuedKET ELECTRIC LLCGeneral Wiring
1 project · most recent 02/27/2026
Steel
FiledStatusContractorScope
02/27/2026Signed-offNYC BUILDERS & RENOVATIONSteel
1 project · most recent 09/16/2025
Fence
FiledStatusContractorScope
09/16/2025Permit IssuedNYC BUILDERS & RENOVATIONFence
▾Special Inspection Requirements (DOB NOW) — 11
DateRequirementInspectorRole
01/08/2026PreliminaryALEKSANDR LEVINprogress
01/08/2026Tenant Protection Plan ComplianceLAWRENCE MAREKspecial
01/08/2026Structural Steel - DetailsALEKSANDR LEVINspecial
01/08/2026MasonryALEKSANDR LEVINspecial
01/08/2026Post-installed AnchorsALEKSANDR LEVINspecial
01/08/2026Post-installed anchors in masonryALEKSANDR LEVINspecial
01/08/2026Structural Stability – Alterations of existing buildingsALEKSANDR LEVINspecial
01/08/2026Structural Steel - High Strength BoltingALEKSANDR LEVINspecial
01/08/2026Structural Steel - WeldingALEKSANDR LEVINspecial
01/08/2026FinalALEKSANDR LEVINprogress
05/15/2025Fire-Resistant Penetrations and JointsCherico Kingspecial
▾Documents — 15 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/20/2026B01168939-S2Request digital key ↗
08/15/2026B01168939-S1Request digital key ↗
08/15/2026B01168939-I1Request digital key ↗
▸Seals & Professional Certifications9
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/20/2026B01168939-I1Open ↗
08/20/2026B01168939-S1Open ↗
08/20/2026B01168939-S2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/29/2026B01343945-I1Open ↗
08/29/2026B01343945-I1Open ↗
08/29/2026B01168939-S1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature1
08/29/2026B01343945-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/15/2026B01168939-S1Open ↗
08/15/2026B01168939-I1Open ↗
08/13/2026B01343945-I1Open ↗