← Back
Office with commercial, 1-6 stories
294 NEW DORP LANE
STATEN ISLAND · BIN 5152150
💬 Discuss this project
2004Year Built
3Stories
O5Building Class
R3-2Zoning
6,300 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Office with commercial, 1-6 stories · Owner of record: CS4 HOLDING LLC · 2,000 sf lot · 3.15 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectrical
Roof6p · 2 filings · 8 docs
Floor 36p · 1 filing · 11 docs
Floor 26p · 1 filing · 11 docs
Floor 113p · 3 filings · 16 docs
Cellar6p · 2 filings · 14 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
CS4 HOLDING LLC1503/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JAMES H. FAHEY301/22/2025
A & T ENGINEERING, P.C.603/09/2023
ALLEN SHINFELD, P.E. PLLC112/19/2022
JIAN ENGINEERING PLLC107/12/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
S Y CONSULTING VIOLATIONS1003/21/2026
CONSTRUCTION PERMIT SERVICES303/21/2026
YOUN DESIGN CORP203/21/2026
RYAN DESIGN ARCHITECTURE103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NORTH JERSEY ATMS LLCGeneral Contractor407/08/2026
DLC DEVELOPMENT CORPGeneral Contractor407/08/2026
P L ELECL CONTRG CORP 003654General Contractor203/22/2026
PETER LIElectrical203/21/2026
JOHN BUZZELLElectrical203/21/2026
NEPTUNE SIGNS AWNINGSScaffold107/08/2026
P.L. ELEC'L CONTR'G CORPElectrical103/22/2026
STATCON DEVELOPMENT LLCGeneral Contractor107/08/2026
NEW YORK STANDARD MECH CORPPlumbing107/08/2026
CITYWIDE ELECTRICAL SVCSElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
STRUCTURAL CONSULTING SER1919205/15/2024
A & T DESIGN GROUP LLC1088303/09/2023
RYAN DESIGN ARCHITECTURE7159107/12/2022
Building Lifecycle
All (45)Filed (11)Permit Issued (7)Signed Off (4)Violation (8)Inspection (6)Special Inspection (9)
06/17/2025
Signed off — Alteration
Installation of guard rails, access hatch, access ladder and metal cage partition panel. Relocation of access gate and grab bar. Removal of guard rails, access hatch and access ladder. No change in use, egress or occupancy.
S00454232-I1
01/28/2025
Permit issued — General Construction
S00454232-I1-GC
01/22/2025
Filed — Alteration
Installation of guard rails, access hatch, access ladder and metal cage partition panel. Relocation of access gate and grab bar. Removal of guard rails, access hatch and access ladder. No change in use, egress or occupancy.
S00454232-I1
08/12/2024
Signed off — Alteration
New VERIZON site. Install 3 sectors (9 antenna), 9 RRHs, 3 distribution boxes, 2 GPS units, & 1 equipment platform with cabinets and modified guardrail on the roof. Related conduits in cellar.
S00454215-I1
05/15/2024
Filed — Alteration
New VERIZON site. Install 3 sectors (9 antenna), 9 RRHs, 3 distribution boxes, 2 GPS units, & 1 equipment platform with cabinets and modified guardrail on the roof. Related conduits in cellar.
S00454215-P1
07/27/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/07/2023
Signed off — Alteration
plumbing work for drinking eating establishment
S00789498-I1
03/22/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
ROBERT LIN
03/13/2023
Signed off — Alteration
S08055412-I1
03/09/2023
Filed — Alteration
plumbing work for drinking eating establishment
S00789498-P2
03/09/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
ROBERT LIN
03/04/2023
Inspection — Pass-Final Sign Permit Inspection
Pass
View inspection ↗
03/01/2023
Permit issued — Antenna
S00454215-I1-AN
03/01/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
02/27/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
02/15/2023
Special inspection requirement — Interior lighting power
ROBERT LIN
02/15/2023
Special inspection requirement — Lighting controls
ROBERT LIN
02/01/2023
Filed — Alteration CO
PROPOSED TO RENOVATE EXISTING 1ST FLOOR AND CELLAR TO ESTABLISH EATING & DRINKING ESTABLISHMENT (UG 6). OBTAIN NEW CERTIFICATE OF OCCUPANCY
S00785883-P1
02/01/2023
Filed — Alteration
plumbing work for drinking eating establishment
S00789498-P1
02/01/2023
Special inspection requirement — Interior lighting power
ROBERT LIN
02/01/2023
Special inspection requirement — Lighting controls
ROBERT LIN
01/27/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
ROBERT LIN
01/19/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/17/2023
Permit issued — Sign
S08055412-I1-SG
12/19/2022
Filed — Alteration
S08055412-I1
11/23/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/03/2022
Permit issued — General Construction
S00785883-I1-GC
11/01/2022
Permit issued — Plumbing
S00789498-I1-PL
09/06/2022
Filed — Alteration
New VERIZON site. Install 3 sectors (9 antenna), 9 RRHs, 3 distribution boxes, 2 GPS units, & 1 equipment platform with cabinets and modified guardrail on the roof. Related conduits in cellar.
S00454215-I1
08/29/2022
Permit issued — General Construction
S00799190-I1-GC
08/24/2022
Filed — Alteration
PROPOSED TO RENOVATE EXISTING 1ST FLOOR AND CELLAR, RELOCATE PATITION WALL. NO CHANGE IN USE, OCUPPANCY, AND EGRESS.
S00799190-I1
08/24/2022
Permit issued — General Construction
S00760765-I1-GC
08/24/2022
Special inspection requirement — Final
ROBERT LIN
08/17/2022
Filed — Alteration
plumbing work for drinking eating establishment
S00789498-I1
08/04/2022
Filed — Alteration CO
PROPOSED TO RENOVATE EXISTING 1ST FLOOR AND CELLAR TO ESTABLISH EATING & DRINKING ESTABLISHMENT (UG 6). OBTAIN NEW CERTIFICATE OF OCCUPANCY
S00785883-I1
07/12/2022
Filed — Alteration
S00760765-I1
01/14/2021
Special inspection requirement — Final
James Fahey
11/08/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
10/27/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
11/01/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
12/23/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
08/05/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
09/17/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
09/08/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
10/01/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offNORTH JERSEY ATMS LLC01/28/2025
DOB NOWAntennaSigned-offNORTH JERSEY ATMS LLC03/01/2023
DOB NOWSignSigned-offNEPTUNE SIGNS&AWNINGS INC01/17/2023
DOB NOWGeneral ConstructionPermit IssuedDLC DEVELOPMENT CORP11/03/2022
DOB NOWPlumbingSigned-offNEW YORK STANDARD MECH CORP11/01/2022
DOB NOWGeneral ConstructionPermit IssuedDLC DEVELOPMENT CORP08/29/2022
DOB NOWGeneral ConstructionPermit IssuedSTATCON DEVELOPMENT LLC08/24/2022
BISMHISSUEDHAPPY GARDEN CONSTR. CORP09/17/2010
BIS—ISSUEDNCDC INC07/14/2010
BISPLISSUEDSO PLUMBING & HEATING INC09/03/2009
BISOTISSUEDMATASSA CONSTRUCTION INC04/15/2009
BISPLISSUEDDUO PLUMBING & HTG CORP.04/14/2009
BISMHISSUEDKEYSPAN PLBG SOLUTIONS INC12/06/2004
BIS—ISSUEDGIUSEPPE'S HOME IMPROVEMENT06/23/2004
BISEQISSUEDGIUSEPPE'S HOME IMPROVEMENT06/23/2004
BISPLISSUEDCRC MECH PLBG & HTG CORP04/30/2004
BISEQISSUEDGIUSEPPE'S HOME IMPROVEMENT04/07/2004
BISEQISSUEDPEAK SCAFFOLDING LLC10/01/2003
BISEQISSUEDGIUSEPPE'S HOME IMPROVEMENT09/29/2003
BIS—ISSUEDGIUSEPPE'S HOME IMPROVEMENT09/29/2003
3 projects · most recent 11/10/2023
General Wiring
FiledStatusContractorScope
11/10/2023CompleteCITYWIDE ELECTRICAL SVCSGeneral Wiring
04/26/2023CompleteP.L. ELEC'L CONTR'G CORPGeneral Wiring
12/16/2022CompleteJONG HYUN KIM—
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
07/27/2023Pass-Final CND-Occupancy InspectionPassView ↗
03/04/2023Pass-Final Sign Permit InspectionPassView ↗
03/01/2023Pass-Final CND-Occupancy InspectionPassView ↗
02/27/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/19/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
11/23/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
03/22/2023Fire-Resistant Penetrations and JointsROBERT LINspecial
03/09/2023Fire-Resistant Penetrations and JointsROBERT LINspecial
02/15/2023Interior lighting powerROBERT LINenergy_progress
02/15/2023Lighting controlsROBERT LINenergy_progress
02/01/2023Interior lighting powerROBERT LINenergy_progress
02/01/2023Lighting controlsROBERT LINenergy_progress
01/27/2023Fire-Resistant Penetrations and JointsROBERT LINspecial
08/24/2022FinalROBERT LINprogress
01/14/2021FinalJames Faheyprogress
▾Documents — 100 on file (BIS + DOB NOW)
▸Plans & Drawings11
▸DOB NOWPlans/Sketch8
08/24/2026S00760765-I1Request digital key ↗
08/24/2026S00799190-I1Request digital key ↗
08/23/2026S08055412-I1Request digital key ↗
Showing 3 of 8 on file for this type
▸DOB NOWPlans/Sketch - Antenna2
08/24/2026S00454215-P1Request digital key ↗
08/24/2026S00454215-I1Request digital key ↗
▸DOB NOWPlans/Sketch - General Construction1
08/20/2026S00454232-I1Request digital key ↗
▸Applications & Permits17
▸BISPLAN / WORK APPROVAL APPLICATION9
10/09/2013520126168Open ↗
09/19/2013520126168Open ↗
03/26/2013520126168Open ↗
Showing 3 of 9 on file for this type
▸BISWORK PERMIT APPLICATION6
09/17/2010520012049Open ↗
07/14/2010520036648Open ↗
09/03/2009520012049Open ↗
Showing 3 of 6 on file for this type
▸BISNon-Directive 14 Construction Sign Off Including Sign Applications1
12/29/2010520012049Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
10/01/2010520036648Open ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026S00785883-I1Open ↗
▸Seals & Professional Certifications24
▸DOB NOWDPL-1: Design Professional Seal & Signature11
08/23/2026S00789498-P1Open ↗
08/23/2026S00789498-I1Open ↗
08/20/2026S00454232-I1Open ↗
Showing 3 of 11 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION6
09/19/2013520126168Open ↗
12/28/2010520012049Open ↗
05/13/2010520036648Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
08/30/2026S00799190-I1Open ↗
08/30/2026S00454232-I1Open ↗
08/27/2026S00785883-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
08/29/2026S00789498-P2Open ↗
08/27/2026S00789498-P1Open ↗
08/23/2026S00789498-I1Open ↗
▸Trade Schedules & Equipment12
▸BISSCHEDULE B - PLUMBING5
03/26/2013520126168Open ↗
03/02/2010520012049Open ↗
01/29/2010520012049Open ↗
Showing 3 of 5 on file for this type
▸BISEQUIPMENT USE APPLICATION/PERMIT3
01/11/2011520012049Open ↗
03/01/2010520012049Open ↗
07/09/2009520012049Open ↗
▸BISSELF-CERT PLUMBING NOTICE3
02/01/2010520012049Open ↗
01/27/2010520012049Open ↗
06/25/2009510066848Open ↗
▸BISEQUIPMENT USE PERMITS1
01/11/2011520012049Open ↗
▸Safety & Tenant Protection2
▸BISSTREET TREE CHECKLIST2
10/04/2013520126168Open ↗
05/13/2010520036648Open ↗
▸Environmental & Asbestos3
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER3
05/13/2010520036648Open ↗
07/09/2009520012049Open ↗
02/17/2009510066848Open ↗
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis2
08/13/2026S00785883-I1Open ↗
08/13/2026S00454215-I1Open ↗
▸Approvals, Objections & Sign-offs13
▸BISSCHEDULE A - OCCUPANCY / USE4
10/09/2013520126168Open ↗
09/19/2013520126168Open ↗
03/26/2013520126168Open ↗
Showing 3 of 4 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST4
01/11/2011520036648Open ↗
01/11/2011520012049Open ↗
12/28/2010520012049Open ↗
Showing 3 of 4 on file for this type
▸BISADMINISTRATIVE OBJECTIONS4
03/26/2013520126168Open ↗
05/13/2010520036648Open ↗
07/09/2009520012049Open ↗
Showing 3 of 4 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION1
07/14/2010520036648Open ↗
▸Cost, Insurance & Ownership6
▸BISCOST AFFIDAVIT6
03/26/2013520126168Open ↗
08/02/2011520036648Open ↗
01/11/2011520012049Open ↗
Showing 3 of 6 on file for this type
▸Filing & Intake Forms4
▸BISEFILING COVER SHEET3
03/26/2013520126168Open ↗
05/13/2010520036648Open ↗
07/09/2009520012049Open ↗
▸BISADDITIONAL INFORMATION1
08/02/2011520036648Open ↗
▸Other Documents5
▸DOB NOWProperty Ownership Certification2
08/13/2026S00785883-I1Open ↗
08/13/2026S00785883-P1Open ↗
▸BISPLOT DIAGRAM1
05/13/2010520036648Open ↗
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
07/14/2010520036648Open ↗
▸DOB NOWFinal Survey1